Facility ID: 9808080
Facility Name: WOMACK SANITATION INC
 
11/07/2024 Enforcement Tracking Activity Snyder, Ryan B
Activity Status: Open
08/24/2022 Violation Closed Kleinmann, Keith
Significance: Minor Status: Closed
Criteria ID: 7094
Rule: 62-762.711(1)
08/24/2022 Electronic Communication Activity Kleinmann, Keith
Activity Closed Date: 08/24/2022 Activity Status: Closed
Date: 08/24/2022
Recipient: billing@womacksanitation.com
Sender: Keith Kleinmann
Subject: Compliance inspection
Message: Schedule inspection
Events:
Event Type: Activity has been finished Date: 08/24/2022
Comment: Finished
08/24/2022 Enforcement Referral Activity Kleinmann, Keith
Activity Result: Accepted Activity Status: Closed
Activity Closed Date: 11/07/2024
Events:
Event Type: Activity/Document was acknowledged on this date Date: 09/02/2022
Comment: Acknowledged and Assigned by Rick R Roudebush
Events:
Event Type: Activity has been assigned Date: 09/02/2022
Comment: Assigned to Ryan B Snyder
Events:
Event Type: Activity has been submitted for approval Date: 08/26/2022
Comment: Submitted for approval by: Keith Kleinmann: N/A
Events:
Event Type: Activity has been finished Date: 11/07/2024
Comment: Finished
Events:
Event Type: Activity/Document was accepted on this date Date: 11/07/2024
Comment: Accepted by Ryan B Snyder: accept
Comments:
Comment Date: 08/26/2022 User: KLEINMANN_K_1
Description: N/A
Attachments:
Attachment Date: 08/26/2022 User: KLEINMANN_K_1
Description: G
View Attachment
Attachments:
Attachment Date: 08/26/2022 User: KLEINMANN_K_1
Description: History
View Attachment
Attachments:
Attachment Date: 08/24/2022 User: KLEINMANN_K_1
Description: Ref Ltr
View Attachment
08/24/2022 Violation Open Kleinmann, Keith
Significance: SNC-A Status: Open
Criteria ID: 7063
Rule: 62-762.601(1), 62-762.601(1)(a), 62-762.601(1)(b), 62-762.601(1)(c), 62-762.602(1), 62-762.602(1)(a), 62-762.602(1)(b), 62-762.602(1)(c)
08/10/2022 Site Inspection Activity Closed Kleinmann, Keith
Activity Result: Major Out of Compliance Activity Status: Closed
On-Site Start Date: 08/10/2022
Activity Closed Date: 08/24/2022 Activity Closed By: KLEINMANN_K_1
Events:
Event Type: Activity has been finished Date: 08/24/2022
Comment: Finished
Comments:
Comment Date: 08/24/2022 User: KLEINMANN_K_1
Description: TANKS: Consists of one 12,000-gallon double-walled, aboveground tank. Tank coating appears to be in satisfactory condition. No dripping/leaking issues were observed during the inspection. SPILL CONTAINMENT: - Tight fill, single-walled (SW) spill containment boxes located next to the tank, with a drain that was closed at time of inspection. No evidence of cracking or product/liquid observed during the inspection. The system is properly labeled. OVERFILL PROTECTION: – Equipped with an overfill prevention valve Morrison Clock Gauge with visual/audible alarm. The vents are present and observed to be in satisfactory condition. The alarm was tested and found to be nonfunctional. PIPING – Consists of a suction, steel/galvanized aboveground piping system with no contact with the soil. Except for minor corrosion, the aboveground piping was observed to be satisfactory condition. The piping is also equipped with solenoid/anti-siphon and manual isolation valves. Corrosion to metal components must be minimized by periodic maintenance. The facility conducts monthly visual inspections of visible/exposed tank components. HOSES/NOZZLES: The hoses and nozzles need to be changed. PLACARD: The Placard expiration date is: June 30, 2023. Storage tank registration fees are due to the Department each year by July 1. Ensure that your contact information is up-to-date with the Department in order to receive updates concerning your annual registration fees. Once fees are paid, you must print a copy of your placard from the Department's website: http://www.fldepportal.com/go/submit-registration/.
02/02/2021 Editable Letter Activity Kleinmann, Keith
Activity Title: In Compliance Letter Activity Status: Closed
Events:
Event Type: Activity has been finished Date: 02/02/2021
Comment: Finished
Attachments:
Attachment Date: 02/02/2021 User: KLEINMANN_K_1
Description: icl
View Attachment
12/22/2020 Electronic Communication Activity Kleinmann, Keith
Activity Closed Date: 12/22/2020 Activity Status: Closed
Date: 12/22/2020
Recipient: sara@womaksanitation.com
Sender: Keith Kleinmann
Subject: compliance inspection
Message: schedule inspection
Events:
Event Type: Activity has been finished Date: 12/22/2020
Comment: Finished
12/11/2020 Site Inspection Activity Closed Kleinmann, Keith
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 12/11/2020
Activity Closed Date: 12/22/2020 Activity Closed By: KLEINMANN_K_1
Events:
Event Type: Activity has been finished Date: 12/22/2020
Comment: Finished
Comments:
Comment Date: 12/11/2020 User: KLEINMANN_K_1
Description: Keith Kleinmann from Lee County met with your facility representative to conduct the Compliance Inspection of a fueling facility. TANKS: Consists of one 12,000-gallon double-walled, aboveground tank. Tank coating appears to be in satisfactory condition. No dripping/leaking issues were observed during the inspection. Tank interstitial is monitored via Krueger Leak Gauge. SPILL CONTAINMENT: - Tight fill, single-walled (SW) spill containment boxes located next to the tank, with a drain that was closed at time of inspection. No evidence of cracking or product/liquid observed during the inspection. The system is properly labeled. OVERFILL PROTECTION: – Equipped with an overfill prevention valve Morrison Clock Gauge with visual/audible alarm. The vents are present and observed to be in satisfactory condition. The alarm was tested and found to be nonfunctional. PIPING – Consists of a suction, steel/galvanized aboveground piping system with no contact with the soil. Except for minor corrosion, the aboveground piping was observed to be satisfactory condition. The piping is also equipped with solenoid/anti-siphon and manual isolation valves. Corrosion to metal components must be minimized by periodic maintenance. The facility conducts monthly visual inspections of visible/exposed tank components. HOSES/NOZZLES: The hoses and nozzles appear to be in satisfactory condition. PLACARD: The Placard expiration date is: June 30, 2021. Storage tank registration fees are due to the Department each year by July 1. Ensure that your contact information is up-to-date with the Department in order to receive updates concerning your annual registration fees. Once fees are paid, you must print a copy of your placard from the Department's website: http://www.fldepportal.com/go/submit-registration/. RECORDS SHALL BE KEPT FOR THREE YEARS IN ACCORDANCE WITH RULE 62-761.710, F.A.C. Inspection Report sent by e-mail to: sara@womaksanitation.com
03/09/2018 Editable Letter Activity Sautter, Mark Allen
Activity Title: In Compliance Letter Activity Status: Closed
Events:
Event Type: Activity has been submitted for approval Date: 03/09/2018
Comment: Submitted for approval by: Mark Allen Sautter
Events:
Event Type: Activity has been finished Date: 03/09/2018
Comment: Finished
Events:
Event Type: Activity/Document has been approved Date: 03/09/2018
Comment: Approved by Chris A. Zimmerman: Looks ok
Attachments:
Attachment Date: 03/09/2018 User: SAUTTER_MA_2
Description: ICL for inspection conducted on 03/07/2018
View Attachment
03/07/2018 Site Inspection Activity Closed Sautter, Mark Allen
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 03/07/2018
Activity Closed Date: 03/09/2018 Activity Closed By: SAUTTER_MA_2
Events:
Event Type: Activity has been finished Date: 03/09/2018
Comment: Finished
Events:
Event Type: Activity/Document has been approved Date: 03/09/2018
Comment: Approved by Chris A. Zimmerman: Looks ok
Events:
Event Type: Activity has been submitted for approval Date: 03/09/2018
Comment: Submitted for approval by: Mark Allen Sautter
Comments:
Comment Date: 03/07/2018 User: SAUTTER_MA_2
Description: Checked required documentation (Visuals, insurance, maintenance records, etc..) along with required storage tank components (Tanks, lines, spill buckets, hoses, etc...) Updated registration info as needed. Alarm/Maintenance History: Nothing significant to note.
01/15/2015 Site Inspection Activity Closed Johnson, Stephen G.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 01/15/2015
Activity Closed Date: 01/16/2015 Activity Closed By: JOHNSON_SG_1
Events:
Event Type: Activity has been finished Date: 01/16/2015
Comment: Finished
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Rwomackjr@womacksanitation.com
Comments:
Comment Date: 01/16/2015 User: JOHNSON_SG_1
Description: NOTES -Tank is equipped with old cork system interstitial gauge. While gauge is currently operational, it may be a good idea to have it replaced with a new plastic float gauge system.
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Alarm/Maintenance History -Nothing significant to note
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Checked all required documentation(monthly release detection records, maintenance records, RDRL, insurance, placard, testing, etc) along with storage tank components(tanks, piping, valves, tank interstitial, sensors, control panel, dispensers, alarms, etc).
01/15/2015 Site Inspection Activity Closed Johnson, Stephen G.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 01/15/2015
Activity Closed Date: 01/16/2015 Activity Closed By: JOHNSON_SG_1
Events:
Event Type: Activity has been finished Date: 01/16/2015
Comment: Finished
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Rwomackjr@womacksanitation.com
Comments:
Comment Date: 01/16/2015 User: JOHNSON_SG_1
Description: NOTES -Tank is equipped with old cork system interstitial gauge. While gauge is currently operational, it may be a good idea to have it replaced with a new plastic float gauge system.
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Alarm/Maintenance History -Nothing significant to note
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Checked all required documentation(monthly release detection records, maintenance records, RDRL, insurance, placard, testing, etc) along with storage tank components(tanks, piping, valves, tank interstitial, sensors, control panel, dispensers, alarms, etc).
01/15/2015 Site Inspection Activity Closed Johnson, Stephen G.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 01/15/2015
Activity Closed Date: 01/16/2015 Activity Closed By: JOHNSON_SG_1
Events:
Event Type: Activity has been finished Date: 01/16/2015
Comment: Finished
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Rwomackjr@womacksanitation.com
Comments:
Comment Date: 01/16/2015 User: JOHNSON_SG_1
Description: NOTES -Tank is equipped with old cork system interstitial gauge. While gauge is currently operational, it may be a good idea to have it replaced with a new plastic float gauge system.
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Alarm/Maintenance History -Nothing significant to note
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Checked all required documentation(monthly release detection records, maintenance records, RDRL, insurance, placard, testing, etc) along with storage tank components(tanks, piping, valves, tank interstitial, sensors, control panel, dispensers, alarms, etc).
01/15/2015 Site Inspection Activity Closed Johnson, Stephen G.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 01/15/2015
Activity Closed Date: 01/16/2015 Activity Closed By: JOHNSON_SG_1
Events:
Event Type: Activity has been finished Date: 01/16/2015
Comment: Finished
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Rwomackjr@womacksanitation.com
Comments:
Comment Date: 01/16/2015 User: JOHNSON_SG_1
Description: NOTES -Tank is equipped with old cork system interstitial gauge. While gauge is currently operational, it may be a good idea to have it replaced with a new plastic float gauge system.
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Alarm/Maintenance History -Nothing significant to note
Comments:
Comment Date: 01/15/2015 User: JOHNSON_SG_1
Description: Checked all required documentation(monthly release detection records, maintenance records, RDRL, insurance, placard, testing, etc) along with storage tank components(tanks, piping, valves, tank interstitial, sensors, control panel, dispensers, alarms, etc).
06/23/2011 Site Inspection Activity Closed Durrance, William K.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 06/23/2011
Activity Closed Date: 06/23/2011 Activity Closed By: DURRANCE_WK_1
Events:
Event Type: Activity has been finished Date: 06/23/2011
Comment: Finished
Comments:
Comment Date: 06/23/2011 User: DURRANCE_WK_1
Description: 1-12,000 gallon double walled AST. Using spill bucket, level gauges and alarms, flow shut off for overfill protection. Using monthly visual inspection, monitoring of double walled tank bottom space for release detection. CFR+FR-satisfactory RDRL-satisfactory Placard-satisfactory Monthly inspections-satisfactory Tank-satisfactory Tank interstice dry-satisfactory Spill bucket -satisfactory Overfill alarm-satisfactory Pumps-satisfactory All piping,hoses,and nozzles-satisfactory No evidence of discharge.
03/23/2010 Site Inspection Activity Closed Durrance, William K.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 03/23/2010
Activity Closed Date: 03/23/2010 Activity Closed By: DURRANCE_WK_1
Events:
Event Type: Activity has been finished Date: 03/23/2010
Comment: Finished
Comments:
Comment Date: 03/23/2010 User: DURRANCE_WK_1
Description: 1-12,000 gallon double walled AST. Using spill bucket, level gauges and alarms, flow shut off for overfill protection. Using monthly visual inspection, monitoring of double walled tank bottom space for release detection. CFR+FR-satisfactory RDRL-satisfactory Placard-satisfactory Monthly inspections-satisfactory Tank-satisfactory Tank interstice dry-satisfactory Spill bucket -satisfactory Overfill alarm-satisfactory Pumps-satisfactory All piping,hoses,and nozzles-satisfactory No evidence of discharge.
03/20/2009 Attachment Durrance, William K.
03/20/2009 Site Inspection Activity Closed Durrance, William K.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 03/20/2009
Activity Closed Date: 03/20/2009 Activity Closed By: DURRANCE_WK_1
Comments:
Comment Date: 03/20/2009 User: DURRANCE_WK_1
Description: 1-12,000 gallon double walled AST. Using spill bucket, level gauges and alarms, flow shut off for overfill protection. Using monthly visual inspection, monitoring of double walled interstitial space, tank bottom space for release detection. CFR+FR-satisfactory RDRL-satisfactory Placard-satisfactory exp. 6/30/09 Monthly inspections-satisfactory Tank-satisfactory Tank interstice dry-satisfactory Kruger gauge also used on interstice Spill bucket -satisfactory Overfill alarm-satisfactory Pumps-satisfactory All piping,hoses,and nozzles-satisfactory No evidence of discharge.
03/20/2009 Attachment Durrance, William K.
05/16/2008 Site Inspection Activity Closed Durrance, William K.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 05/16/2008
Activity Closed Date: 05/16/2008 Activity Closed By: DURRANCE_WK_1
Comments:
Comment Date: 05/16/2008 User: DURRANCE_WK_1
Description: 1-12,000 gallon double walled AST. Using spill bucket, level gauges and alarms, flow shut off for overfill protection. Using double walled tank space monitoring, monthly visual inspection for release detection. CFR+FR-satisfactory-expires 4/20/09 Placard-satisfactory-exp. 6/30/08 Monthly inspections-satisfactory RDRL-satisfactory Tank-satisfactory Kruger gauge EQ# 675 Spill bucket-satisfactory Overfill fill alarm-functioning properly. All piping, hoses, and nozzles-satisfactory *NOTE* A STRF needs to be submitted to change tank monitoring attributes. (STRF provided) No evidence of discharge.