Florida Department of Environmental Protection Bob Martinez Center 2600 Blair Stone Road Tallahassee, Florida 32399-2400 |
Storage Tanks & Contamination Monitoring Information |
|||||||||
Cover Page Report | |||||||||||
Report Run Date: 05/09/2025 Last Data Refresh: 05/08/2025 Report Generated from DOPPLER | |||||||||||
District | Northeast | Type | Retail Station | ||||||||
County | Clay | Status | OPEN | ||||||||
ID | 8503313 | Latitude | 29° 43' 15.4026 | ||||||||
Name |
NICKS KWIK STOP 8800 HWY 21 |
Longitude | 82° 2' 46.4432 | ||||||||
MELROSE, FL 32666 | LL Method | DGPS | |||||||||
Contact | WENDA LEWIS | LL Status | REVIEWED | ||||||||
Phone | Status Date | 10/30/2003 | |||||||||
Account Owner Information | |||||||||||
Name | LEWIS OIL CO INC PO BOX 141286 GAINESVILLE, FL 32614 |
Effective Date | 05/20/1994 | ||||||||
Contact | WENDA LEWIS (MGR) | ||||||||||
Phone | (352) 376-3293 | ||||||||||
WLEWIS@LEWISOILCO.COM | |||||||||||
Placard # / Date | 701579 - 10/02/2024 | ||||||||||
Property Owner Information | |||||||||||
Name | LEWIS OIL CO INC PO BOX 141286 GAINESVILLE, FL 32614 |
Effective Date | 07/18/2002 | ||||||||
Contact | WENDA LEWIS (MGR) | ||||||||||
Phone | (352) 376-3293 | ||||||||||
WLEWIS@LEWISOILCO.COM | |||||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
4 | 16000 | Unleaded Gas (B) | 05/01/2002 | UNDERGROUND | In Service (U) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (C) Steel (L) Compartmented (M) Spill containment bucket (O) Tight fill (R) Double wall - tank jacket |
(J) Pressurized piping system (K) Dispenser liners (M) Double wall - pipe jacket (N) Approved synthetic material |
(3) Electronic monitor pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (K) Monitor dbl wall pipe space (L) Automatic tank gauging - USTs |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
1 | 4000 | Unleaded Gas (B) | 08/01/1981 | UNDERGROUND | Removed from Site (B) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (B) Internal lining (C) Steel (M) Spill containment bucket |
(F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (H) Mechanical line leak detector (K) Monitor dbl wall pipe space (O) Vapor monitoring |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
2 | 8000 | Unleaded Gas (B) | 08/01/1981 | UNDERGROUND | Removed from Site (B) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (B) Internal lining (C) Steel (M) Spill containment bucket |
(D) External protective coating (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (H) Mechanical line leak detector (K) Monitor dbl wall pipe space (O) Vapor monitoring |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
3 | 3000 | Unleaded Gas (B) | 08/01/1981 | UNDERGROUND | Removed from Site (B) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (B) Internal lining (C) Steel (M) Spill containment bucket |
(D) External protective coating (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (H) Mechanical line leak detector (K) Monitor dbl wall pipe space (O) Vapor monitoring |
|||||||||
Insurance Documents | |||||||||||
FR Type | Effective Date | Expiration Date | Company Name | ||||||||
INSURANCE | 05/14/2022 | 05/14/2024 | SCOTTSDALE INSURANCE COMPANY | ||||||||
INSURANCE | 05/14/2020 | 05/14/2022 | ACE AMERICAN INSURANCE COMPANY | ||||||||
INSURANCE | 05/14/2020 | 05/14/2022 | SCOTTSDALE INSURANCE COMPANY | ||||||||
INSURANCE | 05/14/2019 | 05/14/2020 | ACE | ||||||||
INSURANCE | 05/14/2018 | 05/14/2019 | ILLINOIS UNION | ||||||||
INSURANCE | 05/14/2017 | 05/14/2018 | ACE | ||||||||
INSURANCE | 05/14/2016 | 05/14/2017 | AIG | ||||||||
INSURANCE | 01/31/2015 | 01/31/2016 | AIG | ||||||||
INSURANCE | 01/31/2015 | 05/14/2016 | ACE | ||||||||
INSURANCE | 01/31/2014 | 01/31/2015 | AIG | ||||||||
INSURANCE | 01/31/2013 | 01/31/2014 | CHARTIS SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 01/31/2012 | 01/31/2013 | CHARTIS SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 01/31/2011 | 01/31/2012 | CHARTIS SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 01/31/2011 | 01/31/2012 | CHEROKEE INSURANCE COMPANY | ||||||||
INSURANCE | 01/31/2010 | 01/31/2011 | CHARTIS SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 01/31/2010 | 01/31/2011 | CHARTIS SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 01/31/2009 | 01/31/2010 | AISLIC | ||||||||
INSURANCE | 01/31/2007 | 01/31/2008 | ZURICH-AMERICAN | ||||||||
Legacy Compliance Activity Information | |||||||||||
Activity Code |
Date Initiated |
Date Completed |
Results | Inspector | AST/UST Count |
Description | |||||
RRBD | 12/08/2005 | 12/09/2005 | BARNETT_P | 0/1 | COMPLIANCE ASSURANCE | ||||||
Completion Notes LD TEST 4/16/05 3/3 PASS | |||||||||||
TCI | 11/03/2005 | 11/16/2005 | MINOR OUT-OF-COMPLIANCE | BARNETT_P | 0/1 | COMPLIANCE ASSURANCE | |||||
Completion Notes ANNUAL OPERABILITY TEST 11/3/05 ALL SENSORS PASS | |||||||||||
RRBD | 11/23/2004 | 11/23/2004 | COMPLIANCE ASSURANCE | ||||||||
TCI | 10/21/2004 | 11/04/2004 | MINOR OUT-OF-COMPLIANCE | BARNETT_P | 0/1 | COMPLIANCE ASSURANCE | |||||
Completion Notes LEAK DETECTOR TEST 4/14/04 3/3 PASS | |||||||||||
RRBD | 11/20/2003 | 11/20/2003 | COMPLIANCE ASSURANCE | ||||||||
TCI | 09/04/2003 | 09/08/2003 | MINOR OUT-OF-COMPLIANCE | BARNETT_P | 0/2 | COMPLIANCE ASSURANCE | |||||
Completion Notes ANNUAL OPERABILITY 9/4/03 LD TEST 4/03 3/3 PASS | |||||||||||
RRBD | 09/30/2002 | 10/23/2002 | COMPLIANCE ASSURANCE | ||||||||
TCI | 08/27/2002 | 09/11/2002 | SIGNIFICANT OUT-OF-COMPLIANCE | BARNETT_P | 0/1 | COMPLIANCE ASSURANCE | |||||
TIN | 05/03/2002 | 06/04/2002 | IN-COMPLIANCE | BARNETT_P | 0/1 | COMPLIANCE ASSURANCE | |||||
Completion Notes INSTALL OF 1 DOUBLEWALL, COMPARTMENTED UST (GLASSTEEL II) PISCES PIPING/SUMPS TOTAL CONTAINMENT DISPENSER LINERS (EXISTING) | |||||||||||
TXI | 04/30/2002 | 06/04/2002 | IN-COMPLIANCE | BARNETT_P | 0/3 | COMPLIANCE ASSURANCE | |||||
Completion Notes CLOSURE OF TANKS / PIPING KEPT DISPENSER LINERS | |||||||||||
TCI | 08/14/2001 | 08/20/2001 | MINOR OUT-OF-COMPLIANCE | BARNETT_P | 0/3 | COMPLIANCE ASSURANCE | |||||
TCI | 08/22/2000 | 08/29/2000 | MINOR OUT-OF-COMPLIANCE | BARNETT_P | 0/3 | COMPLIANCE ASSURANCE | |||||
TCI | 08/18/1999 | 09/02/1999 | MINOR OUT-OF-COMPLIANCE | BARNETT_P | 0/3 | COMPLIANCE ASSURANCE | |||||
PDNE | 03/29/1999 | 03/29/1999 | BARNETT_P | 0/0 | COMPLIANCE ASSURANCE | ||||||
UTCI | 08/17/1998 | 09/03/1998 | MINOR OUT-OF-COMPLIANCE | COMPLIANCE ASSURANCE | |||||||
Compliance Activity Information | |||||||||||
Activity Code |
Date Completed |
Results | Inspector | AST/UST Count |
Description | ||||||
Letter | 10/02/2024 | Satisfied | MCNEIL_A | Enforcement | |||||||
Enforcement Referral | 08/12/2024 | Accepted | HARRINGTON_RD_1 | Enforcement | |||||||
Document Management | 05/06/2024 | Satisfied | HARRINGTON_RD_1 | Incident | |||||||
Site Inspection | 04/25/2024 | Minor Out of Compliance | HARRINGTON_RD_1 | 0/1 | Routine Compliance | ||||||
Electronic Communication | 04/25/2024 | Satisfied | HARRINGTON_RD_1 | Compliance Assistance | |||||||
Electronic Communication | 04/25/2024 | Satisfied | HARRINGTON_RD_1 | Compliance Assistance | |||||||
Electronic Communication | 04/25/2024 | Satisfied | HARRINGTON_RD_1 | Routine Compliance | |||||||
Letter | 04/25/2024 | Satisfied | HARRINGTON_RD_1 | Compliance Assistance | |||||||
Electronic Communication | 12/12/2021 | Satisfied | HARRINGTON_RD_1 | Routine Compliance | |||||||
Letter | 12/12/2021 | Satisfied | HARRINGTON_RD_1 | Routine Compliance | |||||||
Electronic Communication | 12/12/2021 | Satisfied | HARRINGTON_RD_1 | Compliance Assistance | |||||||
Site Inspection | 12/10/2021 | In Compliance | HARRINGTON_RD_1 | 0/1 | Routine Compliance | ||||||
Record Document | 10/01/2019 | Satisfied | HARRINGTON_RD_1 | Compliance Assistance | |||||||
Letter | 09/15/2019 | Satisfied | HARRINGTON_RD_1 | Compliance Assistance | |||||||
Electronic Communication | 09/15/2019 | Satisfied | HARRINGTON_RD_1 | Compliance Assistance | |||||||
Electronic Communication | 09/15/2019 | Satisfied | HARRINGTON_RD_1 | Routine Compliance | |||||||
Site Inspection | 09/10/2019 | Minor Out of Compliance | HARRINGTON_RD_1 | 0/1 | Routine Compliance | ||||||
Site Inspection | 05/19/2017 | In Compliance | HARRINGTON_RD_1 | 0/1 | Routine Compliance | ||||||
Site Inspection | 07/01/2014 | In Compliance | HARRINGTON_RD_1 | 0/1 | Routine Compliance | ||||||
Record Document | 01/30/2013 | Satisfied | HARRINGTON_RD_1 | Non-Compliance | |||||||
Emergency Preparedness Information | 01/25/2013 | Satisfied | HARRINGTON_RD_1 | Routine Compliance | |||||||
Site Inspection | 01/25/2013 | Minor Out of Compliance | HARRINGTON_RD_1 | 0/1 | Routine Compliance | ||||||
Electronic Communication | 01/25/2013 | Satisfied | HARRINGTON_RD_1 | Routine Compliance | |||||||
Letter | 01/25/2013 | Satisfied | HARRINGTON_RD_1 | Non-Compliance | |||||||
Site Inspection | 04/13/2011 | In Compliance | BARNETT_PC_1 | 0/1 | Routine Compliance | ||||||
Record Document | 10/29/2010 | Satisfied | HARRINGTON_RD_1 | Non-Compliance | |||||||
Letter | 06/16/2010 | Satisfied | BARNETT_PC_1 | Non-Compliance | |||||||
Site Inspection | 06/16/2010 | Minor Out of Compliance | BARNETT_PC_1 | 0/1 | Routine Compliance | ||||||
Record Document | 10/02/2007 | Satisfied | BARNETT_PC_1 | Non-Compliance | |||||||
Site Inspection | 09/19/2007 | In Compliance | BARNETT_PC_1 | 0/1 | Routine Compliance | ||||||
Letter | 09/19/2007 | Satisfied | BARNETT_PC_1 | Non-Compliance | |||||||
Record Document | 06/15/2007 | Satisfied | BARNETT_PC_1 | Non-Compliance | |||||||
Emergency Preparedness Information | 02/06/2007 | Satisfied | BARNETT_PC_1 | Routine Compliance | |||||||
Site Inspection | 11/16/2006 | Minor Out of Compliance | BARNETT_PC_1 | 0/1 | Routine Compliance | ||||||
Letter | 11/16/2006 | Satisfied | BARNETT_PC_1 | Non-Compliance | |||||||
Emergency Preparedness Information | 09/21/2006 | Satisfied | BARNETT_PC_1 | Routine Compliance | |||||||
No Open AOCs Found | |||||||||||
Open Violations | |||||||||||
Insp Date | Vio # | Significance | Violation Text | Corrective Action | |||||||
04/25/2024 | 6062 | Minor | 2.5 Release detection devices not tested annually. | Provide sensor and line leak detector test result documentation. | |||||||
04/25/2024 | 6074 | Minor | 2.8 Improper maintenance of records. Records requiring to be maintained for 3 years or for the life of the system not kept by facility. Records not provided within 5 business days. | Please maintain Veeder Root sensor status reports along with the monthly visual inspection documentation. This violation will be closed by inspector. | |||||||
04/25/2024 | 6053 | Minor | 4.7 Primary overfill protection not provided, registered, or tested as required. | Provide overfill prevention device test results. | |||||||
04/25/2024 | 6073 | Minor | 4.9 Spill containment, dispenser liners, and piping sumps not accessible. Water or regulated substances not removed. | Contact inspector for re-inspection. The dispenser liners must be accesessible. | |||||||
04/25/2024 | 6072 | Minor | 2.7 Integrity testing of secondary containment systems and interstitial spaces not performed per schedule. | Provide the Integrity Test result documentation for the single wall spill buckets, STP sumps and dispenser liners. | |||||||
04/22/2024 | 6073 | Minor | 4.9 Spill containment, dispenser liners, and piping sumps not accessible. Water or regulated substances not removed. | Remove fuel from the diesel STP sump. Dispose properly. Provide verification. | |||||||
04/22/2024 | 6009 | Minor | 4.1 Incident Notification Form (INF) not received in a timely manner. | File Incident Notification Form in regards to the fuel in the diesel STP sump. Investigate Incident to determine if a discharge has occurred (recommend hydro test of the sump and test of the chase pipe). Provide investigation results. | |||||||
04/22/2024 | 6066 | Minor | 4.4 Not repaired per applicable standards. | Perform hydrostatic test of the 87 spill bucket. Provide test result documentation. | |||||||
04/22/2024 | 6066 | Minor | 4.4 Not repaired per applicable standards. | Install break aways as required on dispenser hoses. Provide verification. | |||||||
No Discharges Found |