Florida Department of Environmental Protection Bob Martinez Center 2600 Blair Stone Road Tallahassee, Florida 32399-2400 |
Storage Tanks & Contamination Monitoring Information |
|||||
Cover Page Report | |||||||
Report Run Date: 05/17/2025 Last Data Refresh: 05/16/2025 Report Generated from DOPPLER | |||||||
District | Southwest | Type | Retail Station | ||||
County | Pinellas | Status | OPEN | ||||
ID | 8515481 | Latitude | 27° 56' 7.6211 | ||||
Name |
ROYAL SERVICE CNTR 1698 CLEARWATER LARGO RD |
Longitude | 82° 47' 45.1394 | ||||
CLEARWATER, FL 33756-1107 | LL Method | DPHO | |||||
Contact | ATEF REZKALLA | LL Status | REVIEWED | ||||
Phone | (727) 586-4544 | Status Date | 09/09/2003 | ||||
Account Owner Information | |||||||
Name | ROYAL SERVICES CNTR 1698 CLEARWATER LARGO RD CLEARWATER, FL 33756 |
Effective Date | 06/28/2013 | ||||
Contact | ATEF REZKALLA | ||||||
Phone | (727) 251-6345 | ||||||
KABGROUP@YAHOO.COM | |||||||
Placard # / Date | 682532 - 06/05/2024 | ||||||
No Property Owner Information Found | |||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
3 | 10000 | Unleaded Gas (B) | 03/01/1996 | UNDERGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(A) Ball check valve (C) Steel (M) Spill containment bucket (O) Tight fill (R) Double wall - tank jacket |
(F) Double wall (J) Pressurized piping system (K) Dispenser liners (N) Approved synthetic material |
(3) Electronic monitor pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (K) Monitor dbl wall pipe space |
|||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
4 | 10000 | Unleaded Gas (B) | 03/01/1996 | UNDERGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(A) Ball check valve (C) Steel (M) Spill containment bucket (O) Tight fill (R) Double wall - tank jacket |
(F) Double wall (J) Pressurized piping system (K) Dispenser liners (N) Approved synthetic material |
(3) Electronic monitor pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (K) Monitor dbl wall pipe space |
|||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
1 | 10000 | Unleaded Gas (B) | 05/01/1981 | UNDERGROUND | Removed from Site (B) | ||
Constructions | Pipings | Monitorings | |||||
(C) Steel (M) Spill containment bucket (O) Tight fill |
(B) Steel/galvanized metal (I) Suction piping system |
(8) Manually sampled wells (M) Manual tank gauging - USTs |
|||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
2 | 4000 | Unleaded Gas (B) | 05/01/1981 | UNDERGROUND | Removed from Site (B) | ||
Constructions | Pipings | Monitorings | |||||
(C) Steel | (C) Fiberglass | (8) Manually sampled wells | |||||
Insurance Documents | |||||||
FR Type | Effective Date | Expiration Date | Company Name | ||||
INSURANCE | 10/04/2018 | 10/04/2019 | ACE AMERICAN INSURANCE COMPANY | ||||
INSURANCE | 10/04/2017 | 10/04/2018 | ACE AMERICAN INSURANCE COMPANY | ||||
INSURANCE | 10/04/2016 | 10/04/2017 | ACE AMERICAN INSURANCE COMPANY | ||||
INSURANCE | 10/04/2013 | 10/04/2014 | ACE | ||||
INSURANCE | 10/04/2012 | 10/04/2013 | ACE | ||||
INSURANCE | 10/04/2011 | 10/04/2012 | ACE | ||||
INSURANCE | 07/07/2010 | 07/07/2011 | ACE | ||||
INSURANCE | 05/21/2008 | 05/21/2009 | ZURICH-AMERICAN | ||||
INSURANCE | 02/16/1990 | 02/16/1996 | FPLIPA | ||||
Legacy Compliance Activity Information | |||||||
Activity Code |
Date Initiated |
Date Completed |
Results | Inspector | AST/UST Count |
Description | |
NCLI | 02/28/2006 | 02/28/2006 | BARNETT | 0/2 | COMPLIANCE ASSURANCE | ||
TCI | 02/28/2006 | 02/28/2006 | SIGNIFICANT OUT-OF-COMPLIANCE | BARNETT | 0/2 | COMPLIANCE ASSURANCE | |
TCI | 05/04/2005 | 05/05/2005 | IN-COMPLIANCE | BARNETT | 0/2 | COMPLIANCE ASSURANCE | |
LTR | 05/04/2005 | 05/05/2005 | BARNETT | 0/0 | COMPLIANCE ASSURANCE | ||
NCLI | 06/23/2004 | 06/30/2004 | FRAZIER | 0/0 | COMPLIANCE ASSURANCE | ||
TCI | 06/23/2004 | 06/30/2004 | MINOR OUT-OF-COMPLIANCE | FRAZIER | 0/2 | COMPLIANCE ASSURANCE | |
Completion Notes AMERON DW FRP PIPE | |||||||
SCOE | 03/29/2004 | 05/04/2004 | LEWIS | 0/0 | COMPLIANCE ASSURANCE | ||
FR | 02/20/2004 | 02/20/2004 | SOWERS | 0/0 | COMPLIANCE ASSURANCE | ||
Completion Notes DATA CLEAN UP ACTIVITY PER FDEP REQUEST | |||||||
EMT | 08/21/2003 | 08/21/2003 | LEWIS_J | 0/0 | COMPLIANCE ASSURANCE | ||
WLI | 06/25/2003 | 06/26/2003 | LEWIS_J | 0/0 | COMPLIANCE ASSURANCE | ||
NCLI | 03/06/2003 | 03/06/2003 | TAM | 0/0 | COMPLIANCE ASSURANCE | ||
TCI | 03/04/2003 | 03/06/2003 | SIGNIFICANT OUT-OF-COMPLIANCE | TAM | 0/2 | COMPLIANCE ASSURANCE | |
Completion Notes AMERON FRP DW PIPING, MECHANICAL LLD, TCI JACKETED TANK, VEEDER ROOT TLS350 | |||||||
LTR | 02/17/2003 | 02/19/2003 | HALSCOTT | 0/0 | COMPLIANCE ASSURANCE | ||
TIN | 02/05/2003 | 02/19/2003 | IN-COMPLIANCE | HALSCOTT | 0/2 | COMPLIANCE ASSURANCE | |
Completion Notes DW AMERON RED THREAD FRP PIPE | |||||||
LTR | 11/04/2002 | 11/06/2002 | HALSCOTT | 0/0 | DISCHARGE PROJECT | ||
SV | 10/03/2002 | 03/07/2003 | TAM | 0/0 | COMPLIANCE ASSURANCE | ||
NCLI | 09/23/2002 | 11/06/2002 | HALSCOTT | 0/0 | DISCHARGE PROJECT | ||
TCI | 05/29/2002 | 05/31/2002 | SIGNIFICANT OUT-OF-COMPLIANCE | STRAUSS | 0/2 | COMPLIANCE ASSURANCE | |
TCI | 08/22/2000 | 09/05/2000 | MINOR OUT-OF-COMPLIANCE | HALSCOTT | 0/2 | COMPLIANCE ASSURANCE | |
RRBD | 08/21/2000 | 09/08/2000 | SOWERS | 0/0 | COMPLIANCE ASSURANCE | ||
RRBD | 05/12/2000 | 07/12/2000 | HALSCOTT | 0/0 | COMPLIANCE ASSURANCE | ||
TCI | 04/27/2000 | 05/01/2000 | SIGNIFICANT OUT-OF-COMPLIANCE | HALSCOTT | 0/2 | COMPLIANCE ASSURANCE | |
UTCI | 02/20/1997 | 02/20/1997 | MINOR OUT-OF-COMPLIANCE | COMPLIANCE ASSURANCE | |||
Completion Notes Routine, | |||||||
Compliance Activity Information | |||||||
Activity Code |
Date Completed |
Results | Inspector | AST/UST Count |
Description | ||
Enforcement Tracking | 12/17/2024 | Closed Without Enforcement | PEDIGO_L | Enforcement | |||
Enforcement Referral | 06/19/2024 | Accepted | MUSLIC_A_1 | Enforcement | |||
Site Inspection | 03/26/2024 | Major Out of Compliance | MUSLIC_A_1 | 0/2 | Routine Compliance | ||
Electronic Communication | 03/12/2024 | Satisfied | MUSLIC_A_1 | Routine Compliance | |||
Letter | 03/28/2022 | Satisfied | SHOCK_E_1 | Non-Compliance | |||
Site Inspection | 03/25/2022 | Major Out of Compliance | SHOCK_E_1 | 0/2 | Routine Compliance | ||
Electronic Communication | 03/08/2022 | Satisfied | SHOCK_E_1 | Routine Compliance | |||
Electronic Communication | 10/23/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/23/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Phone Conversation | 10/23/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/23/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/22/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/22/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/22/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/21/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/21/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/21/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Meeting | 10/20/2020 | Satisfied | PEDIGO_L | Enforcement | |||
Letter | 04/22/2019 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||
Site Inspection | 04/22/2019 | Major Out of Compliance | STRAUSS_RH_1 | 0/2 | Routine Compliance | ||
Electronic Communication | 03/12/2019 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||
Electronic Communication | 10/29/2018 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||
Phone Conversation | 08/08/2018 | Satisfied | PEDIGO_L | Enforcement | |||
Electronic Communication | 08/01/2018 | Satisfied | PEDIGO_L | Enforcement | |||
Record Document | 01/04/2017 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
Record Document | 01/04/2017 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
Enforcement Referral | 12/07/2016 | Accepted | STRAUSS_RH_1 | Enforcement | |||
Letter | 11/16/2016 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
Electronic Communication | 11/16/2016 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
Electronic Communication | 11/16/2016 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
Letter | 07/29/2016 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
Site Inspection | 07/29/2016 | Major Out of Compliance | STRAUSS_RH_1 | 0/2 | Routine Compliance | ||
Electronic Communication | 07/12/2016 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||
Discharge Reporting | 06/19/2015 | Satisfied | SOWERS_JA_1 | Discharge | |||
Site Inspection | 04/25/2014 | In Compliance | COLSON_NJ_1 | 0/2 | Non-Compliance | ||
Issue Document | 04/25/2014 | Satisfied | COLSON_NJ_1 | Non-Compliance | |||
Letter | 03/24/2014 | Satisfied | COLSON_NJ_1 | Non-Compliance | |||
Site Inspection | 03/24/2014 | Minor Out of Compliance | COLSON_NJ_1 | 0/2 | Routine Compliance | ||
Record Document | 08/27/2013 | Satisfied | JUEDES_HC_1 | Non-Compliance | |||
Record Document | 06/13/2013 | Satisfied | JUEDES_HC_1 | Non-Compliance | |||
Letter | 06/11/2013 | Satisfied | JUEDES_HC_1 | Non-Compliance | |||
Electronic Communication | 06/11/2013 | Satisfied | JUEDES_HC_1 | Non-Compliance | |||
Site Inspection | 06/11/2013 | Major Out of Compliance | JUEDES_HC_1 | 0/2 | Non-Compliance | ||
Letter | 05/01/2013 | Satisfied | JUEDES_HC_1 | Non-Compliance | |||
Electronic Communication | 05/01/2013 | Satisfied | JUEDES_HC_1 | Non-Compliance | |||
Site Inspection | 04/30/2013 | Major Out of Compliance | JUEDES_HC_1 | 0/2 | Routine Compliance | ||
Emergency Preparedness Information | 04/29/2013 | Satisfied | JUEDES_HC_1 | Routine Compliance | |||
TCAR | 10/01/2012 | Satisfied | LONGEN_JL_1 | Closure | |||
Record Document | 08/28/2012 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Site Inspection | 08/07/2012 | Major Out of Compliance | LONGEN_JL_1 | 0/2 | Non-Compliance | ||
Letter | 08/07/2012 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Enforcement Tracking | 08/02/2012 | Closed Without Enforcement | PEDIGO_L | Enforcement | |||
Site Inspection | 10/05/2011 | Major Out of Compliance | LONGEN_JL_1 | 0/2 | Routine Compliance | ||
Letter | 10/05/2011 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Enforcement Referral | 10/04/2011 | Accepted | PEDIGO_L | Enforcement | |||
Record Document | 03/30/2011 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Site Inspection | 02/28/2011 | Major Out of Compliance | LONGEN_JL_1 | 0/2 | Non-Compliance | ||
Letter | 02/28/2011 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Letter | 02/10/2011 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
Letter | 11/17/2010 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Site Inspection | 11/17/2010 | Major Out of Compliance | LONGEN_JL_1 | 0/2 | Routine Compliance | ||
Emergency Preparedness Information | 11/16/2010 | Satisfied | LONGEN_JL_1 | Routine Compliance | |||
Electronic Communication | 05/12/2010 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Record Document | 05/04/2010 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
Document Management | 01/28/2010 | Complete | SOWERS_JA_1 | Closure | |||
Letter | 01/28/2010 | Major Out of Compliance | SOWERS_JA_1 | Discharge | |||
Letter | 01/28/2010 | Major Out of Compliance | SOWERS_JA_1 | Closure | |||
Record Document | 01/28/2010 | Major Out of Compliance | SOWERS_JA_1 | Discharge | |||
Site Inspection | 01/05/2010 | Major Out of Compliance | LONGEN_JL_1 | 0/2 | Installation | ||
Letter | 01/05/2010 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Site Inspection | 12/29/2009 | Major Out of Compliance | LONGEN_JL_1 | 0/2 | Closure | ||
Letter | 12/29/2009 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Letter | 12/22/2009 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Site Inspection | 12/22/2009 | Major Out of Compliance | LONGEN_JL_1 | 0/2 | Routine Compliance | ||
Site Inspection | 03/26/2009 | In Compliance | LONGEN_JL_1 | 0/2 | Non-Compliance | ||
Emergency Preparedness Information | 12/09/2008 | Satisfied | LONGEN_JL_1 | Routine Compliance | |||
Letter | 12/09/2008 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||
Site Inspection | 12/09/2008 | Minor Out of Compliance | LONGEN_JL_1 | 0/2 | Routine Compliance | ||
Site Inspection | 04/25/2008 | In Compliance | BARNETT_JX | 0/2 | Non-Compliance | ||
Record Document | 04/24/2008 | Satisfied | BARNETT_JX | Non-Compliance | |||
Record Document | 03/25/2008 | Satisfied | BARNETT_JX | Non-Compliance | |||
Site Inspection | 12/24/2007 | Major Out of Compliance | BARNETT_JX | 0/2 | Routine Compliance | ||
Letter | 12/24/2007 | Satisfied | BARNETT_JX | Non-Compliance | |||
Letter | 03/27/2007 | Satisfied | BARNETT_JX | Non-Compliance | |||
Site Inspection | 03/27/2007 | Minor Out of Compliance | BARNETT_JX | 0/2 | Routine Compliance | ||
Emergency Preparedness Information | 02/05/2007 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||
TCAR | 12/01/2006 | Satisfied | SOWERS_JA_1 | Closure | |||
Emergency Preparedness Information | 09/19/2006 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||
Meeting | 06/28/2006 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||
No Open AOCs Found | |||||||
Open Violations | |||||||
Insp Date | Vio # | Significance | Violation Text | Corrective Action | |||
03/26/2024 | 6073 | Minor | 4.9 Spill containment, dispenser liners, and piping sumps not accessible. Water or regulated substances not removed. | Make repairs to RUL spill bucket dipstick (remove dipstick) and inspect secondary spill bucket; if liquid is present, remove, dispose of, and test spill bucket. Provide results. | |||
03/26/2024 | 6074 | Minor | 2.8 Improper maintenance of records. Records requiring to be maintained for 3 years or for the life of the system not kept by facility. Records not provided within 5 business days. | Please ensure all required records are available within 5 days notice. | |||
03/25/2024 | 6065 | SNC-B | 4.3 Damaged system not taken out of service or out of operation until repair is made. | Repair or replace electrical conduit box in PUL STP sump. | |||
03/25/2024 | 6015 | Minor | 4.3 Incident investigation not completed within 14 days, and/or no DRF or written confirmation received at the end of the 14-day investigation period. | Please place both tanks out-of-service until the incident is investigated and a report submitted to the Pinellas tank program office. | |||
03/25/2024 | 6068 | SNC-B | 4.6 Storage tank system not closed within 90 days in accordance with subsection. | Please place both tanks out-of-service. If not repaired within 365 days after being taken out-of-service, the tanks shall be permanently closed. | |||
03/25/2024 | 6064 | SNC-A | 4.2 Not repaired or isolated component or piping which has cause a discharge or release. | Repair/replace piping to stop the leaks and submit the proof of compliance. | |||
03/25/2024 | 6038 | SNC-B | 4.9 Shear valve not installed properly. | Repair/replace anchoring mechanism to rigidly anchor the valves independently of the dispensers. | |||
03/25/2024 | 6014 | SNC-B | 4.2 Incident investigation not initiated within 24-hours (or by next business day) to determine if discharge occurred. | Please submit a completed INF to report the alarm, investigate and correct as necessary. | |||
03/25/2022 | 6012 | SNC-A | 2.9 No financial responsibility instrument or expired instrument for > 180 days. | Financial responsibility shall be maintained and demonstrated to the county or Department for all storage tank systems until the storage tank systems are properly closed. Due to the lack of financial responsibility / insurance policy for a period greater than 180 days, the tanks must be closed. | |||
03/23/2022 | 6073 | Minor | 4.9 Spill containment, dispenser liners, and piping sumps not accessible. Water or regulated substances not removed. | Make repairs to RUL spill bucket dipstick (remove dipstick), and inspect secondary spill bucket; if liquid is present, remove, dispose of, and test spill bucket. Provide results. At the PUL spill bucket, investigate red/test indicator for secondary, if liquid is present, remove, dispose of, and test spill bucket. Provide results. | |||
03/23/2022 | 6009 | Minor | 4.1 Incident Notification Form (INF) not received in a timely manner. | Complete an investigation and make repairs as necessary at the spill buckets. Perform integrity testing of the spill buckets and provide results. | |||
04/22/2019 | 4001 | Minor | 2.2 Operator certification requirements not met. | Please provide A/B certificate for the owner and C certificates for all personnel responsible for the operation of the tank systems while the facility is open | |||
04/22/2019 | 4007 | Minor | 2.6 Registration fees not paid, placard not posted. | Please post the placard in a visible location at the facility | |||
04/22/2019 | 4016 | SNC-B | 2.5 Incident investigation not initiated within 24-hours of discovery. | Please submit a completed INF to report the alarm, investigate and correct as necessary | |||
04/22/2019 | 4077 | Minor | 4.12 Spill containment, sumps, and interstices not accessible. Water/regulated substances not timely removed. Petroleum contact water not properly managed. | Please remove liquid from units and provide documentation of its proper disposal; provide access for inspection of spill bucket secondary spaces | |||
04/22/2019 | 4076 | Minor | 4.11 Failure to conduct required periodic containment and interstitial integrity testing. | Please provide current test results and ensure these units are tested every 3 years therafter | |||
04/22/2019 | 4067 | Minor | 4.2 Release detection devices not tested annually. | Please provide current test results and ensure these devices are tested annually at intervals not exceeding 12 months | |||
04/22/2019 | 4057 | Minor | 4.31 Overfill protection devices not registered or tested annually. | Please provide current test results and ensure these devices are tested annually at intervals not exceeding 12 months | |||
04/22/2019 | 4068 | Minor | 4.3 Storage tank system has a not repaired component which has or could cause a release or discharge. | Please remark cover in accordance with API 1637 to indicate the product stored; please test the Premium sump sensor and repair or replace as necessary | |||
04/22/2019 | 4017 | Minor | 2.6 Incident investigation not completed timely, with written explanation or DRF provided. | Please place the Regular tank out-of-service until the incident is investigated and a report submitted to the Pinellas tank program office | |||
04/22/2019 | 4060 | Minor | 4.5 Release detection not installed, operated, and maintained per manufacturer's instructions and standards. | Please install sensor on sump bottom | |||
07/29/2016 | 1063 | Minor | 4.49 Continuous electronic leak detection not inspected monthly. | Please provide the past two years monthly release detection records | |||
07/29/2016 | 1123 | Minor | 2.14 Records requiring 2 year documentation period not kept by facility. | Please ensure all required records are kept for a minimum period of two years | |||
07/29/2016 | 1122 | Minor | 2.13 Permanent records not available within 5 working-days notice; no reasonable facility access. | Please ensure all required records are available within 5 days notice | |||
07/29/2016 | 1062 | SNC-B | 4.48 Release detection not performed at least once a month. | Please provide the past two years of monthly release detection inspection records | |||
Discharge Information | |||||||
Discharge Date |
Clean Up Status |
Score | Eligibility Info | Site Manager | Phone | ||
01/04/2010 | COMPLETED | 60 | |||||
01/04/1996 | COMPLETED | 56 | |||||
05/02/1986 | COMPLETED | 56 | EARLY DETECTION INCENTIVE-ELIGIBLE | ||||