DEP Logo Florida Department of
Environmental Protection


Bob Martinez Center
2600 Blair Stone Road
Tallahassee, Florida 32399-2400
Storage Tanks &
Contamination
Monitoring Information
 
Cover Page Report
Report Run Date: 05/09/2025        Last Data Refresh: 05/08/2025        Report Generated from DOPPLER
 
District Northwest   Type    Retail Station
 
County Santa Rosa   Status    OPEN
 
ID 8516397   Latitude    30° 35' 58.9183
 
Name CIRCLE K #2704963
3900 US HWY 90
Longitude    87° 9' 39.0765
  PACE, FL 32571 LL Method    DPHO
 
Contact FRAN FRANCONI   LL Status    REVIEWED
 
Phone (813) 910-6884   Status Date    06/30/2015
 
Account Owner Information
 
Name CIRCLE K STORES INC
25 W CEDAR ST STE M
Pensacola, FL 32502
Effective Date    01/13/2010
 
Contact IRA LEWIS/ SCOTT JANASHAK / DEBORAH BRATTON
 
Phone (850) 454-1070
 
Email ILEWIS@CIRCLEK.COM
  Placard # / Date    697399 - 06/28/2024
Property Owner Information
 
Name CIRCLE K STORES INC
25 W CEDAR ST STE M
Pensacola, FL 32502
Effective Date    01/13/2010
 
Contact IRA LEWIS/ SCOTT JANASHAK / DEBORAH BRATTON
 
Phone (850) 454-1070
 
Email ILEWIS@CIRCLEK.COM
 
 
 
 
 
 
 
 
 
Tank Tank Size Content Installed Placement Status
10 20000 Ethanol E10 (8) 06/01/2020 UNDERGROUND In Service (U)
 
Constructions   Pipings Monitorings
(E) Fiberglass
(I) Double wall
(L) Compartmented
(M) Spill containment bucket
(N) Flow shut-Off
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(P) Internal pipe/internal sump riser
(3) Electronic monitor pipe sumps
(5) Electronic monitor dispenser liners
(F) Monitor dbl wall tank space
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
 
 
Tank Tank Size Content Installed Placement Status
11 12000 Vehicular Diesel (D) 06/01/2020 UNDERGROUND In Service (U)
 
Constructions   Pipings Monitorings
(E) Fiberglass
(I) Double wall
(M) Spill containment bucket
(N) Flow shut-Off
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(P) Internal pipe/internal sump riser
(3) Electronic monitor pipe sumps
(5) Electronic monitor dispenser liners
(F) Monitor dbl wall tank space
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
 
 
Tank Tank Size Content Installed Placement Status
9 20000 Ethanol E10 (8) 06/01/2020 UNDERGROUND In Service (U)
 
Constructions   Pipings Monitorings
(E) Fiberglass
(I) Double wall
(M) Spill containment bucket
(N) Flow shut-Off
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(P) Internal pipe/internal sump riser
(3) Electronic monitor pipe sumps
(5) Electronic monitor dispenser liners
(F) Monitor dbl wall tank space
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
 
 
Tank Tank Size Content Installed Placement Status
1 3000 Kerosene (K) 09/01/1983 ABOVEGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(D) Unknown   (Y) Unknown (Y) Unknown
 
 
Tank Tank Size Content Installed Placement Status
1R1 10000 Unleaded Gas (B) 09/01/1988 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(F) Fiberglass clad steel
(M) Spill containment bucket
(O) Tight fill
  (B) Steel/galvanized metal
(E) Cathodic protection
(J) Pressurized piping system
(K) Dispenser liners
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(S) Statistical Inventory Reconcile
 
 
Tank Tank Size Content Installed Placement Status
2 2000 Vehicular Diesel (D) 09/01/1983 ABOVEGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(D) Unknown   (Y) Unknown (Y) Unknown
 
 
Tank Tank Size Content Installed Placement Status
2R1 10000 Unleaded Gas (B) 09/01/1988 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(F) Fiberglass clad steel
(M) Spill containment bucket
(O) Tight fill
  (B) Steel/galvanized metal
(E) Cathodic protection
(J) Pressurized piping system
(K) Dispenser liners
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(S) Statistical Inventory Reconcile
 
 
Tank Tank Size Content Installed Placement Status
3 1000 Vehicular Diesel (D) 07/01/1979 ABOVEGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(D) Unknown   (C) Fiberglass (8) Manually sampled wells
 
 
Tank Tank Size Content Installed Placement Status
3R1 10000 Unleaded Gas (B) 09/01/1988 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(F) Fiberglass clad steel
(M) Spill containment bucket
(O) Tight fill
  (B) Steel/galvanized metal
(E) Cathodic protection
(J) Pressurized piping system
(K) Dispenser liners
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(S) Statistical Inventory Reconcile
 
 
Tank Tank Size Content Installed Placement Status
4 4000 Leaded Gas (A) 07/01/1979 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(C) Steel
  (C) Fiberglass (8) Manually sampled wells
 
 
Tank Tank Size Content Installed Placement Status
4R1 4000 Vehicular Diesel (D) 09/01/1988 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(F) Fiberglass clad steel
(M) Spill containment bucket
(O) Tight fill
  (B) Steel/galvanized metal
(E) Cathodic protection
(J) Pressurized piping system
(K) Dispenser liners
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(S) Statistical Inventory Reconcile
 
 
Tank Tank Size Content Installed Placement Status
5 2000 Unleaded Gas (B) 07/01/1979 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(C) Steel
  (C) Fiberglass (8) Manually sampled wells
 
 
Tank Tank Size Content Installed Placement Status
5R1 4000 Kerosene (K) 09/01/1988 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(F) Fiberglass clad steel
(M) Spill containment bucket
(O) Tight fill
  (B) Steel/galvanized metal
(E) Cathodic protection
(J) Pressurized piping system
(K) Dispenser liners
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(S) Statistical Inventory Reconcile
 
 
Tank Tank Size Content Installed Placement Status
6 4000 Unleaded Gas (B) 07/01/1979 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(C) Steel
  (C) Fiberglass (8) Manually sampled wells
 
 
Tank Tank Size Content Installed Placement Status
7 1000 Kerosene (K) 07/01/1979 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(C) Steel   (C) Fiberglass (8) Manually sampled wells
 
 
Tank Tank Size Content Installed Placement Status
8 30000 Unleaded Gas (B) 03/01/2010 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(F) Fiberglass clad steel
(I) Double wall
(M) Spill containment bucket
(O) Tight fill
(P) Level gauges/alarms
  (F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(N) Approved synthetic material
(1) Continuous electronic sensing
(2) Visual inspect pipe sumps
(3) Electronic monitor pipe sumps
(4) Visual inspect dispenser liners
(5) Electronic monitor dispenser liners
(F) Monitor dbl wall tank space
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(L) Automatic tank gauging - USTs
 
 
Insurance Documents
 
FR Type   Effective Date Expiration Date Company Name
GUARANTEE   04/30/2023 08/28/2024
GUARANTEE   04/25/2021 08/27/2022
INSURANCE   12/01/2019 12/01/2020 IRONSHORE SPECIALTY INSURANCE CO
INSURANCE   12/01/2018 12/01/2019 IRONSHORE SPECIALTY INSURANCE CO
INSURANCE   12/01/2017 12/01/2018 IRONSHORE SPECIALTY INSURANCE CO
INSURANCE   12/01/2016 12/01/2017 IRONSHORE SPECIALTY INSURANCE CO
INSURANCE   12/01/2013 12/01/2016 IRONSHORE SPECIALTY INSURANCE CO
INSURANCE   12/01/2011 12/01/2013 CHUBB
INSURANCE   12/17/2009 12/01/2011 CHUBB
INSURANCE   12/17/2008 12/17/2009 AMERICAN INTERNATIONAL SPECIALTY LINES
INSURANCE   12/17/2007 12/17/2008 AMERICAN INTERNATIONAL SPECIALTY LINES
 
 
Legacy Compliance Activity Information
 
Activity
Code
Date
Initiated
Date
Completed
Results Inspector AST/UST
Count
Description
TCI 12/15/2005 12/20/2005 IN-COMPLIANCE JOSEPH D. THAYER 0/5 COMPLIANCE ASSURANCE
 
 Completion Notes NO VIOLATIONS NOTED THIS INSPECTION
 
TIN 04/14/2005 04/15/2005 IN-COMPLIANCE JOSEPH D. THAYER 0/5 COMPLIANCE ASSURANCE
 
 Completion Notes THIS INSPECTION COVERS THE REPLACEMENT OF 5 DEFECTIVE SPILL CONTAINMENT BUCKETS. PANHANDLE PUMP PERFORMED WORK. NEW BUCKETS UNIVERSAL VALVE COMPANY MODEL 70C - EQ298.
 
TXI 04/13/2005 04/19/2005 IN-COMPLIANCE JOSEPH D. THAYER 0/5 COMPLIANCE ASSURANCE
 
 Completion Notes REMOVAL OF 5 OLD OPW SPILL BUCKETS. PANHANDLE PUMP PCC045053. DRF SUBMITTED 3/25/05.
 
TCI 11/09/2004 11/10/2004 IN-COMPLIANCE JOSEPH D. THAYER 0/5 COMPLIANCE ASSURANCE
 
TCI 12/18/2003 12/29/2003 IN-COMPLIANCE JOSEPH D. THAYER 0/5 COMPLIANCE ASSURANCE
 
TCI 02/25/2003 03/03/2003 IN-COMPLIANCE REGINALD W. BRADLEY 0/5 COMPLIANCE ASSURANCE
 
TCI 04/18/2002 04/22/2002 IN-COMPLIANCE V. PAUL HUTCHERSON 0/5 COMPLIANCE ASSURANCE
 
TCI 01/25/2001 02/13/2001 IN-COMPLIANCE STEVENSON_JS 0/3 COMPLIANCE ASSURANCE
 
RRBD 05/02/2000 05/30/2000 STEVENSON_JS 0/0 COMPLIANCE ASSURANCE
 
TCI 03/17/2000 03/30/2000 MINOR OUT-OF-COMPLIANCE STEVENSON_JS 0/5 COMPLIANCE ASSURANCE
 
RRBD 02/04/1999 03/29/1999 STEVENSON_J 0/0 COMPLIANCE ASSURANCE
 
TCI 01/15/1999 03/16/1999 MINOR OUT-OF-COMPLIANCE JOHN S. STEVENSON 0/5 COMPLIANCE ASSURANCE
 
NCLI 11/30/1998 03/29/1999 STEVENSON_J 0/0 COMPLIANCE ASSURANCE
 
UTII 09/10/1998 10/13/1998 MINOR OUT-OF-COMPLIANCE COMPLIANCE ASSURANCE
 
 
 
Compliance Activity Information
 
Activity
Code
Date
Completed
Results Inspector AST/UST
Count
Description
Enforcement Referral 06/26/2024 Accepted PAYNE_CL_1 Enforcement
 
Record Document 06/24/2024 Satisfied PAYNE_CL_1 Compliance Assistance
 
Record Document 06/24/2024 Satisfied PAYNE_CL_1 Compliance Assistance
 
Record Document 06/24/2024 Satisfied PAYNE_CL_1 Compliance Assistance
 
Site Inspection 03/11/2024 Major Out of Compliance PAYNE_CL_1 0/3 Routine Compliance
 
Letter 03/11/2024 Satisfied PAYNE_CL_1 Compliance Assistance
 
Electronic Communication 03/08/2024 Satisfied PAYNE_CL_1 Routine Compliance
 
Enforcement Tracking 02/03/2022 Closed Without Enforcement GILLMAN_M Enforcement
 
Letter 01/14/2022 Satisfied GILLMAN_M Enforcement
 
Enforcement Referral 01/05/2022 Accepted WILSON_ML_1 Enforcement
 
Record Document 12/22/2021 Satisfied WILSON_ML_1 Compliance Assistance
 
Record Document 12/13/2021 Satisfied WILSON_ML_1 Compliance Assistance
 
Site Inspection 10/07/2021 Major Out of Compliance PAYNE_CL_1 0/3 Routine Compliance
 
Letter 10/07/2021 Satisfied WILSON_ML_1 Compliance Assistance
 
Issue Document 10/07/2021 Satisfied WILSON_ML_1 Compliance Assistance
 
Electronic Communication 10/04/2021 Satisfied PAYNE_CL_1 Routine Compliance
 
Letter 10/23/2020 Satisfied WILSON_ML_1 Installation
 
Site Inspection 10/23/2020 In Compliance PAYNE_CL_1 0/1 Installation
 
Issue Document 10/23/2020 Satisfied WILSON_ML_1 Installation
 
Letter 09/02/2020 Satisfied WILSON_ML_1 Closure
 
Site Inspection 09/02/2020 In Compliance PAYNE_CL_1 0/1 Closure
 
Issue Document 09/02/2020 Satisfied WILSON_ML_1 Closure
 
Letter 08/11/2020 Satisfied WILSON_ML_1 Closure
 
Issue Document 08/11/2020 Satisfied WILSON_ML_1 Closure
 
TCAR 08/11/2020 Satisfied PAYNE_CL_1 Closure
 
Document Management 08/11/2020 Satisfied WILSON_ML_1 Closure
 
Issue Document 08/10/2020 Satisfied WILSON_ML_1 Closure
 
Letter 08/10/2020 Satisfied WILSON_ML_1 Closure
 
Document Management 08/10/2020 Satisfied WILSON_ML_1 Closure
 
Letter 09/18/2019 Satisfied WILSON_ML_1 Routine Compliance
 
Site Inspection 09/18/2019 In Compliance PAYNE_CL_1 0/1 Routine Compliance
 
Issue Document 09/18/2019 Satisfied WILSON_ML_1 Routine Compliance
 
Electronic Communication 09/17/2019 Satisfied PAYNE_CL_1 Routine Compliance
 
Site Inspection 02/27/2017 In Compliance PAYNE_CL_1 0/1 Routine Compliance
 
Site Inspection 01/12/2015 In Compliance FOXWORTH_S_1 0/1 Routine Compliance
 
Emergency Preparedness Information 01/12/2015 Satisfied FOXWORTH_S_1 Routine Compliance
 
Site Inspection 10/01/2013 In Compliance FOXWORTH_S_1 0/1 Routine Compliance
 
Emergency Preparedness Information 10/01/2013 Satisfied FOXWORTH_S_1 Routine Compliance
 
Site Inspection 09/14/2011 In Compliance PORTER_AJ_1 0/1 Routine Compliance
 
Emergency Preparedness Information 09/14/2011 Satisfied PORTER_AJ_1 Routine Compliance
 
Incident 11/16/2010 Has not led to Discharge THAYER_JD_1 Incident
 
Site Inspection 11/02/2010 In Compliance THAYER_JD_1 0/1 Non-Compliance
 
Letter 10/01/2010 Satisfied PIERCE_LL_1 Non-Compliance
 
Document Management 09/30/2010 Complete THAYER_JD_1 Incident
 
Site Inspection 09/22/2010 Minor Out of Compliance THAYER_JD_1 0/1 Routine Compliance
 
Emergency Preparedness Information 09/22/2010 Satisfied THAYER_JD_1 Routine Compliance
 
Record Document 03/31/2010 Satisfied THAYER_JD_1 Closure
 
Site Inspection 03/19/2010 In Compliance THAYER_JD_1 0/5 Installation
 
Site Inspection 02/23/2010 In Compliance THAYER_JD_1 0/5 Routine Compliance
 
Site Inspection 01/29/2010 In Compliance TISSINGTON_AB_1 0/5 Closure
 
Letter 11/18/2009 Satisfied PIERCE_LL_1 Non-Compliance
 
Site Inspection 11/06/2009 Minor Out of Compliance THAYER_JD_1 0/5 Routine Compliance
 
Record Document 11/06/2009 Satisfied THAYER_JD_1 Routine Compliance
 
Site Inspection 11/05/2008 In Compliance THAYER_JD_1 0/5 Installation
 
Site Inspection 11/04/2008 In Compliance THAYER_JD_1 0/5 Closure
 
Site Inspection 10/09/2008 In Compliance THAYER_JD_1 0/4 Routine Compliance
 
Meeting 10/02/2008 Satisfied THAYER_JD_1 Routine Compliance
 
Letter 03/27/2008 Satisfied STEVENSON_JS Non-Compliance
 
Site Inspection 03/14/2008 Minor Out of Compliance STEVENSON_JS 0/5 Routine Compliance
 
Record Document 07/25/2007 Satisfied THAYER_JD_1 Non-Compliance
 
Letter 06/25/2007 Satisfied THAYER_JD_1 Non-Compliance
 
Site Inspection 06/11/2007 Minor Out of Compliance THAYER_JD_1 0/5 Routine Compliance
 
Emergency Preparedness Information 02/08/2007 Satisfied THAYER_JD_1 Routine Compliance
 
Emergency Preparedness Information 09/22/2006 Satisfied THAYER_JD_1 Routine Compliance
 
 
 
No Open AOCs Found
 
 
No Open Violations Found
 
 
Discharge Information
 
Discharge
Date
  Clean Up
Status
Score Eligibility Info Site Manager Phone
09/26/1986   ACTIVE 56 EARLY DETECTION INCENTIVE-ELIGIBLE PETTY_J