DEP Logo Florida Department of
Environmental Protection


Bob Martinez Center
2600 Blair Stone Road
Tallahassee, Florida 32399-2400
Storage Tanks &
Contamination
Monitoring Information
 
Cover Page Report
Report Run Date: 05/09/2025        Last Data Refresh: 05/08/2025        Report Generated from DOPPLER
 
District South   Type    Retail Station
 
County Collier   Status    OPEN
 
ID 8518131   Latitude    26° 9' 16.7147
 
Name SOUTHERN PETRO HOLDINGS
8900 DAVIS BLVD
Longitude    81° 41' 14.1764
  NAPLES, FL 34112 LL Method    DPHO
 
Contact Paola Serrano   LL Status    REVIEWED
 
Phone (941) 769-5519   Status Date    04/22/2003
 
Account Owner Information
 
Name SOUTHERN PETRO HOLDINGS LLC
1909 W ATLANTIC AVE
Delray Beach, FL 33444
Effective Date    05/23/2023
 
Contact PAOLA
 
Phone (954) 227-5948
 
Email PAOLA@UNITEDPETROMANAGEMENT.COM
  Placard # / Date    678256 - 06/05/2024
Property Owner Information
 
Name SOUTHERN PETRO HOLDINGS LLC
1909 W ATLANTIC AVE
Delray Beach, FL 33444
Effective Date    05/23/2023
 
Contact PAOLA
 
Phone (954) 227-5948
 
Email PAOLA@UNITEDPETROMANAGEMENT.COM
 
 
 
 
 
 
 
 
 
Tank Tank Size Content Installed Placement Status
5 10000 Unleaded Gas (B) 03/01/2010 UNDERGROUND In Service (U)
 
Constructions   Pipings Monitorings
(C) Steel
(F) Fiberglass clad steel
(I) Double wall
(L) Compartmented
(M) Spill containment bucket
(N) Flow shut-Off
(P) Level gauges/alarms
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(1) Continuous electronic sensing
(3) Electronic monitor pipe sumps
(4) Visual inspect dispenser liners
(F) Monitor dbl wall tank space
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
 
 
Tank Tank Size Content Installed Placement Status
6 10000 Unleaded Gas (B) 03/01/2010 UNDERGROUND In Service (U)
 
Constructions   Pipings Monitorings
(C) Steel
(F) Fiberglass clad steel
(I) Double wall
(N) Flow shut-Off
(O) Tight fill
(P) Level gauges/alarms
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(1) Continuous electronic sensing
(3) Electronic monitor pipe sumps
(4) Visual inspect dispenser liners
(F) Monitor dbl wall tank space
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
 
 
Tank Tank Size Content Installed Placement Status
7 10000 Unleaded Gas (B) 03/01/2010 UNDERGROUND In Service (U)
 
Constructions   Pipings Monitorings
(C) Steel
(F) Fiberglass clad steel
(I) Double wall
(M) Spill containment bucket
(N) Flow shut-Off
(P) Level gauges/alarms
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(1) Continuous electronic sensing
(3) Electronic monitor pipe sumps
(4) Visual inspect dispenser liners
(F) Monitor dbl wall tank space
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
 
 
Tank Tank Size Content Installed Placement Status
1 10000 Vehicular Diesel (D) 01/01/1983 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(E) Fiberglass
(M) Spill containment bucket
(O) Tight fill
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(L) Automatic tank gauging - USTs
 
 
Tank Tank Size Content Installed Placement Status
2 10000 Unleaded Gas (B) 01/01/1983 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(E) Fiberglass
(M) Spill containment bucket
(O) Tight fill
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(L) Automatic tank gauging - USTs
 
 
Tank Tank Size Content Installed Placement Status
3 10000 Unleaded Gas (B) 01/01/1983 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(E) Fiberglass
(M) Spill containment bucket
(O) Tight fill
  (C) Fiberglass
(F) Double wall
(J) Pressurized piping system
(K) Dispenser liners
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(H) Mechanical line leak detector
(K) Monitor dbl wall pipe space
(L) Automatic tank gauging - USTs
 
 
Tank Tank Size Content Installed Placement Status
4 1000 Other Non Regulated (Z) 07/01/1983 UNDERGROUND Removed from Site (B)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(E) Fiberglass
  (C) Fiberglass (8) Manually sampled wells
 
 
Insurance Documents
 
FR Type   Effective Date Expiration Date Company Name
INSURANCE   04/08/2017 04/08/2018 ACE AMERICAN INSURANCE COMPANY
INSURANCE   04/08/2016 04/08/2017 ACE AMERICAN INSURANCE COMPANY
INSURANCE   04/08/2015 04/08/2016 ACE AMERICAN INSURANCE COMPANY
INSURANCE   04/08/2013 04/08/2014 AMERICAN SAFETY
INSURANCE   04/08/2012 04/08/2013 COMMERCE & INDUSTRY
INSURANCE   04/08/2011 04/08/2012 COMMERCE & INDUSTRY
INSURANCE   09/27/2010 09/27/2011 COMMERCE & INDUSTRY
INSURANCE   09/27/2009 09/27/2010 COMMERCE & INDUSTRY
INSURANCE   09/27/2008 09/27/2009 COMMERCE & INDUSTRY
 
 
Legacy Compliance Activity Information
 
Activity
Code
Date
Initiated
Date
Completed
Results Inspector AST/UST
Count
Description
TCI 01/10/2006 01/30/2006 MINOR OUT-OF-COMPLIANCE OWEN_JA 0/3 COMPLIANCE ASSURANCE
 
 Completion Notes VIOLATION # 1103, 1105, 1117. PERFORM HYDROSTATIC ON SPILL BUCKETS. SENSORS & MLLD'S NEED ANNUAL OPERABILITY TEST
 
TCI 02/11/2005 02/17/2005 MINOR OUT-OF-COMPLIANCE KOLANDA 0/3 COMPLIANCE ASSURANCE
 
 Completion Notes #1117: ANNUAL TESTS
 
CWOE 04/13/2004 04/15/2004 KOLANDA 0/3 COMPLIANCE ASSURANCE
 
 Completion Notes VERIFIED SHEAR VALVES ANCHORED & HOSES ARE IN NEW CONDITION ==>CLOSED #144 & PCW REMOVED FROM SPILL CONTAINMENT ==>CLOSED #155
 
TCI 04/13/2004 04/15/2004 IN-COMPLIANCE KOLANDA 0/3 COMPLIANCE ASSURANCE
 
 Completion Notes PIPING: DW FIBERGLASS
 
RRBD 09/09/2003 09/11/2003 KOLANDA 0/3 COMPLIANCE ASSURANCE
 
 Completion Notes TANK TIGHTNESS REQ'D EVERY 3 YRS...REC'D TANK TIGHTNESS RESULTS
 
NCLI 04/16/2003 04/21/2003 HOGAN_S /0 COMPLIANCE ASSURANCE
 
 Completion Notes TCI DATED 4/8/03
 
TCI 04/08/2003 04/09/2003 SIGNIFICANT OUT-OF-COMPLIANCE HOGAN_S 0/3 COMPLIANCE ASSURANCE
 
 Completion Notes RE-ANCHOR SHEAR VALVES. WORN DISPENSER HOSES. REMOVE DEBRIS FROM SPILL BUCKETS. REMOVE DIESEL FROM DISPENSER LINER #9. TANK TIGHTNESS IN CONJUCNTION WITH ATG PAST DUE, DUE 12/2001. DW RIGID FIBERGLASS PIPING (AMERON).
 
TCI 05/08/2002 05/08/2002 IN-COMPLIANCE HOGAN_S /3 COMPLIANCE ASSURANCE
 
 Completion Notes IN COMPLIANCE.
 
RRBD 07/31/2001 07/31/2001 HOGAN_S 0/0 COMPLIANCE ASSURANCE
 
 Completion Notes LLD PASSED ANNUAL TEST
 
CWOE 07/31/2001 07/31/2001 HOGAN_S 0/0 COMPLIANCE ASSURANCE
 
 Completion Notes CLOSE 157/N
 
TCI 05/08/2001 05/08/2001 MINOR OUT-OF-COMPLIANCE HOGAN_S 0/3 COMPLIANCE ASSURANCE
 
 Completion Notes NEED LLD TESTS
 
TCI 09/07/1999 09/07/1999 IN-COMPLIANCE SILLERY_W 0/3 COMPLIANCE ASSURANCE
 
 
 
Compliance Activity Information
 
Activity
Code
Date
Completed
Results Inspector AST/UST
Count
Description
Enforcement Referral 11/20/2024 Accepted BATES_TD_1 Enforcement
 
Site Inspection 09/19/2023 Major Out of Compliance STANDIFORD_JA 0/3 Routine Compliance
 
Electronic Communication 12/10/2021 Satisfied HERNANDEZ_N_5 Routine Compliance
 
Site Inspection 12/10/2021 Major Out of Compliance HERNANDEZ_N_5 0/3 Routine Compliance
 
Letter 12/10/2021 Satisfied HERNANDEZ_N_5 Compliance Assistance
 
Electronic Communication 10/27/2020 Satisfied HERNANDEZ_N_5 Compliance Assistance
 
Meeting 10/27/2020 Satisfied HERNANDEZ_N_5 Compliance Assistance
 
Site Inspection 12/18/2019 Major Out of Compliance BATES_TD_1 0/3 Routine Compliance
 
Electronic Communication 12/18/2019 Satisfied BATES_TD_1 Routine Compliance
 
Letter 12/18/2019 Satisfied BATES_TD_1 Compliance Assistance
 
Letter 09/06/2019 Satisfied HERNANDEZ_N Compliance Assistance
 
Enforcement Tracking 08/08/2019 Closed Without Enforcement HERNANDEZ_N Enforcement
 
Enforcement Referral 01/24/2018 Accepted STANDIFORD_JA_2 Enforcement
 
Enforcement Referral 01/22/2018 Rejected STANDIFORD_JA_2 Enforcement
 
Record Document 01/16/2018 Satisfied STANDIFORD_JA_2 Compliance Assistance
 
Letter 08/29/2017 Satisfied STANDIFORD_JA_2 Compliance Assistance
 
Site Inspection 08/25/2017 Major Out of Compliance STANDIFORD_JA_2 0/3 Routine Compliance
 
Site Inspection 05/31/2016 In Compliance STANDIFORD_JA_2 0/3 Installation
 
Letter 10/22/2015 Satisfied STANDIFORD_JA_2 Non-Compliance
 
Site Inspection 10/21/2015 Major Out of Compliance STANDIFORD_JA_2 0/3 Routine Compliance
 
Site Inspection 08/27/2014 Major Out of Compliance SNYDERBURN_PJ_2 0/3 Non-Compliance
 
Letter 08/27/2014 Satisfied SNYDERBURN_PJ_2 Non-Compliance
 
Record Document 02/18/2014 Satisfied SNYDERBURN_PJ_2 Non-Compliance
 
Letter 02/12/2014 Satisfied SNYDERBURN_PJ_2 Non-Compliance
 
Site Inspection 02/12/2014 Minor Out of Compliance SNYDERBURN_PJ_2 0/3 Routine Compliance
 
Emergency Preparedness Information 09/23/2013 Satisfied SNYDERBURN_PJ_2 Routine Compliance
 
Discharge Reporting 01/04/2013 Satisfied SNYDERBURN_PJ_2 Discharge
 
Site Inspection 01/04/2013 In Compliance SNYDERBURN_PJ_2 0/3 Discharge
 
Document Management 01/04/2013 Complete SNYDERBURN_PJ_2 Discharge
 
Emergency Preparedness Information 08/26/2012 Satisfied SNYDERBURN_PJ_2 Routine Compliance
 
Site Inspection 04/13/2012 In Compliance SNYDERBURN_PJ_2 0/3 Non-Compliance
 
Letter 02/02/2012 Satisfied SNYDERBURN_PJ_2 Non-Compliance
 
Site Inspection 02/02/2012 Minor Out of Compliance SNYDERBURN_PJ_2 0/3 Routine Compliance
 
Incident 02/07/2011 Has not led to Discharge SNYDERBURN_PJ_2 Incident
 
Emergency Preparedness Information 01/24/2011 Satisfied SNYDERBURN_PJ_2 Routine Compliance
 
Site Inspection 01/24/2011 Minor Out of Compliance SNYDERBURN_PJ_2 0/3 Routine Compliance
 
Letter 01/24/2011 Satisfied SNYDERBURN_PJ_2 Non-Compliance
 
Document Management 01/14/2011 Complete SNYDERBURN_PJ_2 Incident
 
Incident 07/09/2010 Has not led to Discharge SNYDERBURN_PJ_2 Incident
 
Document Management 04/12/2010 Complete SNYDERBURN_PJ_2 Incident
 
TCAR 03/29/2010 Satisfied SNYDERBURN_PJ_2 Closure
 
Letter 03/29/2010 Satisfied SNYDERBURN_PJ_2 Closure
 
Site Inspection 03/29/2010 In Compliance SNYDERBURN_PJ_2 0/3 Closure
 
Emergency Preparedness Information 03/24/2010 Satisfied SNYDERBURN_PJ_2 Installation
 
Site Inspection 03/24/2010 In Compliance SNYDERBURN_PJ_2 0/3 Installation
 
Record Document 03/13/2009 Satisfied NOVAK_KM_1 Non-Compliance
 
Site Inspection 01/16/2009 Minor Out of Compliance NOVAK_KM_1 0/4 Routine Compliance
 
Letter 01/16/2009 Satisfied NOVAK_KM_1 Non-Compliance
 
Emergency Preparedness Information 01/16/2009 Satisfied NOVAK_KM_1 Routine Compliance
 
Record Document 02/04/2008 Satisfied POTTS_CR Non-Compliance
 
Letter 12/26/2007 Satisfied POTTS_CR Non-Compliance
 
Site Inspection 10/19/2007 Minor Out of Compliance POTTS_CR 0/4 Routine Compliance
 
Emergency Preparedness Information 10/19/2007 Satisfied POTTS_CR Routine Compliance
 
Letter 10/19/2007 Satisfied POTTS_CR Non-Compliance
 
Record Document 04/16/2007 Satisfied POTTS_CR Non-Compliance
 
Letter 03/27/2007 Satisfied SNYDERBURN_PJ_2 Non-Compliance
 
Site Inspection 03/20/2007 Major Out of Compliance POTTS_CR 0/3 Routine Compliance
 
Emergency Preparedness Information 02/05/2007 Satisfied POTTS_CR Routine Compliance
 
Emergency Preparedness Information 09/26/2006 Satisfied POTTS_CR Routine Compliance
 
 
 
No Open AOCs Found
 
 
Open Violations
 
Insp Date Vio # Significance Violation Text Corrective Action
09/18/2023 6072 Minor 2.7 Integrity testing of secondary containment systems and interstitial spaces not performed per schedule. Please schedule 3 year integrity testing of UDC's and STP sumps as required by rule. Once completed, please submit the completed test record.
 
09/13/2023 6006 Minor 2.5 Placard not displayed (or available upon request). Please post the current placard in a visible location as required by rule. The current registration fees have been paid.
 
09/12/2023 6063 SNC-B 4.1 Not repaired or isolated component or piping which has not caused a discharge or release. Conduct an integrity test of UDC 5/6 as soon as possible. If the integrity test fails an Incident Notification Form must be submitted. Please then continue with an investigation to determine if surrounding soil around UDC 5/6 has been impacted. If it is determined that a discharge occurred, then sampling will need to occur and an associated assessment report will need to be submitted. If the integrity test passes, sampling will not be required. Please ensure the associated boot is repaired/replaced. Please notify of associated TXI/TIN activity 30 days in advance,10 days in advance, and then 48 hours in advance.
 
12/10/2021 6053 Minor 4.7 Primary overfill protection not provided, registered, or tested as required. Provide system test from 2020 to the current one, or perform system test (OPV-flapper) and send copy by email to the County inspector.
 
12/10/2021 6062 Minor 2.5 Release detection devices not tested annually. Provide system test from 2020 to the current one or perform system test (line leak detector, spill bucket gauges, and Veeder Root and sensors) and send copy by email to the County inspector.
 
12/10/2021 6056 SNC-B 2.4 Release detection not tested or visually inspected once a month or problems found during the visual inspections not recorded. At least once a month, but not exceeding 35 days, every component of a storage tank system that contains, transfers, or stores, or is designed to contain, transfer, or store regulated substances that can be inspected visually shall be visually inspected and documented as to its condition pursuant to Rule 62-761.710, F.A.C. For three consecutive months (December, January, and February) perform the MVI and send copy to the County inspector by email.
 
12/10/2021 6001 Minor 2.1 No reasonable access provided. The facility owner or operator shall provide an authorized facility representative to unlock and open any covers, manways, and release detection equipment associated with the storage tank system or system component at time of the inspection. Violation shall be resolve with the issuance of the CAO Letter.
 
12/10/2021 6074 Minor 2.8 Improper maintenance of records. Records requiring to be maintained for 3 years or for the life of the system not kept by facility. Records not provided within 5 business days. Records shall be kept for three years. Violation shall be resolved with the issuance of the CAO Letter.
 
12/16/2019 4068 Minor 4.3 Storage tank system has a not repaired component which has or could cause a release or discharge. Submit an Incident Notification Form. Remove liquids. Investigate as an Incident. Provide the county with a passing integrity test and an explanation of repairs. If the secondary bucket was affected, sampling may be required. Replace the gauge or alternatively, document visual interstitial checks monthly.
 
12/16/2019 4049 Minor 4.24 Dispensers not installed and maintained according to reference guidelines. Replace damaged or aged hoses or whips #2, #4, and #6. Replace missing shear valve anchor bolts in #4 and #8
 
12/13/2019 4014 SNC-B 2.9 Failure to maintain and demonstrate financial responsibility. This violation may lead to Placard Revocation and Delivery Prohibition. Send proof of FR to the county. The proof should include FDEP Form Part P, the Certification of Financial Responsibility
 
 
 
Discharge Information
 
Discharge
Date
  Clean Up
Status
Score Eligibility Info Site Manager Phone
12/27/1988   COMPLETED 26 EARLY DETECTION INCENTIVE-ELIGIBLE