Florida Department of Environmental Protection Bob Martinez Center 2600 Blair Stone Road Tallahassee, Florida 32399-2400 |
Storage Tanks & Contamination Monitoring Information |
||||||||||
Cover Page Report | |||||||||||
Report Run Date: 02/02/2025 Last Data Refresh: 02/01/2025 Report Generated from DOPPLER | |||||||||||
District | Southwest | Type | Retail Station | ||||||||
County | Pinellas | Status | OPEN | ||||||||
ID | 8626278 | Latitude | 27° 49' 17.9227 | ||||||||
Name |
CITGO-CUMBERLAND 5401 SEMINOLE BLVD |
Longitude | 82° 47' 12.0803 | ||||||||
SEMINOLE, FL 33772-7318 | LL Method | DPHO | |||||||||
Contact | RAHIM MARDHANI | LL Status | REVIEWED | ||||||||
Phone | (727) 201-8930 | Status Date | 10/17/2003 | ||||||||
Account Owner Information | |||||||||||
Name | JUBILEE OIL LLC 5401 SEMINOLE BLVD SEMINOLE, FL 33772 |
Effective Date | 06/28/2019 | ||||||||
Contact | RAHLIM MARDHANI | ||||||||||
Phone | (678) 687-2712 | ||||||||||
JUBILEEOIL1@GMAIL.COM | |||||||||||
Placard # / Date | 703184 - 10/28/2024 | ||||||||||
Property Owner Information | |||||||||||
Name | W G DAVIS HOLDINGS LLC 10724 CORY LAKES DR TAMPA, FL 33647 |
Effective Date | 08/26/2019 | ||||||||
Contact | |||||||||||
Phone | (970) 903-5957 | ||||||||||
WGDAVISMD@GMAIL.COM | |||||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
5 | 12000 | Unleaded Gas (B) | 02/01/2005 | UNDERGROUND | In Service (U) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (E) Fiberglass (I) Double wall (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (K) Monitor dbl wall pipe space |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
6 | 12000 | Unleaded Gas (B) | 02/01/2005 | UNDERGROUND | In Service (U) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (E) Fiberglass (I) Double wall (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (K) Monitor dbl wall pipe space |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
7 | 8000 | Unleaded Gas (B) | 02/01/2005 | UNDERGROUND | In Service (U) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (E) Fiberglass (I) Double wall (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (K) Monitor dbl wall pipe space |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
10 | 8000 | Unleaded Gas (B) | 02/01/2005 | UNDERGROUND | Deleted - Data Error (D) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (E) Fiberglass (I) Double wall (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (K) Dispenser liners |
(F) Monitor dbl wall tank space (H) Mechanical line leak detector (L) Automatic tank gauging - USTs (S) Statistical Inventory Reconcile |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
1R1 | 8000 | Unleaded Gas (B) | 10/01/1986 | UNDERGROUND | Removed from Site (B) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (F) Fiberglass clad steel (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(H) Mechanical line leak detector (K) Monitor dbl wall pipe space (S) Statistical Inventory Reconcile |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
2R1 | 8000 | Unleaded Gas (B) | 10/01/1986 | UNDERGROUND | Removed from Site (B) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (F) Fiberglass clad steel (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(H) Mechanical line leak detector (K) Monitor dbl wall pipe space (S) Statistical Inventory Reconcile |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
3R1 | 8000 | Unleaded Gas (B) | 10/01/1986 | UNDERGROUND | Removed from Site (B) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (F) Fiberglass clad steel (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(H) Mechanical line leak detector (K) Monitor dbl wall pipe space (S) Statistical Inventory Reconcile |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
8 | 12000 | Unleaded Gas (B) | 02/01/2005 | UNDERGROUND | Deleted - Data Error (D) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (E) Fiberglass (I) Double wall (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system |
(F) Monitor dbl wall tank space (H) Mechanical line leak detector (L) Automatic tank gauging - USTs (S) Statistical Inventory Reconcile |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
9 | 12000 | Unleaded Gas (B) | 02/01/2005 | UNDERGROUND | Deleted - Data Error (D) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (E) Fiberglass (I) Double wall (M) Spill containment bucket (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system |
(F) Monitor dbl wall tank space (H) Mechanical line leak detector (L) Automatic tank gauging - USTs (S) Statistical Inventory Reconcile |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
1 | 10000 | Leaded Gas (A) | UNDERGROUND | Removed from Site (B) | |||||||
Constructions | Pipings | Monitorings | |||||||||
(D) Unknown | (Y) Unknown | (Y) Unknown | |||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
2 | 4000 | Leaded Gas (A) | UNDERGROUND | Removed from Site (B) | |||||||
Constructions | Pipings | Monitorings | |||||||||
(D) Unknown | (Y) Unknown | (Y) Unknown | |||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
3 | 4000 | Leaded Gas (A) | UNDERGROUND | Removed from Site (B) | |||||||
Constructions | Pipings | Monitorings | |||||||||
(D) Unknown | (Y) Unknown | (Y) Unknown | |||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
4 | 4000 | Leaded Gas (A) | UNDERGROUND | Removed from Site (B) | |||||||
Constructions | Pipings | Monitorings | |||||||||
(D) Unknown | (Y) Unknown | (Y) Unknown | |||||||||
Insurance Documents | |||||||||||
FR Type | Effective Date | Expiration Date | Company Name | ||||||||
INSURANCE | LIBERTY SURPLUS INSURANCE CORP | ||||||||||
INSURANCE | 10/19/2023 | 10/19/2024 | CRUM & FORSTER SPECIALTY INSURANCE COMPANY | ||||||||
INSURANCE | 10/19/2022 | 10/19/2023 | CRUM & FORSTER SPECIALTY INSURANCE COMPANY | ||||||||
INSURANCE | 10/19/2021 | 10/19/2022 | CRUM & FORSTER SPECIALTY INS. CO. | ||||||||
INSURANCE | 10/19/2020 | 10/19/2021 | CRUM & FORSTER SPECIALTY INS. CO. | ||||||||
INSURANCE | 10/19/2019 | 10/19/2020 | CRUM & FORSTER SPECIALTY INS. CO. | ||||||||
INSURANCE | 10/19/2018 | 10/19/2019 | CRUM & FORSTER SPECIALTY INS. CO. | ||||||||
INSURANCE | 12/20/2017 | 12/20/2018 | CRUM & FORSTER SPECIALTY INS. CO. | ||||||||
INSURANCE | 12/31/2016 | 12/31/2017 | NAUTILUS INSURANCE COMPANY | ||||||||
INSURANCE | 12/31/2015 | 12/31/2016 | LIBERTY SURPLUS INSURANCE CORP | ||||||||
INSURANCE | 12/31/2014 | 12/31/2015 | LIBERTY SURPLUS INSURANCE CORP | ||||||||
INSURANCE | 09/11/2011 | 08/31/2014 | ACE | ||||||||
SELF-INSURANCE - LETTER FROM CHIEF FINANCIAL OFFICER | 01/17/2011 | 08/01/2011 | |||||||||
SELF-INSURANCE - LETTER FROM CHIEF FINANCIAL OFFICER | 01/16/2009 | 01/15/2010 | |||||||||
INSURANCE | 06/26/2006 | 06/26/2011 | AMERICAN INTERNATIONAL SPECIALTY LINES | ||||||||
SELF-INSURANCE - LETTER FROM CHIEF FINANCIAL OFFICER | 06/26/2006 | 06/26/2011 | |||||||||
Legacy Compliance Activity Information | |||||||||||
Activity Code |
Date Initiated |
Date Completed |
Results | Inspector | AST/UST Count |
Description | |||||
TCI | 04/25/2006 | 04/26/2006 | IN-COMPLIANCE | FRAZIER | 0/3 | COMPLIANCE ASSURANCE | |||||
LTR | 04/25/2006 | 04/26/2006 | FRAZIER | 0/0 | COMPLIANCE ASSURANCE | ||||||
LTR | 08/28/2005 | 08/28/2005 | ROGGELIN | 0/0 | DISCHARGE PROJECT | ||||||
Completion Notes RCVD TANK TIGHTNESS TEST TO RESOLVE INF | |||||||||||
NCLI | 08/09/2005 | 08/11/2005 | ROGGELIN | 0/0 | DISCHARGE PROJECT | ||||||
Completion Notes REQUESTED TEST RESULTS | |||||||||||
NCLI | 08/08/2005 | 08/08/2005 | SOWERS | 0/0 | COMPLIANCE ASSURANCE | ||||||
Completion Notes SECOND LETTER SENT TO ATTEMPT TO RESOLVE OUTSTANDING CLOSURE REPORT ISSUES / ORIGINAL COMMENT LETTER SENT 5/4/05 | |||||||||||
NCLI | 05/04/2005 | 08/08/2005 | SOWERS | 0/0 | COMPLIANCE ASSURANCE | ||||||
Completion Notes COMMENT LETTER ISSUED FOR SUBMITTED CLOSURE REPORT | |||||||||||
RRBD | 04/26/2005 | 08/08/2005 | SOWERS | 0/0 | COMPLIANCE ASSURANCE | ||||||
Completion Notes SUBMITTAL OF CLOSURE REPORT | |||||||||||
LTR | 03/15/2005 | 03/22/2005 | FRAZIER | 0/0 | COMPLIANCE ASSURANCE | ||||||
TIN | 03/15/2005 | 03/22/2005 | IN-COMPLIANCE | FRAZIER | 0/3 | COMPLIANCE ASSURANCE | |||||
TXI | 02/25/2005 | 02/28/2005 | IN-COMPLIANCE | FRAZIER | 0/3 | COMPLIANCE ASSURANCE | |||||
Completion Notes (3) 8000-GAL SW FRP-CLAD STEEL TANKS REMOVED | |||||||||||
LTR | 05/11/2004 | 05/25/2004 | PINK | 0/0 | COMPLIANCE ASSURANCE | ||||||
TCI | 05/11/2004 | 05/25/2004 | IN-COMPLIANCE | PINK | 0/3 | COMPLIANCE ASSURANCE | |||||
Completion Notes AMERON DW FRP PIPE | |||||||||||
NCLI | 10/15/2002 | 10/29/2002 | SOWERS | 0/0 | COMPLIANCE ASSURANCE | ||||||
LTR | 10/11/2002 | 10/29/2002 | STRAUSS | 0/0 | COMPLIANCE ASSURANCE | ||||||
TCI | 10/08/2002 | 10/29/2002 | IN-COMPLIANCE | STRAUSS | 0/3 | COMPLIANCE ASSURANCE | |||||
RRBD | 11/06/2001 | 12/19/2001 | COMPLIANCE ASSURANCE | ||||||||
TCI | 11/05/2001 | 11/29/2001 | SIGNIFICANT OUT-OF-COMPLIANCE | TAM | 0/3 | COMPLIANCE ASSURANCE | |||||
TCI | 11/29/2000 | 11/30/2000 | IN-COMPLIANCE | CASTOR | 0/3 | COMPLIANCE ASSURANCE | |||||
TCI | 03/16/2000 | 03/20/2000 | IN-COMPLIANCE | CASTOR | 0/3 | COMPLIANCE ASSURANCE | |||||
TCI | 05/06/1999 | 06/13/1999 | IN-COMPLIANCE | DUGGAN | 0/0 | COMPLIANCE ASSURANCE | |||||
Compliance Activity Information | |||||||||||
Activity Code |
Date Completed |
Results | Inspector | AST/UST Count |
Description | ||||||
Document Management | 01/22/2025 | Satisfied | KELLEY_T | Enforcement | |||||||
Enforcement Referral | 10/15/2024 | Accepted | PUHR_NM_1 | Enforcement | |||||||
Record Document | 08/09/2024 | Satisfied | PUHR_NM_1 | Compliance Assistance | |||||||
Site Inspection | 05/07/2024 | Minor Out of Compliance | PUHR_NM_1 | 0/3 | Routine Compliance | ||||||
Letter | 05/07/2024 | Satisfied | PUHR_NM_1 | Compliance Assistance | |||||||
Letter | 04/18/2022 | Satisfied | COLSON_NJ_1 | Routine Compliance | |||||||
Site Inspection | 04/18/2022 | In Compliance | COLSON_NJ_1 | 0/3 | Routine Compliance | ||||||
Electronic Communication | 03/01/2022 | Satisfied | COLSON_NJ_1 | Routine Compliance | |||||||
Letter | 04/24/2020 | Satisfied | COLSON_NJ_1 | Compliance Assistance | |||||||
Site Inspection | 04/24/2020 | Minor Out of Compliance | COLSON_NJ_1 | 0/3 | Routine Compliance | ||||||
Electronic Communication | 02/21/2020 | Satisfied | COLSON_NJ_1 | Routine Compliance | |||||||
Record Document | 08/23/2017 | Satisfied | COLSON_NJ_1 | Compliance Assistance | |||||||
Letter | 08/23/2017 | Satisfied | COLSON_NJ_1 | Compliance Assistance | |||||||
Letter | 06/08/2017 | Satisfied | COLSON_NJ_1 | Non-Compliance | |||||||
Site Inspection | 06/08/2017 | Minor Out of Compliance | COLSON_NJ_1 | 0/3 | Non-Compliance | ||||||
Site Inspection | 05/26/2017 | Minor Out of Compliance | COLSON_NJ_1 | 0/3 | Routine Compliance | ||||||
Letter | 05/26/2017 | Satisfied | COLSON_NJ_1 | Non-Compliance | |||||||
Electronic Communication | 05/01/2017 | Satisfied | COLSON_NJ_1 | Routine Compliance | |||||||
Letter | 07/02/2015 | Satisfied | COLSON_NJ_1 | Non-Compliance | |||||||
Site Inspection | 07/02/2015 | Minor Out of Compliance | COLSON_NJ_1 | 0/2 | Non-Compliance | ||||||
Site Inspection | 04/23/2015 | Major Out of Compliance | COLSON_NJ_1 | 0/3 | Routine Compliance | ||||||
Letter | 04/23/2015 | Satisfied | COLSON_NJ_1 | Non-Compliance | |||||||
Site Inspection | 02/18/2013 | In Compliance | STRAUSS_RH_1 | 0/3 | Non-Compliance | ||||||
Letter | 01/22/2013 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||||||
Site Inspection | 01/22/2013 | Minor Out of Compliance | STRAUSS_RH_1 | 0/3 | Routine Compliance | ||||||
Site Inspection | 07/22/2011 | In Compliance | STRAUSS_RH_1 | 0/3 | Non-Compliance | ||||||
Site Inspection | 07/18/2011 | Minor Out of Compliance | SOWERS_JA_1 | 0/3 | Routine Compliance | ||||||
Letter | 07/18/2011 | Satisfied | SOWERS_JA_1 | Non-Compliance | |||||||
Emergency Preparedness Information | 07/15/2011 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||||||
Emergency Preparedness Information | 07/15/2011 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||||||
Site Inspection | 04/12/2011 | In Compliance | STRAUSS_RH_1 | 0/3 | Non-Compliance | ||||||
Letter | 12/15/2010 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||||||
Site Inspection | 12/15/2010 | Minor Out of Compliance | STRAUSS_RH_1 | 0/3 | Routine Compliance | ||||||
Record Document | 12/29/2009 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Site Inspection | 12/16/2009 | Minor Out of Compliance | LONGEN_JL_1 | 0/3 | Routine Compliance | ||||||
Letter | 12/16/2009 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Site Inspection | 10/14/2008 | In Compliance | BARNETT_JX | 0/3 | Non-Compliance | ||||||
Letter | 09/25/2008 | Satisfied | BARNETT_JX | Non-Compliance | |||||||
Emergency Preparedness Information | 09/25/2008 | Satisfied | BARNETT_JX | Routine Compliance | |||||||
Site Inspection | 09/25/2008 | Minor Out of Compliance | BARNETT_JX | 0/3 | Routine Compliance | ||||||
Site Inspection | 01/02/2008 | In Compliance | LONGEN_JL_1 | 0/2 | Non-Compliance | ||||||
Record Document | 10/18/2007 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Site Inspection | 09/26/2007 | Minor Out of Compliance | LONGEN_JL_1 | 0/3 | Routine Compliance | ||||||
Emergency Preparedness Information | 09/26/2007 | Satisfied | LONGEN_JL_1 | Routine Compliance | |||||||
Letter | 09/26/2007 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Emergency Preparedness Information | 02/05/2007 | Satisfied | LONGEN_JL_1 | Routine Compliance | |||||||
Site Inspection | 01/30/2007 | In Compliance | BARNETT_JX | 0/3 | Routine Compliance | ||||||
Emergency Preparedness Information | 09/25/2006 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||||||
No Open AOCs Found | |||||||||||
No Open Violations Found | |||||||||||
Discharge Information | |||||||||||
Discharge Date |
Clean Up Status |
Score | Eligibility Info | Site Manager | Phone | ||||||
06/12/1998 | ACTIVE | 11 | PETROLEUM LIABILITY AND RESTORATION INSURANCE PROGRAM-ELIGIBLE | ||||||||
08/27/1992 | COMPLETED | 10 | |||||||||