Florida Department of Environmental Protection Bob Martinez Center 2600 Blair Stone Road Tallahassee, Florida 32399-2400 |
Storage Tanks & Contamination Monitoring Information |
|||||||||
Cover Page Report | |||||||||||
Report Run Date: 05/17/2025 Last Data Refresh: 05/16/2025 Report Generated from DOPPLER | |||||||||||
District | Southwest | Type | Retail Station | ||||||||
County | Pinellas | Status | OPEN | ||||||||
ID | 8840982 | Latitude | 27° 59' 2.1983 | ||||||||
Name |
COACHMAN CAR WASH 23331 US 19 N |
Longitude | 82° 43' 45.0024 | ||||||||
CLEARWATER, FL 33765-1532 | LL Method | DPHO | |||||||||
Contact | FISHER & SONS | LL Status | REVIEWED | ||||||||
Phone | (727) 797-6809 | Status Date | 11/05/2003 | ||||||||
Account Owner Information | |||||||||||
Name | H GREGG FISHER & SON INC 23331 US HWY 19 N CLEARWATER, FL 33765 |
Effective Date | 05/20/1994 | ||||||||
Contact | GREGG FISHER | ||||||||||
Phone | (727) 504-6586 | ||||||||||
CCFISH2177@GMAIL.COM | |||||||||||
Placard # / Date | 684497 - 06/06/2024 | ||||||||||
Property Owner Information | |||||||||||
Name | H GREGG FISHER & SON INC 23331 US HWY 19 N CLEARWATER, FL 33765 |
Effective Date | 04/27/2023 | ||||||||
Contact | GREGG FISHER | ||||||||||
Phone | (727) 504-6586 | ||||||||||
CCFISH2177@GMAIL.COM | |||||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
1 | 10000 | Unleaded Gas (B) | 07/01/1979 | UNDERGROUND | Removed from Site (B) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(C) Steel (M) Spill containment bucket (O) Tight fill |
(B) Steel/galvanized metal (J) Pressurized piping system |
(8) Manually sampled wells | |||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
2 | 10000 | Unleaded Gas (B) | 07/01/1979 | UNDERGROUND | Removed from Site (B) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(C) Steel (M) Spill containment bucket (O) Tight fill |
(B) Steel/galvanized metal (J) Pressurized piping system |
(8) Manually sampled wells | |||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
3 | 12000 | Unleaded Gas (B) | 01/01/1996 | UNDERGROUND | Out of Service (T) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(A) Ball check valve (E) Fiberglass (I) Double wall (L) Compartmented (M) Spill containment bucket (N) Flow shut-Off (O) Tight fill |
(J) Pressurized piping system (K) Dispenser liners (M) Double wall - pipe jacket (N) Approved synthetic material |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (K) Monitor dbl wall pipe space |
|||||||||
Insurance Documents | |||||||||||
FR Type | Effective Date | Expiration Date | Company Name | ||||||||
INSURANCE | 11/16/2022 | 11/16/2023 | COMMERCE AND INDUSTRY INSURANCE COMPANY | ||||||||
INSURANCE | 11/16/2020 | 11/16/2021 | COMMERCE & INDUSTRY INSURANCE CO | ||||||||
INSURANCE | 11/16/2019 | 11/16/2020 | COMMERCE & INDUSTRY INSURANCE CO | ||||||||
INSURANCE | 11/06/2018 | 11/06/2019 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/06/2017 | 11/06/2018 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/16/2016 | 11/16/2017 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/16/2015 | 11/16/2016 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/16/2013 | 11/16/2014 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/16/2012 | 11/16/2013 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/16/2011 | 11/16/2012 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/16/2010 | 11/16/2011 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/16/2009 | 11/16/2010 | COMMERCE & INDUSTRY | ||||||||
INSURANCE | 11/16/2008 | 11/16/2009 | COMMERCE & INDUSTRY | ||||||||
Legacy Compliance Activity Information | |||||||||||
Activity Code |
Date Initiated |
Date Completed |
Results | Inspector | AST/UST Count |
Description | |||||
TCI | 04/14/2006 | 04/14/2006 | MINOR OUT-OF-COMPLIANCE | BARNETT | 0/1 | COMPLIANCE ASSURANCE | |||||
NCLI | 04/14/2006 | 04/14/2006 | BARNETT | 0/0 | COMPLIANCE ASSURANCE | ||||||
LTR | 04/11/2005 | 04/11/2005 | FRAZIER | 0/0 | COMPLIANCE ASSURANCE | ||||||
TCR | 04/08/2005 | 04/11/2005 | IN-COMPLIANCE | FRAZIER | 0/1 | COMPLIANCE ASSURANCE | |||||
LTR | 03/28/2005 | 03/30/2005 | FRAZIER | 0/0 | COMPLIANCE ASSURANCE | ||||||
TIN | 03/25/2005 | 03/30/2005 | IN-COMPLIANCE | FRAZIER | 0/1 | COMPLIANCE ASSURANCE | |||||
Completion Notes INSTALL OF ENVIRON GEO-FLEX D PIPING | |||||||||||
LTR | 03/22/2005 | 03/23/2005 | FRAZIER | 0/0 | COMPLIANCE ASSURANCE | ||||||
TXI | 03/16/2005 | 03/23/2005 | IN-COMPLIANCE | FRAZIER | 0/1 | COMPLIANCE ASSURANCE | |||||
Completion Notes REMOVAL OF TCI WHITE SW FLEX PIPING FROM SECONDARY CHASE | |||||||||||
TCI | 09/14/2004 | 09/23/2004 | MINOR OUT-OF-COMPLIANCE | PINK | 0/1 | COMPLIANCE ASSURANCE | |||||
NCLI | 09/14/2004 | 09/23/2004 | PINK | 0/0 | COMPLIANCE ASSURANCE | ||||||
LTR | 11/18/2003 | 11/24/2003 | STRAUSS | 0/0 | COMPLIANCE ASSURANCE | ||||||
TCR | 11/18/2003 | 11/24/2003 | IN-COMPLIANCE | STRAUSS | 0/1 | COMPLIANCE ASSURANCE | |||||
NCLI | 11/03/2003 | 11/04/2003 | PINK | 0/0 | COMPLIANCE ASSURANCE | ||||||
TCI | 10/29/2003 | 11/04/2003 | MINOR OUT-OF-COMPLIANCE | HALSCOTT | 0/1 | COMPLIANCE ASSURANCE | |||||
Completion Notes TC WHITE FLEX PIPING IN SECONDARY CHASE | |||||||||||
RRBD | 10/02/2002 | 10/29/2002 | COMPLIANCE ASSURANCE | ||||||||
NCLI | 09/11/2002 | 09/16/2002 | TAM | 0/0 | COMPLIANCE ASSURANCE | ||||||
TCI | 09/10/2002 | 09/16/2002 | MINOR OUT-OF-COMPLIANCE | TAM | 0/1 | COMPLIANCE ASSURANCE | |||||
TCI | 08/20/2001 | 08/24/2001 | MINOR OUT-OF-COMPLIANCE | HALSCOTT | 0/1 | COMPLIANCE ASSURANCE | |||||
TCR | 12/11/2000 | 12/27/2000 | IN-COMPLIANCE | STRAUSS | 0/1 | COMPLIANCE ASSURANCE | |||||
TCI | 09/21/2000 | 09/22/2000 | MINOR OUT-OF-COMPLIANCE | HALSCOTT | 0/1 | COMPLIANCE ASSURANCE | |||||
RRBD | 03/20/2000 | 03/20/2000 | HALSCOTT | 0/0 | COMPLIANCE ASSURANCE | ||||||
RRBD | 03/15/2000 | 03/20/2000 | HALSCOTT | 0/0 | COMPLIANCE ASSURANCE | ||||||
TCI | 03/09/2000 | 03/20/2000 | SIGNIFICANT OUT-OF-COMPLIANCE | HALSCOTT | 0/1 | COMPLIANCE ASSURANCE | |||||
Compliance Activity Information | |||||||||||
Activity Code |
Date Completed |
Results | Inspector | AST/UST Count |
Description | ||||||
Enforcement Tracking | 02/14/2025 | Closed Without Enforcement | WIMBERLY_E | Enforcement | |||||||
Document Management | 02/14/2025 | Satisfied | WIMBERLY_E | Enforcement | |||||||
Enforcement Referral | 02/04/2025 | Accepted | MUSLIC_A_1 | Enforcement | |||||||
Letter | 01/13/2025 | Satisfied | MUSLIC_A_1 | Compliance Assistance | |||||||
Site Inspection | 01/13/2025 | Major Out of Compliance | MUSLIC_A_1 | 0/1 | Routine Compliance | ||||||
Electronic Communication | 12/09/2024 | Satisfied | MUSLIC_A_1 | Routine Compliance | |||||||
Electronic Communication | 05/15/2023 | Satisfied | SHOCK_E_1 | Compliance Assistance | |||||||
Letter | 04/18/2023 | Satisfied | SHOCK_E_1 | Compliance Assistance | |||||||
Site Inspection | 04/15/2023 | Minor Out of Compliance | SHOCK_E_1 | 0/1 | Routine Compliance | ||||||
Electronic Communication | 03/27/2023 | Satisfied | SHOCK_E_1 | Routine Compliance | |||||||
Site Inspection | 04/05/2021 | Minor Out of Compliance | STRAUSS_RH_1 | 0/1 | Routine Compliance | ||||||
Letter | 04/05/2021 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||||||
Electronic Communication | 03/25/2021 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||||||
Letter | 05/12/2020 | Satisfied | PACELKO_A | Enforcement | |||||||
Electronic Communication | 03/18/2020 | Satisfied | PACELKO_A | Enforcement | |||||||
Enforcement Referral | 10/30/2019 | Accepted | STRAUSS_RH_1 | Enforcement | |||||||
Electronic Communication | 10/10/2019 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||||||
Electronic Communication | 10/10/2019 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||||||
Electronic Communication | 10/10/2019 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||||||
Phone Conversation | 10/10/2019 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||||||
Site Inspection | 01/18/2019 | Minor Out of Compliance | STRAUSS_RH_1 | 0/1 | Routine Compliance | ||||||
Letter | 01/18/2019 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||||||
Electronic Communication | 01/07/2019 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||||||
Site Inspection | 08/17/2017 | In Compliance | STRAUSS_RH_1 | 0/1 | Compliance Assistance | ||||||
Record Document | 08/17/2017 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||||||
Issue Document | 08/17/2017 | Satisfied | STRAUSS_RH_1 | Compliance Assistance | |||||||
Letter | 08/25/2016 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||||||
Site Inspection | 08/25/2016 | Minor Out of Compliance | STRAUSS_RH_1 | 0/1 | Routine Compliance | ||||||
Electronic Communication | 08/05/2016 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||||||
Site Inspection | 04/15/2014 | Minor Out of Compliance | COLSON_NJ_1 | 0/1 | Routine Compliance | ||||||
Letter | 04/15/2014 | Satisfied | COLSON_NJ_1 | Non-Compliance | |||||||
Issue Document | 11/27/2013 | Satisfied | ROGGELIN_EM_1 | Closure | |||||||
Site Inspection | 03/25/2013 | In Compliance | JUEDES_HC_1 | 0/1 | Routine Compliance | ||||||
Site Inspection | 11/07/2012 | Minor Out of Compliance | STRAUSS_RH_1 | 0/1 | Installation | ||||||
Letter | 11/07/2012 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||||||
Site Inspection | 11/07/2012 | Minor Out of Compliance | STRAUSS_RH_1 | 0/1 | Closure | ||||||
Letter | 11/07/2012 | Satisfied | STRAUSS_RH_1 | Non-Compliance | |||||||
Site Inspection | 07/19/2012 | Major Out of Compliance | LONGEN_JL_1 | 0/1 | Non-Compliance | ||||||
Letter | 07/19/2012 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Incident | 07/18/2012 | Has not led to Discharge | LONGEN_JL_1 | Incident | |||||||
Letter | 03/26/2012 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Site Inspection | 03/26/2012 | Minor Out of Compliance | LONGEN_JL_1 | 0/1 | Routine Compliance | ||||||
Emergency Preparedness Information | 03/26/2012 | Satisfied | LONGEN_JL_1 | Routine Compliance | |||||||
Site Inspection | 02/25/2011 | In Compliance | LONGEN_JL_1 | 0/1 | Non-Compliance | ||||||
Emergency Preparedness Information | 02/15/2011 | Satisfied | LONGEN_JL_1 | Routine Compliance | |||||||
Site Inspection | 02/15/2011 | Minor Out of Compliance | LONGEN_JL_1 | 0/1 | Routine Compliance | ||||||
Letter | 02/15/2011 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Site Inspection | 03/17/2010 | In Compliance | LONGEN_JL_1 | 0/1 | Routine Compliance | ||||||
Record Document | 04/16/2009 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Site Inspection | 01/22/2009 | Minor Out of Compliance | LONGEN_JL_1 | 0/1 | Routine Compliance | ||||||
Letter | 01/22/2009 | Satisfied | LONGEN_JL_1 | Non-Compliance | |||||||
Site Inspection | 01/08/2008 | In Compliance | BARNETT_JX | 0/1 | Routine Compliance | ||||||
Emergency Preparedness Information | 01/08/2008 | Satisfied | BARNETT_JX | Routine Compliance | |||||||
Letter | 02/23/2007 | Satisfied | BARNETT_JX | Non-Compliance | |||||||
Emergency Preparedness Information | 02/07/2007 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||||||
Site Inspection | 01/29/2007 | Major Out of Compliance | BARNETT_JX | 0/1 | Routine Compliance | ||||||
Emergency Preparedness Information | 09/20/2006 | Satisfied | STRAUSS_RH_1 | Routine Compliance | |||||||
Record Document | 06/16/2006 | Satisfied | BARNETT_JX | Non-Compliance | |||||||
No Open AOCs Found | |||||||||||
Open Violations | |||||||||||
Insp Date | Vio # | Significance | Violation Text | Corrective Action | |||||||
01/13/2025 | 6012 | SNC-A | 2.9 No financial responsibility instrument or expired instrument for > 180 days. | Please obtain means of financial responsibility and submit financial responsibility records, including DEP forms, to this office. | |||||||
01/13/2025 | 6076 | Minor | 4.7 Requirements not met for out-of-service systems. | Remove all regulated substances so that no more than one inch in depth or 0.3 percent by weight of regulated substances remains in the storage tank. | |||||||
04/15/2023 | 6013 | Minor | 2.10 Appropriate paperwork for financial responsibility improperly completed or maintained. | Provide a current storage tank insurance policy and a completed Certification of Financial Responsibility Part P form. | |||||||
04/02/2021 | 4068 | Minor | 4.3 Storage tank system has a not repaired component which has or could cause a release or discharge. | Please repair the Regular sump piping fitting and inspect/repair as necessary the Premium sump piping fitting, and perform post-repair integrity testing of the sumps | |||||||
04/02/2021 | 4077 | Minor | 4.12 Spill containment, sumps, and interstices not accessible. Water/regulated substances not timely removed. Petroleum contact water not properly managed. | Please remove the petroleum contact water from the sumps and provide documentation of its proper disposal | |||||||
01/18/2019 | 4001 | Minor | 2.2 Operator certification requirements not met. | Please have all applicable personnel complete the required training and provide certificates for personnel completing the training | |||||||
01/18/2019 | 4076 | Minor | 4.11 Failure to conduct required periodic containment and interstitial integrity testing. | Please provide current test results and ensure the spill buckets are tested annually at intervals not exceeding 12 months, and the STP and dispenser sumps are tested every 3 years | |||||||
01/18/2019 | 4079 | Minor | 2.7 Records requiring 3 years documentation period not kept by facility. | Please ensure all required records are kept for a minimum period of 3 years | |||||||
01/18/2019 | 4067 | Minor | 4.2 Release detection devices not tested annually. | Please provide current test results and all tests completed since 9/13/2016; please ensure that the leak detectors are tested annually at intervals not exceeding 12 months | |||||||
01/18/2019 | 4078 | Minor | 2.6 Required records not available within 5 working days notice. | Please ensure all required records are available within 5 days notice | |||||||
01/18/2019 | 4057 | Minor | 4.31 Overfill protection devices not registered or tested annually. | Please provide current test results of the overfill drop-tube shut-off valves and remove the ball float overfill valves; please ensure operability testing of the overfill prevention valves is completed annually at intervals not exceeding 12 months | |||||||