Florida Department of Environmental Protection Bob Martinez Center 2600 Blair Stone Road Tallahassee, Florida 32399-2400 |
Storage Tanks & Contamination Monitoring Information |
||||||
Cover Page Report | |||||||
Report Run Date: 02/02/2025 Last Data Refresh: 02/01/2025 Report Generated from DOPPLER | |||||||
District | Southeast | Type | County Government | ||||
County | Miami-Dade | Status | OPEN | ||||
ID | 9600034 | Latitude | 25° 47' 38.03 | ||||
Name |
MIAMI-DADE AVIATION DEPT MDAD GSA VFF 4300 NW 20TH ST BLDG 3051 MIA |
Longitude | 80° 16' 5.4754 | ||||
MIAMI, FL 33159 | LL Method | DPHO | |||||
Contact | PEDRO F HERNANDEZ | LL Status | REVIEWED | ||||
Phone | (305) 876-7928 | Status Date | 04/09/2003 | ||||
Account Owner Information | |||||||
Name | MIAMI-DADE AVIATION DEPT PO BOX 25504 Miami, FL 33102-5504 |
Effective Date | 01/11/1996 | ||||
Contact | GABRIEL GARCIA | ||||||
Phone | (305) 869-3615 | ||||||
GAGARCIA@FLYMIA.COM | |||||||
Placard # / Date | 698325 - 07/01/2024 | ||||||
No Property Owner Information Found | |||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
10A | 10000 | Vehicular Diesel (D) | 12/01/1995 | ABOVEGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(A) Ball check valve (C) Steel (M) Spill containment bucket (N) Flow shut-Off (R) Double wall - tank jacket |
(C) Fiberglass (F) Double wall (J) Pressurized piping system |
(B) Site Suitabilitiy Plan exemption (F) Monitor dbl wall tank space (K) Monitor dbl wall pipe space (L) Automatic tank gauging - USTs |
|||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
11A | 10000 | Unleaded Gas (B) | 12/01/1995 | ABOVEGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(A) Ball check valve (C) Steel (M) Spill containment bucket (N) Flow shut-Off (R) Double wall - tank jacket |
(C) Fiberglass (F) Double wall (J) Pressurized piping system |
(B) Site Suitabilitiy Plan exemption (F) Monitor dbl wall tank space (K) Monitor dbl wall pipe space (L) Automatic tank gauging - USTs |
|||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
12A | 10000 | Unleaded Gas (B) | 12/01/1995 | ABOVEGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(A) Ball check valve (C) Steel (M) Spill containment bucket (N) Flow shut-Off (R) Double wall - tank jacket |
(C) Fiberglass (F) Double wall (J) Pressurized piping system |
(B) Site Suitabilitiy Plan exemption (F) Monitor dbl wall tank space (K) Monitor dbl wall pipe space (L) Automatic tank gauging - USTs |
|||||
Insurance Documents | |||||||
FR Type | Effective Date | Expiration Date | Company Name | ||||
LOCAL GOVERNMENTS - BOND RATING TEST | 02/01/2024 | 01/31/2025 | |||||
LOCAL GOVERNMENTS - BOND RATING TEST | 02/01/2023 | 01/31/2024 | |||||
LOCAL GOVERNMENTS - BOND RATING TEST | 02/01/2022 | 01/31/2023 | |||||
LOCAL GOVERNMENTS - BOND RATING TEST | 02/01/2021 | 01/31/2022 | |||||
LOCAL GOVERNMENTS - BOND RATING TEST | 02/01/2018 | 01/31/2019 | |||||
LOCAL GOVERNMENTS - BOND RATING TEST | 01/15/2015 | 07/21/2016 | |||||
LOCAL GOVERNMENTS - BOND RATING TEST | 01/01/2012 | 12/31/2014 | |||||
LOCAL GOVERNMENTS - BOND RATING TEST | 01/01/2012 | 02/05/2014 | |||||
LOCAL GOVERNMENTS - BOND RATING TEST | 10/01/2010 | 12/31/2011 | |||||
LOCAL GOVERNMENTS - FINANCIAL TEST | 01/01/2006 | 12/31/2006 | |||||
Legacy Compliance Activity Information | |||||||
Activity Code |
Date Initiated |
Date Completed |
Results | Inspector | AST/UST Count |
Description | |
TCI | 09/28/2005 | 10/17/2005 | IN-COMPLIANCE | ECT/BUSEN_K | 3/0 | COMPLIANCE ASSURANCE | |
MEET | 05/04/2005 | 05/06/2005 | COMPLIANCE ASSURANCE | ||||
TCI | 09/28/2004 | 11/04/2004 | SIGNIFICANT OUT-OF-COMPLIANCE | BUSEN_K | 3/0 | COMPLIANCE ASSURANCE | |
RRBD | 07/03/2003 | 07/07/2003 | COMPLIANCE ASSURANCE | ||||
TCI | 06/03/2003 | 06/09/2003 | MINOR OUT-OF-COMPLIANCE | RAINEY_A | 3/0 | COMPLIANCE ASSURANCE | |
TCI | 02/24/2003 | 02/24/2003 | IN-COMPLIANCE | RAINEY_A | 1/0 | COMPLIANCE ASSURANCE | |
Completion Notes TCI ENTERED ONLY TO CLOSE VIOLATIONS AND ENTER CWOE; NO PHYSICAL INSPECTION PERFORMED | |||||||
TCI | 10/01/1999 | 10/04/1999 | SIGNIFICANT OUT-OF-COMPLIANCE | RAINEY_A | 3/0 | COMPLIANCE ASSURANCE | |
Compliance Activity Information | |||||||
Activity Code |
Date Completed |
Results | Inspector | AST/UST Count |
Description | ||
Meeting | 12/03/2024 | Satisfied | MAIB_R | Enforcement | |||
Enforcement Referral | 10/23/2024 | Accepted | MAIB_R | Enforcement | |||
Site Inspection | 08/08/2024 | Major Out of Compliance | MAIB_R | 3/0 | Routine Compliance | ||
Electronic Communication | 08/30/2022 | Satisfied | BORGESPADRO_A | Routine Compliance | |||
Electronic Communication | 08/30/2022 | Satisfied | BORGESPADRO_A | Routine Compliance | |||
Letter | 10/19/2021 | Satisfied | WILLIAMS_CEW | Compliance Assistance | |||
Electronic Communication | 08/05/2021 | Satisfied | WILLIAMS_CEW | Routine Compliance | |||
Site Inspection | 07/21/2021 | Major Out of Compliance | WILLIAMS_CEW | 3/0 | Routine Compliance | ||
Letter | 11/16/2018 | Satisfied | WILLIAMS_CEW | Compliance Assistance | |||
Letter | 11/16/2018 | Satisfied | WILLIAMS_CEW | Routine Compliance | |||
Site Inspection | 09/12/2018 | Minor Out of Compliance | WILLIAMS_CEW | 3/0 | Routine Compliance | ||
Site Inspection | 06/22/2016 | In Compliance | DOLAN_J | 3/0 | Routine Compliance | ||
Record Document | 04/05/2013 | Satisfied | RAHRIG_T | Routine Compliance | |||
Electronic Communication | 04/04/2013 | Satisfied | RAHRIG_T | Routine Compliance | |||
Site Inspection | 04/02/2013 | In Compliance | RAHRIG_T | 3/0 | Routine Compliance | ||
Electronic Communication | 03/28/2013 | Satisfied | RAHRIG_T | Routine Compliance | |||
Meeting | 10/16/2012 | Satisfied | RAHRIG_T | Non-Compliance | |||
Electronic Communication | 09/05/2012 | Satisfied | RAHRIG_T | Non-Compliance | |||
Record Document | 09/05/2012 | Satisfied | RAHRIG_T | Non-Compliance | |||
Issue Document | 06/22/2012 | Satisfied | RAHRIG_T | Routine Compliance | |||
Letter | 06/15/2012 | Satisfied | RAHRIG_T | Non-Compliance | |||
Site Inspection | 06/08/2012 | Major Out of Compliance | RAHRIG_T | 3/0 | Routine Compliance | ||
Electronic Communication | 05/17/2012 | Satisfied | RAHRIG_T | Routine Compliance | |||
Electronic Communication | 10/20/2010 | Satisfied | RAHRIG_T | Non-Compliance | |||
Electronic Communication | 10/19/2010 | Satisfied | RAHRIG_T | Routine Compliance | |||
Letter | 10/19/2010 | Satisfied | RAHRIG_T | Non-Compliance | |||
Site Inspection | 10/19/2010 | Minor Out of Compliance | RAHRIG_T | 3/0 | Routine Compliance | ||
Site Inspection | 09/26/2006 | In Compliance | BUSEN_K | 3/0 | Routine Compliance | ||
No Open AOCs Found | |||||||
Open Violations | |||||||
Insp Date | Vio # | Significance | Violation Text | Corrective Action | |||
07/31/2024 | 7012 | SNC-B | 3.3 Incident investigation not initiated within 24-hours (or by next business day) to determine if discharge occurred. | An incident investigation needs to be performed, and an incident notification form needs to be submitted to the department. | |||
07/18/2024 | 7095 | Minor | 1.14 Records requiring 3 year documentation period not kept by facility. | Repair records for the tank system need to be provided. | |||
07/16/2024 | 7076 | SNC-A | 3.2 Not repaired component or piping which has cause a discharge or release. | The dispenser sumps need to be taken out of service, repairs completed, and an investigation shall be conducted in accordance with F.A.C 62-762.801 and Instructions for Conducting Sampling During Aboveground Storage Tank Closure, July 2019 Edition, to ensure the discharge did not enter the environment. | |||
07/16/2024 | 7022 | Minor | 3.4 Secondary containment constructed of concrete not in accordance with standards or not impervious. | The remote fill concrete spill containment needs to be repaired and integrity test performed. | |||
07/16/2024 | 7083 | SNC-B | 3.8 Storage tank system not taken out-of-service when repairs cannot be made within 90 days. | The six dispenser sumps, piping sump and spill containment for the remote fill need to be taken out of service until the proper repairs are made and integrity testing completed. | |||
07/16/2024 | 7047 | SNC-B | 3.11 Piping sumps not meeting performance requirements or installed to allow for release detection. | The piping sump need to be repaired to manufacturer standards and integrity test performed. | |||
07/16/2024 | 7045 | Minor | 3.6 Dispensers not installed and maintained according to standards. | The six dispenser sumps need to be repaired to manufacturer standards and integrity tests performed. | |||
07/16/2024 | 7081 | SNC-B | 3.7 Piping that is damaged which has not caused a discharge is not replaced. | The ASTs STP piping and integral piping needs to be repaired to manufacturer standards. | |||
07/16/2024 | 7075 | SNC-B | 3.1 Not repaired component or piping which has not caused a discharge or release. | The testing boots in the piping sump need to be pulled back. | |||
No Discharges Found |