Florida Department of Environmental Protection Bob Martinez Center 2600 Blair Stone Road Tallahassee, Florida 32399-2400 |
Storage Tanks & Contamination Monitoring Information |
|||||
Cover Page Report | |||||||
Report Run Date: 05/09/2025 Last Data Refresh: 05/08/2025 Report Generated from DOPPLER | |||||||
District | Northeast | Type | Local Government | ||||
County | Taylor | Status | OPEN | ||||
ID | 9700454 | Latitude | 30° 4' 36.9494 | ||||
Name |
PERRY-FOLEY AIRPORT 511 INDUSTRIAL PARK DR |
Longitude | 83° 34' 24.5698 | ||||
PERRY, FL 32348 | LL Method | DPHO | |||||
Contact | BILL ROBERTS | LL Status | REVIEWED | ||||
Phone | (850) 838-3519 | Status Date | 05/30/2024 | ||||
Account Owner Information | |||||||
Name | TAYLOR CNTY BD OF COMMISSIONERS PO BOX 620 PERRY, FL 32348 |
Effective Date | 04/01/1997 | ||||
Contact | BRENDA BRANNAN / LAWANDA PEMBERTON 850-843-5381 | ||||||
Phone | (850) 838-3528 | ||||||
ROAD.MANAGER@TAYLORCOUNTYGOV.COM | |||||||
Placard # / Date | 703655 - 11/25/2024 | ||||||
No Property Owner Information Found | |||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
1 | 12000 | Aviation Gas (E) | 03/01/1997 | ABOVEGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(C) Steel (I) Double wall (M) Spill containment bucket (P) Level gauges/alarms |
(A) Abv, no soil contact (B) Steel/galvanized metal (K) Dispenser liners |
(4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (Q) Visual inspection of ASTs |
|||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
2 | 10000 | Jet Fuel (F) | 12/01/2003 | ABOVEGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(A) Ball check valve (C) Steel (I) Double wall (M) Spill containment bucket (O) Tight fill (P) Level gauges/alarms |
(A) Abv, no soil contact (B) Steel/galvanized metal (J) Pressurized piping system (K) Dispenser liners |
(4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (Q) Visual inspection of ASTs |
|||||
Insurance Documents | |||||||
FR Type | Effective Date | Expiration Date | Company Name | ||||
INSURANCE | 04/27/2021 | 04/27/2022 | COMMERCE & INDUSTRY INSURANCE CO | ||||
INSURANCE | 04/27/2020 | 04/27/2021 | COMMERCE & INDUSTRY INSURANCE CO | ||||
INSURANCE | 04/27/2018 | 04/27/2019 | COMMERCE & INDUSTRY INSURANCE CO | ||||
INSURANCE | 04/27/2017 | 04/27/2018 | COMMERCE & INDUSTRY INSURANCE CO | ||||
INSURANCE | 04/27/2015 | 04/27/2016 | COMMERCE & INDUSTRY | ||||
INSURANCE | 04/27/2013 | 04/27/2014 | COMMERCE & INDUSTRY | ||||
INSURANCE | 04/27/2011 | 04/27/2012 | COMMERCE & INDUSTRY | ||||
INSURANCE | 04/27/2010 | 04/27/2011 | COMMERCE & INDUSTRY | ||||
INSURANCE | 04/27/2009 | 04/27/2010 | COMMERCE & INDUSTRY | ||||
INSURANCE | 04/27/2008 | 04/27/2009 | COMMERCE & INDUSTRY | ||||
Legacy Compliance Activity Information | |||||||
Activity Code |
Date Initiated |
Date Completed |
Results | Inspector | AST/UST Count |
Description | |
RRBD | 09/08/2005 | IN-COMPLIANCE | PAUL HUTCHERSON | 1/0 | COMPLIANCE ASSURANCE | ||
NCLI | 08/10/2005 | 08/11/2005 | PAUL HUTCHERSON | 0/0 | COMPLIANCE ASSURANCE | ||
TCI | 08/09/2005 | 08/11/2005 | SIGNIFICANT OUT-OF-COMPLIANCE | PAUL HUTCHESON | 1/0 | COMPLIANCE ASSURANCE | |
TCI | 07/21/2004 | 09/30/2004 | IN-COMPLIANCE | GARRY ALLSHOUSE | 1/0 | COMPLIANCE ASSURANCE | |
Completion Notes TCI SATISFACTORY | |||||||
TCI | 07/25/2003 | 08/20/2003 | IN-COMPLIANCE | GARRY ALLSHOUSE | 1/0 | COMPLIANCE ASSURANCE | |
Completion Notes TCI IN COMPLIANCE | |||||||
TCI | 09/29/2001 | 10/02/2001 | IN-COMPLIANCE | MEISSNER_R | 1/0 | COMPLIANCE ASSURANCE | |
Completion Notes IN COMPLIANCE | |||||||
TCI | 11/09/2000 | 11/09/2000 | IN-COMPLIANCE | MEISSNER_R | 1/0 | COMPLIANCE ASSURANCE | |
Completion Notes NO VIOLATIONS FOUND | |||||||
TCI | 09/30/1999 | 10/20/1999 | IN-COMPLIANCE | MEISSNER_R | 1/0 | COMPLIANCE ASSURANCE | |
Completion Notes NO VIOLATIONS FOUND | |||||||
Compliance Activity Information | |||||||
Activity Code |
Date Completed |
Results | Inspector | AST/UST Count |
Description | ||
Enforcement Referral | 05/03/2024 | Accepted | ZIMMERMAN_RA_2 | Enforcement | |||
Electronic Communication | 01/27/2023 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Letter | 11/24/2021 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Site Inspection | 11/24/2021 | Minor Out of Compliance | ZIMMERMAN_RA_2 | 2/0 | Routine Compliance | ||
Electronic Communication | 11/24/2021 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Phone Conversation | 10/07/2021 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Record Document | 06/28/2021 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Letter | 06/28/2021 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Electronic Communication | 06/28/2021 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Letter | 12/07/2018 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Electronic Communication | 12/07/2018 | Satisfied | ZIMMERMAN_RA_2 | Compliance Assistance | |||
Site Inspection | 12/07/2018 | Minor Out of Compliance | ZIMMERMAN_RA_2 | 2/0 | Routine Compliance | ||
Electronic Communication | 11/28/2018 | Satisfied | ZIMMERMAN_RA_2 | Routine Compliance | |||
Site Inspection | 10/07/2015 | In Compliance | GRAHAM_DL_1 | 2/0 | Routine Compliance | ||
Phone Conversation | 09/11/2015 | Satisfied | GRAHAM_DL_1 | Routine Compliance | |||
Site Inspection | 08/30/2013 | In Compliance | GRAHAM_DL_1 | 1/0 | Routine Compliance | ||
Site Inspection | 11/03/2011 | In Compliance | GRAHAM_DL_1 | 1/0 | Routine Compliance | ||
Site Inspection | 11/12/2010 | In Compliance | GRAHAM_DL_1 | 1/0 | Routine Compliance | ||
Site Inspection | 11/03/2009 | In Compliance | GRAHAM_DL_1 | 1/0 | Routine Compliance | ||
Site Inspection | 10/15/2008 | In Compliance | GRAHAM_DL_1 | 1/0 | Routine Compliance | ||
Issue Document | 09/19/2008 | Satisfied | GRAHAM_DL_1 | Routine Compliance | |||
Site Inspection | 08/14/2007 | In Compliance | HUTCHERSON_P | 1/0 | Routine Compliance | ||
Site Inspection | 08/02/2006 | In Compliance | HUTCHERSON_P | 1/0 | Routine Compliance | ||
No Open AOCs Found | |||||||
Open Violations | |||||||
Insp Date | Vio # | Significance | Violation Text | Corrective Action | |||
11/24/2021 | 6053 | Minor | 4.7 Primary overfill protection not provided, registered, or tested as required. | Have the tanks primary overfill protection device tested and certified operational, email passing annual overfill protection device test certification to ACEPD. | |||
No Discharges Found |