DEP Logo Florida Department of
Environmental Protection


Bob Martinez Center
2600 Blair Stone Road
Tallahassee, Florida 32399-2400
Storage Tanks &
Contamination
Monitoring Information
 
Cover Page Report
Report Run Date: 04/19/2025        Last Data Refresh: 04/18/2025        Report Generated from DOPPLER
 
District South   Type    Retail Station
 
County Lee   Status    OPEN
 
ID 9700977   Latitude    26° 41' 47.8309
 
Name LITTLETON DELI
8671 LITTLETON RD
Longitude    81° 54' 6.8352
  NORTH FORT MYERS, FL 33903 LL Method    DPHO
 
Contact RAY RASHID   LL Status    REVIEWED
 
Phone (239) 656-1072   Status Date    12/24/2003
 
Account Owner Information
 
Name HAMZA PROPERTIES INC
8673 LITTLETON RD
NORTH FORT MYERS, FL 33903
Effective Date    04/23/2001
 
Contact RAY RASHID
 
Phone (941) 656-1072
 
Email
  Placard # / Date    697105 - 06/28/2024
Property Owner Information
 
Name SALEMEH, LOU
PO BOX 150973
CAPE CORAL, FL 33915
Effective Date    08/23/1999
 
Contact LOU SALEMEH
 
Phone
 
Email
 
 
 
 
 
 
 
 
 
Tank Tank Size Content Installed Placement Status
1 15000 Unleaded Gas (B) 08/01/1997 UNDERGROUND In Service (U)
 
Constructions   Pipings Monitorings
(A) Ball check valve
(F) Fiberglass clad steel
(I) Double wall
(L) Compartmented
(M) Spill containment bucket
(N) Flow shut-Off
(O) Tight fill
(P) Level gauges/alarms
  (B) Steel/galvanized metal
(J) Pressurized piping system
(K) Dispenser liners
(P) Internal pipe/internal sump riser
(2) Visual inspect pipe sumps
(4) Visual inspect dispenser liners
(F) Monitor dbl wall tank space
(H) Mechanical line leak detector
 
 
Insurance Documents
 
FR Type   Effective Date Expiration Date Company Name
INSURANCE   10/28/2019 10/28/2020 ACE AMERICAN INSURANCE COMPANY
INSURANCE   10/28/2018 10/28/2019 ACE AMERICAN INSURANCE COMPANY
INSURANCE   10/28/2017 10/28/2018 ACE AMERICAN INSURANCE COMPANY
INSURANCE   10/28/2016 10/28/2017 ACE
INSURANCE   09/24/2015 09/24/2016 ACE
INSURANCE   09/24/2014 09/24/2015 ACE
INSURANCE   09/24/2013 09/24/2014 ACE
INSURANCE   07/01/2012 07/01/2013 ACE
INSURANCE   07/01/2011 07/01/2012 ACE
INSURANCE   07/01/2010 07/01/2011 ACE
INSURANCE   08/27/1997 06/30/2010 ZURICH-AMERICAN
 
 
Legacy Compliance Activity Information
 
Activity
Code
Date
Initiated
Date
Completed
Results Inspector AST/UST
Count
Description
NCLI 11/04/2005 11/04/2005 S. JOHNSON 0/0 COMPLIANCE ASSURANCE
 
TCI 10/31/2005 11/04/2005 MINOR OUT-OF-COMPLIANCE S. JOHNSON 0/1 COMPLIANCE ASSURANCE
 
 Completion Notes PIPING - FLEX RD - MONTHLY VISUALS/VACUUM(12) 3/26/2005 - LLD TESTED/PASSED - UST ENVIRONMENTAL
 
TCI 10/07/2004 10/08/2004 IN-COMPLIANCE S JOHNSON/J SAIYA 0/1 COMPLIANCE ASSURANCE
 
 Completion Notes PIPING- DISPENSER PIPING LOCATED ON TANK RDRL- MONTHLY VISUALS/VACUUM (14)
 
RRBD 03/26/2004 03/26/2004 IN-COMPLIANCE S. JOHNSON 0/1 COMPLIANCE ASSURANCE
 
TCI 01/23/2004 01/26/2004 MINOR OUT-OF-COMPLIANCE S. JOHNSON 0/1 COMPLIANCE ASSURANCE
 
 Completion Notes PIPING - DISPENSERS LOCATED DIRECTLY ON TOP OF TANK AND DRAIN TO SUMPS. RDRL - MONTHLY VISUALS AND VACUUM GAUGE - READING 10PSI
 
TCR 04/15/2003 04/25/2003 IN-COMPLIANCE S JOHNSON/P DEMACK 0/1 COMPLIANCE ASSURANCE
 
TCI 03/04/2003 03/14/2003 SIGNIFICANT OUT-OF-COMPLIANCE DEMACK,P\JOHNSON,S 0/1 COMPLIANCE ASSURANCE
 
 Completion Notes PIPING-FLEX PIPE, SUMPS AND PIPING IS DIRECTLY ABOVE THE TANK AND BELOW THE DISPENSER. RDRL-VACUUM MONITORING AND MONTHLY VISUALS 05/22/2002-LINE LEAK DETECTORS TESTED/PASSED (PRECISION PETROLEUM)
 
TCI 05/08/2002 05/09/2002 MINOR OUT-OF-COMPLIANCE PECK/DEMACK 0/1 COMPLIANCE ASSURANCE
 
RRBD 04/12/2001 04/18/2001 HOENE 0/1 COMPLIANCE ASSURANCE
 
TCI 04/11/2001 04/11/2001 MINOR OUT-OF-COMPLIANCE HOENE 0/1 COMPLIANCE ASSURANCE
 
CWOE 07/13/2000 07/14/2000 HOENE 0/0 COMPLIANCE ASSURANCE
 
LTR 07/13/2000 07/14/2000 HOENE 0/1 COMPLIANCE ASSURANCE
 
 Completion Notes RECEIVED FAX OF THE INSURANCE
 
LTR 05/19/2000 05/19/2000 HOENE 0/1 COMPLIANCE ASSURANCE
 
 Completion Notes FACILITY LEASEE? REQUESTED AN 30 DAY EXTENSOIN DUE TO THE FACT THAT THE OWNER CARRIES THE INSURANCE AND IS OUT OF TOWN FOR 2-3 WEEKS.
 
TCI 04/14/2000 04/18/2000 SIGNIFICANT OUT-OF-COMPLIANCE HOENE 0/1 COMPLIANCE ASSURANCE
 
TCI 06/09/1999 07/01/1999 IN-COMPLIANCE HOENE 0/0 COMPLIANCE ASSURANCE
 
 
 
Compliance Activity Information
 
Activity
Code
Date
Completed
Results Inspector AST/UST
Count
Description
Letter 10/20/2023 Satisfied PARKS_J_4 Compliance Assistance
 
Phone Conversation 10/20/2023 Satisfied PARKS_J_4 Routine Compliance
 
Site Inspection 10/20/2023 Major Out of Compliance PARKS_J_4 0/1 Routine Compliance
 
Site Inspection 04/22/2022 Major Out of Compliance PARKS_J_4 0/1 Routine Compliance
 
Phone Conversation 04/22/2022 Satisfied PARKS_J_4 Routine Compliance
 
Site Inspection 04/29/2020 Major Out of Compliance SAUTTER_MA_2 0/1 Routine Compliance
 
Letter 04/29/2020 Satisfied SAUTTER_MA_2 Compliance Assistance
 
Electronic Communication 04/29/2020 Satisfied SAUTTER_MA_2 Compliance Assistance
 
Record Document 12/06/2017 Satisfied ZIMMERMAN_CA_1 Compliance Assistance
 
Letter 04/28/2017 Satisfied JOHNSON_SG_1 Non-Compliance
 
Site Inspection 04/28/2017 Minor Out of Compliance JOHNSON_SG_1 0/1 Routine Compliance
 
Site Inspection 05/08/2015 In Compliance JOHNSON_SG_1 0/1 Routine Compliance
 
Record Document 03/04/2013 Satisfied ZIMMERMAN_CA_1 Non-Compliance
 
Letter 12/21/2012 Satisfied ZIMMERMAN_CA_1 Non-Compliance
 
Site Inspection 12/21/2012 Minor Out of Compliance ZIMMERMAN_CA_1 0/1 Routine Compliance
 
Emergency Preparedness Information 12/20/2012 Satisfied ZIMMERMAN_CA_1 Routine Compliance
 
Site Inspection 12/05/2011 In Compliance ZIMMERMAN_CA_1 0/1 Routine Compliance
 
Phone Conversation 02/09/2011 Satisfied ZIMMERMAN_CA_1 Non-Compliance
 
Letter 12/01/2010 Satisfied ZIMMERMAN_CA_1 Non-Compliance
 
Site Inspection 12/01/2010 Minor Out of Compliance ZIMMERMAN_CA_1 0/1 Routine Compliance
 
Record Document 03/12/2010 Satisfied JOHNSON_SG_1 Non-Compliance
 
Letter 11/13/2009 Satisfied JOHNSON_SG_1 Non-Compliance
 
Site Inspection 11/09/2009 Minor Out of Compliance JOHNSON_SG_1 0/1 Routine Compliance
 
Site Inspection 11/13/2008 In Compliance JOHNSON_SG_1 0/1 Routine Compliance
 
Site Inspection 11/07/2007 In Compliance JOHNSON_SG_1 0/1 Routine Compliance
 
Emergency Preparedness Information 02/05/2007 Satisfied ZIMMERMAN_CA_1 Routine Compliance
 
Site Inspection 10/25/2006 In Compliance JOHNSON_SG_1 0/1 Routine Compliance
 
Emergency Preparedness Information 09/20/2006 Satisfied JOHNSON_SG_1 Routine Compliance
 
Site Inspection 07/28/2006 In Compliance RUPP_SS 0/1 Non-Compliance
 
 
 
No Open AOCs Found
 
 
Open Violations
 
Insp Date Vio # Significance Violation Text Corrective Action
04/22/2022 6002 Minor 2.1 Operator Training records not available. Provide training certificates for review.
 
04/22/2022 6001 Minor 2.1 No reasonable access provided. There was no access to the sump containing the vent line.
 
04/22/2022 6062 Minor 2.5 Release detection devices not tested annually. Have all the tests conducted and submit the results to the county inspector.
 
04/22/2022 6012 SNC-A 2.9 No financial responsibility instrument or expired instrument for > 180 days. Provide a certificate of Financial Responsibility for review.
 
04/29/2020 4077 Minor 4.12 Spill containment, sumps, and interstices not accessible. Water/regulated substances not timely removed. Petroleum contact water not properly managed. Repair or replace the product line and/or the STP sump lid so as to offer access to the STP sump.
 
04/29/2020 4059 SNC-B 4.1 Release detection, including visual inspections not being conducted monthly (not to exceed 35 days.) For electronically monitored sumps, visual inspections not conducted every 6 months. This violation may lead to Placard Revocation and Delivery Prohibition. Have the monthly visual inspections conducted each month (fewer than 35 days between consecutive inspections) and submit the documents for May, June and July 2020 to the county inspector
 
04/29/2020 4057 Minor 4.31 Overfill protection devices not registered or tested annually. Have all of the required tests conducted and submit the results to the county inspector
 
04/29/2020 4067 Minor 4.2 Release detection devices not tested annually. Have all of the required tests conducted and submit the results to the county inspector
 
 
 
No Discharges Found