District | Central | Type | Retail Station | ||||
County | Lake | Status | OPEN | ||||
ID | 9810660 | Latitude | 28° 30' .5742 | ||||
Name |
CIRCLE K #2704884 4311 S HWY 27 |
Longitude | 81° 43' 6.3218 | ||||
CLERMONT, FL 34711 | LL Method | DPHO | |||||
Contact | GRAHAM BIGGS | LL Status | REVIEWED | ||||
Phone | (919) 774-6700 | Status Date | 09/18/2023 | ||||
Account Owner Information | |||||||
Name | CIRCLE K STORES INC 1100 Situs Ct Raleigh, NC 27606-5446 |
Effective Date | 12/11/2013 | ||||
Contact | IRA LEWIS | ||||||
Phone | (423) 400-2480 | ||||||
ILEWIS@CIRCLEK.COM | |||||||
Placard # / Date | 698063 - 06/29/2024 | ||||||
No Property Owner Information Found | |||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
1 | 20000 | Unleaded Gas (B) | 08/01/2008 | UNDERGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(E) Fiberglass (I) Double wall (L) Compartmented (M) Spill containment bucket (N) Flow shut-Off (O) Tight fill (P) Level gauges/alarms |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (K) Monitor dbl wall pipe space |
|||||
Tank | Tank Size | Content | Installed | Placement | Status | ||
2 | 20000 | Unleaded Gas (B) | 08/01/2008 | UNDERGROUND | In Service (U) | ||
Constructions | Pipings | Monitorings | |||||
(E) Fiberglass (I) Double wall (L) Compartmented (M) Spill containment bucket (N) Flow shut-Off (O) Tight fill (P) Level gauges/alarms |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(2) Visual inspect pipe sumps (4) Visual inspect dispenser liners (F) Monitor dbl wall tank space (K) Monitor dbl wall pipe space |
|||||
Insurance Documents | |||||||
FR Type | Effective Date | Expiration Date | Company Name | ||||
GUARANTEE | 04/24/2022 | 08/21/2023 | |||||
INSURANCE | 12/01/2020 | 12/01/2021 | NAVIGATORS SPECIALTY INSURANCE CO | ||||
INSURANCE | 12/01/2019 | 12/01/2020 | NAVIGATORS SPECIALTY INSURANCE CO | ||||
INSURANCE | 12/01/2018 | 12/01/2019 | IRONSHORE SPECIALTY INSURANCE CO | ||||
INSURANCE | 12/01/2017 | 12/01/2018 | IRONSHORE SPECIALTY INSURANCE CO | ||||
INSURANCE | 12/01/2016 | 12/01/2017 | IRONSHORE SPECIALTY INSURANCE CO | ||||
INSURANCE | 12/01/2014 | 12/01/2015 | IRONSHORE SPECIALTY INSURANCE CO | ||||
SELF-INSURANCE - LETTER FROM CHIEF FINANCIAL OFFICER | 03/20/2012 | 03/20/2013 | |||||
SELF-INSURANCE - LETTER FROM CHIEF FINANCIAL OFFICER | 03/20/2011 | 03/20/2012 | |||||
SELF-INSURANCE - LETTER FROM CHIEF FINANCIAL OFFICER | 03/20/2010 | 03/20/2011 | |||||
SELF-INSURANCE - LETTER FROM CHIEF FINANCIAL OFFICER | 03/20/2009 | 03/20/2010 | |||||
SELF-INSURANCE - LETTER FROM CHIEF FINANCIAL OFFICER | 03/20/2008 | 03/20/2009 | |||||
No Legacy Data Found | |||||||
Compliance Activity Information | |||||||
Activity Code |
Date Completed |
Results | Inspector | AST/UST Count |
Description | ||
Letter | 03/07/2025 | Satisfied | HALL_DK | Enforcement | |||
Enforcement Referral | 06/21/2024 | Accepted | GREGORY_JW_1 | Enforcement | |||
Electronic Communication | 02/29/2024 | Satisfied | GREGORY_JW_1 | Compliance Assistance | |||
Electronic Communication | 02/14/2024 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Electronic Communication | 02/14/2024 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Electronic Communication | 02/09/2024 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Site Inspection | 08/03/2023 | Major Out of Compliance | COX_CD_1 | 0/2 | Routine Compliance | ||
Letter | 08/03/2023 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Electronic Communication | 07/24/2023 | Satisfied | COX_CD_1 | Routine Compliance | |||
Letter | 03/11/2022 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Electronic Communication | 03/11/2022 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Electronic Communication | 03/11/2022 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Site Inspection | 09/24/2021 | Minor Out of Compliance | COX_CD_1 | 0/2 | Routine Compliance | ||
Letter | 09/24/2021 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Electronic Communication | 09/13/2021 | Satisfied | COX_CD_1 | Routine Compliance | |||
Electronic Communication | 06/29/2021 | Satisfied | COX_CD_1 | Routine Compliance | |||
Letter | 10/24/2019 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Electronic Communication | 10/24/2019 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Letter | 10/24/2019 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Electronic Communication | 10/08/2019 | Satisfied | COX_CD_1 | Compliance Assistance | |||
Site Inspection | 09/06/2019 | Major Out of Compliance | COX_CD_1 | 0/2 | Routine Compliance | ||
Letter | 09/06/2019 | Satisfied | COX_CD_1 | Non-Compliance | |||
Electronic Communication | 08/07/2019 | Satisfied | COX_CD_1 | Routine Compliance | |||
Site Inspection | 04/13/2017 | In Compliance | COX_CD_1 | 0/2 | Routine Compliance | ||
Electronic Communication | 04/04/2017 | Satisfied | COX_CD_1 | Routine Compliance | |||
Document Management | 12/01/2015 | Complete | MOORHEAD_SB_1 | Routine Compliance | |||
Site Inspection | 04/23/2015 | In Compliance | COX_CD_1 | 0/2 | Routine Compliance | ||
Record Document | 08/21/2013 | Satisfied | MOORHEAD_SB_1 | Routine Compliance | |||
Document Management | 01/10/2013 | Complete | COX_CD_1 | Routine Compliance | |||
Document Management | 01/10/2013 | Complete | COX_CD_1 | Routine Compliance | |||
Document Management | 01/10/2013 | Complete | COX_CD_1 | Routine Compliance | |||
Site Inspection | 01/09/2013 | In Compliance | COX_CD_1 | 0/2 | Routine Compliance | ||
Record Document | 09/11/2012 | Satisfied | MOORHEAD_SB_1 | Routine Compliance | |||
Site Inspection | 01/19/2012 | In Compliance | ZIMMERMAN_RA_1 | 0/2 | Non-Compliance | ||
Site Inspection | 12/02/2011 | Minor Out of Compliance | ZIMMERMAN_RA_1 | 0/2 | Routine Compliance | ||
Letter | 12/02/2011 | Satisfied | ZIMMERMAN_RA_1 | Non-Compliance | |||
Incident | 11/23/2011 | Has not led to Discharge | ZIMMERMAN_RA_1 | Incident | |||
Site Inspection | 01/03/2011 | In Compliance | COX_CD_1 | 0/2 | Non-Compliance | ||
Site Inspection | 12/13/2010 | In Compliance | ZIMMERMAN_RA_1 | 0/2 | Routine Compliance | ||
Site Inspection | 12/03/2009 | In Compliance | ZIMMERMAN_RA_1 | 0/2 | Routine Compliance | ||
Record Document | 04/15/2009 | Satisfied | ZIMMERMAN_RA_1 | Installation | |||
Phone Conversation | 04/06/2009 | Satisfied | COX_CD_1 | Non-Compliance | |||
Phone Conversation | 03/27/2009 | Satisfied | COX_CD_1 | Non-Compliance | |||
Site Inspection | 12/10/2008 | In Compliance | ZIMMERMAN_RA_1 | 0/2 | Installation | ||
No Open AOCs Found | |||||||
Open Violations | |||||||
Insp Date | Vio # | Significance | Violation Text | Corrective Action | |||
08/03/2023 | 6063 | SNC-B | 4.1 Not repaired or isolated component or piping which has not caused a discharge or release. | Investigate the incident and resolve the issue that is causing an alarm. File an INF and investigate the annular alarm that started intermittently in April 2023. | |||
07/28/2023 | 6066 | Minor | 4.4 Not repaired per applicable standards. | Clean and re-coat all of the components in the regular and premium STP sumps, especially the electrical conduits. Remove the water from the premium and east diesel's spill bucket secondaries and vacuum test the buckets. Repair if needed. Seal the ATG lids better to reduce the fumes in the sumps. | |||
No Discharges Found |