Report Run Date: 05/09/2025        Last Data Refresh: 05/08/2025        Report Generated from DOPPLER
 
District South   Type    Local Government
 
County Collier   Status    OPEN
 
ID 9811064   Latitude    26° 19' 25.5334
 
Name AVE MARIA UTILITY COMPANY WTP
5325 AVE MARIA BLVD
Longitude    81° 26' 25.5072
  AVE MARIA, FL 34142-9510 LL Method    DPHO
 
Contact TIM SCHLIEF   LL Status    REVIEWED
 
Phone (239) 825-1627   Status Date    09/17/2010
 
Account Owner Information
 
Name AVE MARIA UTILITY COMPANY
5076 ANNUNCIATION CIR
IMMOKALEE, FL 34142-9658
Effective Date    06/10/2016
 
Contact DAVID GENSON
 
Phone (239) 348-0248
 
Email TIM@AMUC.COM
  Placard # / Date    686209 - 06/10/2024
Property Owner Information
 
Name AVE MARIA UTILITY COMPANY
5076 ANNUNCIATION CIR
IMMOKALEE, FL 34142-9658
Effective Date    02/06/2009
 
Contact DAVID GENSON
 
Phone (239) 348-0248
 
Email TIM@AMUC.COM
 
 
 
 
 
 
 
 
 
Tank Tank Size Content Installed Placement Status
1 4000 Emerg Generator Diesel (G) 04/01/2006 ABOVEGROUND In Service (U)
 
Constructions   Pipings Monitorings
(C) Steel
(I) Double wall
(M) Spill containment bucket
(O) Tight fill
(P) Level gauges/alarms
  (X) No piping associated w/tank (F) Monitor dbl wall tank space
(I) Not required
(Q) Visual inspection of ASTs
 
 
Tank Tank Size Content Installed Placement Status
2 8000 Mineral Acid (U) 04/01/2006 ABOVEGROUND In Service (U)
 
Constructions   Pipings Monitorings
(C) Steel
(K) AST containment
(O) Tight fill
(P) Level gauges/alarms
  (B) Steel/galvanized metal (D) SPCC Plan
(Q) Visual inspection of ASTs
 
 
Tank Tank Size Content Installed Placement Status
3 6000 Hazardous Substance (T) 04/01/2006 ABOVEGROUND In Service (U)
 
Constructions   Pipings Monitorings
(C) Steel
(K) AST containment
(P) Level gauges/alarms
  (A) Abv, no soil contact
(B) Steel/galvanized metal
(X) None
 
 
Insurance Documents
 
FR Type   Effective Date Expiration Date Company Name
INSURANCE   FCCI INSURANCE COMPANY
INSURANCE   07/30/2022 07/30/2025 EVANSTON INSURANCE COMPANY
INSURANCE   07/30/2017 07/30/2022 STEADFAST INSURANCE COMPANY
INSURANCE   07/30/2017 07/30/2022 ZURICH NORTH AMERICA
INSURANCE   05/01/2014 05/01/2015 GREENWICH
INSURANCE   05/01/2013 05/01/2014 GREENWICH
INSURANCE   05/01/2011 05/01/2012 INDIAN HARBOR
INSURANCE   07/30/2007 07/30/2012 ZURICH-AMERICAN
 
 
No Legacy Data Found
 
 
Compliance Activity Information
 
Activity
Code
Date
Completed
Results Inspector AST/UST
Count
Description
Enforcement Referral 11/12/2024 Accepted STANDIFORD_JA Enforcement
 
Record Document 02/28/2024 Satisfied STANDIFORD_JA Compliance Assistance
 
Letter 02/02/2024 Satisfied STANDIFORD_JA Compliance Assistance
 
Site Inspection 01/29/2024 Minor Out of Compliance STANDIFORD_JA 2/0 Routine Compliance
 
Site Inspection 08/25/2020 In Compliance KWIAT_R 2/0 Routine Compliance
 
Issue Document 09/07/2018 Satisfied HERNANDEZ_N Routine Compliance
 
Site Inspection 09/06/2018 In Compliance HERNANDEZ_N 2/0 Routine Compliance
 
Site Inspection 09/30/2014 In Compliance SPARKS_JD_1 2/0 Routine Compliance
 
Site Inspection 08/31/2013 In Compliance SPARKS_JD_1 2/0 Routine Compliance
 
Site Inspection 10/19/2011 In Compliance SPARKS_JD_1 2/0 Routine Compliance
 
Record Document 09/13/2010 Satisfied SNYDERBURN_PJ_2 Non-Compliance
 
Site Inspection 08/30/2010 In Compliance SNYDERBURN_PJ_2 2/0 Routine Compliance
 
Site Inspection 12/27/2009 In Compliance SNYDERBURN_PJ_2 2/0 Non-Compliance
 
Site Inspection 05/01/2009 Major Out of Compliance SNYDERBURN_PJ_2 1/0 Installation
 
Letter 05/01/2009 Satisfied SNYDERBURN_PJ_2 Non-Compliance
 
 
 
No Open AOCs Found
 
 
Open Violations
 
Insp Date Vio # Significance Violation Text Corrective Action
01/26/2024 7119 Minor 3.17 Secondary containment for Mineral Acid Tank not certified by PE. Secondary containment shall be properly maintained. Any cracks, degradation, punctures, or other similar defects to the integrity of the secondary containment shall be repaired. Within 90 days of the inspection date, please ensure the DF's are properly sealed with approved epoxy that is compatible with sulfuric acid and sodium hydroxide.
 
 
 