Florida Department of Environmental Protection Bob Martinez Center 2600 Blair Stone Road Tallahassee, Florida 32399-2400 |
Storage Tanks & Contamination Monitoring Information |
|||||||||
Cover Page Report | |||||||||||
Report Run Date: 03/19/2025 Last Data Refresh: 03/18/2025 Report Generated from DOPPLER | |||||||||||
District | Northwest | Type | Retail Station | ||||||||
County | Escambia | Status | OPEN | ||||||||
ID | 9814471 | Latitude | 30° 25' 20.4158 | ||||||||
Name |
CIRCLE K#7746 501 E CERVANTES ST |
Longitude | 87° 12' 36.7408 | ||||||||
PENSACOLA, FL 32501 | LL Method | DPHO | |||||||||
Contact | STORE MGR | LL Status | REVIEWED | ||||||||
Phone | Status Date | 09/13/2023 | |||||||||
Account Owner Information | |||||||||||
Name | CIRCLE K STORES INC 25 W CEDAR ST STE M Pensacola, FL 32502 |
Effective Date | 02/19/2015 | ||||||||
Contact | IRA LEWIS/ SCOTT JANASHAK / DEBORAH BRATTON | ||||||||||
Phone | (850) 454-1070 | ||||||||||
ILEWIS@CIRCLEK.COM | |||||||||||
Placard # / Date | 697420 - 06/28/2024 | ||||||||||
Property Owner Information | |||||||||||
Name | CIRCLE K STORES INC 25 W CEDAR ST STE M Pensacola, FL 32502 |
Effective Date | 02/19/2015 | ||||||||
Contact | IRA LEWIS/ SCOTT JANASHAK / DEBORAH BRATTON | ||||||||||
Phone | (850) 454-1070 | ||||||||||
ILEWIS@CIRCLEK.COM | |||||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
1 | 20000 | Unleaded Gas (B) | 02/01/2015 | UNDERGROUND | In Service (U) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(C) Steel (I) Double wall (L) Compartmented (M) Spill containment bucket (N) Flow shut-Off (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(3) Electronic monitor pipe sumps (5) Electronic monitor dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (L) Automatic tank gauging - USTs |
|||||||||
Tank | Tank Size | Content | Installed | Placement | Status | ||||||
2 | 10000 | Vehicular Diesel (D) | 02/01/2015 | UNDERGROUND | In Service (U) | ||||||
Constructions | Pipings | Monitorings | |||||||||
(B) Internal lining (C) Steel (I) Double wall (N) Flow shut-Off (O) Tight fill |
(C) Fiberglass (F) Double wall (J) Pressurized piping system (K) Dispenser liners |
(3) Electronic monitor pipe sumps (5) Electronic monitor dispenser liners (F) Monitor dbl wall tank space (H) Mechanical line leak detector (L) Automatic tank gauging - USTs |
|||||||||
Insurance Documents | |||||||||||
FR Type | Effective Date | Expiration Date | Company Name | ||||||||
GUARANTEE | 04/28/2024 | 08/26/2025 | |||||||||
INSURANCE | 04/30/2023 | 08/28/2024 | |||||||||
GUARANTEE | 04/25/2021 | 08/27/2022 | |||||||||
INSURANCE | 12/01/2019 | 12/01/2020 | IRONSHORE SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 12/01/2019 | 12/01/2020 | NAVIGATORS SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 12/01/2018 | 12/01/2019 | IRONSHORE SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 12/01/2017 | 12/01/2018 | IRONSHORE SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 12/01/2016 | 12/01/2017 | IRONSHORE SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 12/01/2015 | 12/01/2016 | IRONSHORE SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 12/01/2014 | 12/01/2015 | IRONSHORE SPECIALTY INSURANCE CO | ||||||||
INSURANCE | 12/01/2013 | 12/01/2016 | IRONSHORE SPECIALTY INSURANCE CO | ||||||||
No Legacy Data Found | |||||||||||
Compliance Activity Information | |||||||||||
Activity Code |
Date Completed |
Results | Inspector | AST/UST Count |
Description | ||||||
Enforcement Referral | 06/26/2024 | Accepted | ELLIOTT_EV_1 | Enforcement | |||||||
Electronic Communication | 03/01/2024 | Satisfied | ELLIOTT_EV_1 | Routine Compliance | |||||||
Letter | 02/23/2024 | Satisfied | ELLIOTT_EV_1 | Compliance Assistance | |||||||
Site Inspection | 02/23/2024 | Major Out of Compliance | ELLIOTT_EV_1 | 0/2 | Routine Compliance | ||||||
Letter | 08/22/2022 | Satisfied | WILSON_ML_1 | Compliance Assistance | |||||||
Record Document | 08/09/2022 | Satisfied | GARTIN_D | Compliance Assistance | |||||||
Electronic Communication | 07/21/2022 | Satisfied | GARTIN_D | Compliance Assistance | |||||||
Record Document | 07/21/2022 | Satisfied | GARTIN_D | Compliance Assistance | |||||||
Letter | 06/08/2022 | Satisfied | WILSON_ML_1 | Compliance Assistance | |||||||
Electronic Communication | 05/24/2022 | Satisfied | GARTIN_D | Routine Compliance | |||||||
Site Inspection | 05/24/2022 | Major Out of Compliance | GARTIN_D | 0/2 | Routine Compliance | ||||||
Letter | 07/23/2020 | Satisfied | WILSON_ML_1 | Routine Compliance | |||||||
Issue Document | 07/23/2020 | Satisfied | WILSON_ML_1 | Routine Compliance | |||||||
Site Inspection | 07/21/2020 | In Compliance | BRAGG_SD_2 | 0/2 | Routine Compliance | ||||||
Letter | 07/30/2018 | Satisfied | WILSON_ML_1 | Routine Compliance | |||||||
Site Inspection | 07/30/2018 | In Compliance | BRAGG_SD_2 | 0/2 | Routine Compliance | ||||||
Issue Document | 07/30/2018 | Satisfied | WILSON_ML_1 | Routine Compliance | |||||||
Electronic Communication | 07/11/2018 | Satisfied | BRAGG_SD_2 | Routine Compliance | |||||||
Site Inspection | 04/05/2016 | In Compliance | PAYNE_CL_1 | 0/2 | Routine Compliance | ||||||
Phone Conversation | 03/15/2016 | Satisfied | PAYNE_CL_1 | Routine Compliance | |||||||
Site Inspection | 05/05/2015 | In Compliance | PAYNE_CL_1 | 0/2 | Installation | ||||||
Emergency Preparedness Information | 05/01/2015 | Satisfied | PAYNE_CL_1 | Installation | |||||||
No Open AOCs Found | |||||||||||
No Open Violations Found | |||||||||||
No Discharges Found |