Journal Report
Report Run Date: 04/30/2025        Last Data Refresh: 04/29/2025        Report Generated from DOPPLER
 
Facility ID: 9813006
Facility Name: HOMELAND SECURITY - ICE
 
08/19/2022 Attachment Trethewey, Mark B.
08/19/2022 Editable Letter Activity Trethewey, Mark B.
Activity Title: Compliance Assistance Offer Letter Activity Status: Closed
Events:
Event Type: Activity has been finished Date: 08/19/2022
Comment: Finished
Events:
Event Type: Document has been sent Date: 08/19/2022
Comment: Sent
Attachments:
Attachment Date: 08/19/2022 User: TRETHEWEY_MB_1
Description: CAO 2022-2023.018
View Attachment
08/19/2022 Phone Conversation Activity Trethewey, Mark B.
Call Type: Incoming Activity Status: Closed
Phone Number: (813) 682-6123 Activity Closed Date: 08/19/2022
Subject: Agreed to reschedule for 8/19/2022.
Events:
Event Type: Activity has been finished Date: 08/19/2022
Comment: Finished
08/19/2022 Site Inspection Activity Closed Trethewey, Mark B.
Activity Result: Major Out of Compliance Activity Status: Closed
On-Site Start Date: 08/19/2022
Activity Closed Date: 08/19/2022 Activity Closed By: TRETHEWEY_MB_1
Events:
Event Type: Activity has been finished Date: 08/19/2022
Comment: Finished
Comments:
Comment Date: 08/19/2022 User: TRETHEWEY_MB_1
Description: RECORDS: #9813006, 8/19/2022 Placard: Exempt per 62-762.401(2)(a)(1)(b) - Federally owned. Financial Responsibility: Government Agency- Exempt CoFR: N/A Release Detection: a. This Facility has the following release detection methods: 1. Veeder-Root TLS-350 console (EQ #197) with liquid level sensor in the interstice of the tank. A float sensor is located in the transition sump. Manual line leak detector for the primary piping and monthly visual inspections of the tank, fill and sump. b. Facility monthly release detection results: 1. The liquid status and alarm history tapes from 7/24/2019 to present were not available, provide Manatee County NRD with the next two months records for review. Note: A liquid status and Alarm History Report tape collected during this inspection is in file. 2. The monthly visual inspection records from 1/2018 to present were not provided. Immediately begin documenting visual inspections along with electronic history. Provide Manatee County NRD with next two months records for review. Tests: 1. The last annual operability test of the line leak detector provided was performed 1/4/2018 by Petroleum Maintenance & Services. Next test was due by 1/4/2019, 1/4/2020, 1/4/2021 and 1/4/2022, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. 2. The last annual operability test of the monitor and sensors provided was performed 1/4/2018 by Petroleum Maintenance & Services. Next test was due by 1/4/2019, 1/4/2020, 1/4/2021 and 1/4/2022, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. 3. The last annual operability test of the overfill alarm provided was performed 1/4/2018 by Petroleum Maintenance & Services. Next test was due by 1/4/2019, 1/4/2020, 1/4/2021 and 1/4/2022, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. 4. Integrity test of the sump provided was performed 1/4/2018 by Petroleum Maintenance & Services. Next test was due by 1/4/2021, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. PHYSICAL: Tank and piping: Tank, piping and equipment are in good condition. The overfill alarm is not operational, recommend battery replacement and visual monitoring during fill operations until replacement. All signage is faded and needs to be replaced. Transition Sump: The sump contains water greater than one inch. Immediately remove all water.
08/19/2022 Violation Open Trethewey, Mark B.
Significance: SNC-B Status: Open
Criteria ID: 7065
Rule: 62-762.601(1)(e), 62-762.602(1)(e)
08/19/2022 Violation Open Trethewey, Mark B.
Significance: Minor Status: Open
Criteria ID: 7072
Rule: 62-762.601(7), 62-762.602(7)
08/19/2022 Violation Open Trethewey, Mark B.
Significance: Minor Status: Open
Criteria ID: 7090
Rule: 62-762.701(4)(b), 62-762.701(4)(b)1, 62-762.701(4)(b)2, 62-762.702(4)(b), 62-762.702(4)(b)1, 62-762.702(4)(b)2
08/19/2022 Violation Open Trethewey, Mark B.
Significance: SNC-B Status: Open
Criteria ID: 7066
Rule: 62-762.601(1)(f), 62-762.601(1)(f)1, 62-762.602(1)(f), 62-762.602(1)(f)1
08/02/2022 Issue Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Cheryl Sellers Activity Closed Date: 08/19/2022
Events:
Event Type: Activity has been finished Date: 08/19/2022
Comment: Finished
Attachments:
Attachment Date: 08/19/2022 User: TRETHEWEY_MB_1
Description: 8/2/2022 Notification Letter
View Attachment
08/17/2020 Editable Letter Activity Brownlee, Sarah M
Activity Title: Warning Letter Activity Status: Closed
Events:
Event Type: Document has been sent Date: 08/14/2020
Comment: Sent
Events:
Event Type: Activity has been submitted for approval Date: 08/17/2020
Comment: Submitted for approval by: Sarah M Brownlee
Events:
Event Type: Activity has been finished Date: 08/31/2020
Comment: Finished
Events:
Event Type: Activity/Document has been approved Date: 08/18/2020
Comment: Approved by Jayme Brock: Approved
Attachments:
Attachment Date: 08/17/2020 User: BROWNLEE_S
Description: Warning Letter Email
View Attachment
06/11/2020 Enforcement Tracking Activity Brownlee, Sarah M
Activity Status: Open
06/03/2020 Electronic Communication Activity Trethewey, Mark B.
Activity Closed Date: 06/03/2020 Activity Status: Closed
Date: 06/03/2020
Recipient: Mark Trethewey
Sender: Bryan Zinober
Subject: Compliance
Message: Hi Mark. I have a new property manager (Liz) who is cc’d and I just want to make sure that we are in compliance for all the reports for the diesel tank at the GSA Bradenton ICE building in Bradenton. Thanks. Bryan Zinober
Events:
Event Type: Activity has been finished Date: 06/03/2020
Comment: Finished
06/03/2020 Electronic Communication Activity Trethewey, Mark B.
Activity Closed Date: 06/03/2020 Activity Status: Closed
Date: 06/03/2020
Recipient: Bryan Zinober
Sender: MarkTrethewey
Subject: Compliance
Message: Hi Bryan, As yet I haven’t received anything.
Events:
Event Type: Activity has been finished Date: 06/03/2020
Comment: Finished
06/03/2020 Enforcement Referral Activity Trethewey, Mark B.
Activity Result: Accepted Activity Status: Closed
Activity Closed Date: 06/11/2020
Events:
Event Type: Activity/Document was acknowledged on this date Date: 06/04/2020
Comment: Acknowledged and Assigned by Jayme Brock
Events:
Event Type: Activity has been assigned Date: 06/04/2020
Comment: Assigned to Sarah M Brownlee
Events:
Event Type: Activity has been submitted for approval Date: 06/03/2020
Comment: Submitted for approval by: Mark B. Trethewey: Referred for enforcement.
Events:
Event Type: Activity/Document was accepted on this date Date: 06/11/2020
Comment: Accepted by Sarah M Brownlee: .
Events:
Event Type: Activity has been finished Date: 06/11/2020
Comment: Finished
Comments:
Comment Date: 06/03/2020 User: TRETHEWEY_MB_1
Description: Referred for enforcement.
09/27/2019 Violation Open Trethewey, Mark B.
Significance: Minor Status: Open
Criteria ID: 5095
Rule: 62-762.601(1)(f), 62-762.601(1)(f)1.
09/27/2019 Editable Letter Activity Trethewey, Mark B.
Activity Title: Compliance Assistance Offer Letter Activity Status: Closed
Description: 2019-11-04-ANNUAL-DM-ic letter
Events:
Event Type: Activity has been finished Date: 09/27/2019
Comment: Finished
Events:
Event Type: Document has been sent Date: 09/27/2019
Comment: Sent
Attachments:
Attachment Date: 09/27/2019 User: TRETHEWEY_MB_1
Description: CAO 2019-2020.023
View Attachment
09/27/2019 Violation Open Trethewey, Mark B.
Significance: Minor Status: Open
Criteria ID: 5126
Rule: 62-762.701(4)(b), 62-762.701(4)(b)1., 62-762.701(4)(b)2.
09/27/2019 Violation Open Trethewey, Mark B.
Significance: SNC-B Status: Open
Criteria ID: 5094
Rule: 62-762.601(1)(d), 62-762.601(1)(e)
09/26/2019 Site Inspection Activity Closed Trethewey, Mark B.
Activity Result: Major Out of Compliance Activity Status: Closed
On-Site Start Date: 09/26/2019
Activity Closed Date: 09/27/2019 Activity Closed By: TRETHEWEY_MB_1
Events:
Event Type: Activity has been finished Date: 09/27/2019
Comment: Finished
Comments:
Comment Date: 09/27/2019 User: TRETHEWEY_MB_1
Description: RECORDS: #9813006, 9/26/2019 Placard: Exempt per 62-762.401(2)(a)(1)(b) - Federally owned. Financial Responsibility: Government Agency- Exempt CoFR: N/A Release Detection: a. This Facility has the following release detection methods: 1. Veeder-Root TLS-350 console (EQ #197) with liquid level sensor in the interstice of the tank. A float sensor is located in the transition sump. Manual line leak detector for the primary piping and monthly visual inspections of the tank, fill and sump. b. Facility monthly release detection results: 1. Reviewed the liquid status and alarm history tapes from 1/26/2018 to 7/24/2019. Note: A liquid status and Alarm History Report tape collected during this inspection is in file. 2. The monthly visual inspection records from 1/2018 to present were not provided. Immediately begin documenting visual inspections along with electronic history. Provide Manatee County PNRD with next three months release detection records. Tests: 1. The last annual operability test of the line leak detector was performed 12/28/2017 by Petroleum Maintenance & Services. Next test was due by 12/29/2018, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. 2. The annual operability test of the monitor and sensors was performed 12/28/2017 by Petroleum Maintenance & Services. Next test was due by 12/29/2018, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. 3. Breach of Integrity test of the sump was performed 1/4/2018 by Petroleum Maintenance & Services. Next test is due by 1/4/2021. PHYSICAL: Tank and piping: Tank, piping and equipment are in good condition. The overfill alarm is not operational, recommend battery replacement and visual monitoring during fill operations until replacement. Transition Sump: The sump contains water greater than one inch. Immediately remove all water.
09/19/2019 Issue Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Brian Zinober Activity Closed Date: 09/27/2019
Events:
Event Type: Activity has been finished Date: 09/27/2019
Comment: Finished
Attachments:
Attachment Date: 09/27/2019 User: TRETHEWEY_MB_1
Description: 9/19/2019 Notification Letter
View Attachment
03/13/2018 Electronic Communication Activity Brownlee, Sarah M
Activity Closed Date: 03/13/2018 Activity Status: Closed
Date: 03/13/2018
Recipient: Sarah Brownlee
Sender: Brian Zinober, Mark Trethewey
Subject: Email Chains
Message: See Attached
Events:
Event Type: Activity has been finished Date: 03/13/2018
Comment: Finished
03/12/2018 Issue Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Cheryl Sellers Activity Closed Date: 03/12/2018
Events:
Event Type: Activity has been finished Date: 03/12/2018
Comment: Finished
Attachments:
Attachment Date: 03/12/2018 User: TRETHEWEY_MB_1
Description: 3-12-2018 Return to Compliance Letter
View Attachment
03/12/2018 Record Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Cheryl Sellers Activity Closed Date: 03/12/2018
Events:
Event Type: Activity has been finished Date: 03/12/2018
Comment: Finished
Attachments:
Attachment Date: 03/12/2018 User: TRETHEWEY_MB_1
Description: Alarm History 1
View Attachment
Attachments:
Attachment Date: 03/12/2018 User: TRETHEWEY_MB_1
Description: Liquid Status - March 1 2018
View Attachment
01/10/2018 Record Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Jim Nuwer Activity Closed Date: 01/25/2018
Events:
Event Type: Activity has been finished Date: 01/25/2018
Comment: Finished
01/10/2018 Record Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Jim Nuwer Activity Closed Date: 01/24/2018
Events:
Event Type: Activity has been finished Date: 01/24/2018
Comment: Finished
Attachments:
Attachment Date: 01/24/2018 User: TRETHEWEY_MB_1
Description: 1-4-2018 tests
View Attachment
12/20/2017 Electronic Communication Activity Brownlee, Sarah M
Activity Closed Date: 12/20/2017 Activity Status: Closed
Date: 12/20/2017
Recipient: Re: Facility #9813006 Homeland Security open tank violations
Sender: Sarah Brownlee
Subject: Re: Facility #9813006 Homeland Security open tank violations
Message: See attached. This is a report of pervious email communication, attached wrong email.
Events:
Event Type: Activity has been finished Date: 12/20/2017
Comment: Finished
12/08/2017 Electronic Communication Activity Brownlee, Sarah M
Activity Closed Date: 12/20/2017 Activity Status: Closed
Date: 12/08/2017
Recipient: bzinober@dahlinvestments.com
Sender: Sarah Brownlee
Subject: Re: Facility #9813006 Homeland Security open tank violations
Message: See attached email chain
Events:
Event Type: Activity has been finished Date: 12/20/2017
Comment: Finished
12/06/2017 Phone Conversation Activity Brownlee, Sarah M
Call Type: Incoming Activity Status: Closed
Phone Number: (813) 658-3354 Activity Closed Date: 12/06/2017
Subject: Received call from Bryan. -Said he had delegated this out to someone, but dropped the ball on following through. -Thinks he has all the paperwork information, will find it and send it over ASAP. -Unsure about tank water removal, will check on it. -Assured he would CC me on all emails going forward.
Events:
Event Type: Activity has been finished Date: 12/06/2017
Comment: Finished
12/06/2017 Electronic Communication Activity Brownlee, Sarah M
Activity Closed Date: 12/06/2017 Activity Status: Closed
Date: 12/06/2017
Recipient: BRYAN.ZINOBER@FRANKLINSTREETFINANCIAL.COM
Sender: Sarah Brownlee
Subject: Email re:Open Violations
Message: See attached
Events:
Event Type: Activity has been finished Date: 12/06/2017
Comment: Finished
12/04/2017 Enforcement Tracking Activity Brownlee, Sarah M
Activity Status: Closed
Activity Result: Closed Without Enforcement Activity Closed Date: 03/13/2018
Events:
Event Type: Activity has been finished Date: 03/13/2018
Comment: Finished
11/30/2017 Enforcement Referral Activity Trethewey, Mark B.
Activity Result: Accepted Activity Status: Closed
Activity Closed Date: 12/04/2017
Events:
Event Type: Activity has been finished Date: 12/04/2017
Comment: Finished
Events:
Event Type: Activity/Document was accepted on this date Date: 12/04/2017
Comment: Accepted by Sarah M Brownlee: Acknowledged
Events:
Event Type: Activity has been submitted for approval Date: 11/30/2017
Comment: Submitted for approval by: Mark B. Trethewey: Have received no documents to resolve open violations.
Events:
Event Type: Activity/Document was acknowledged on this date Date: 12/04/2017
Comment: Acknowledged and Assigned by Laurel Culbreth
Events:
Event Type: Activity has been assigned Date: 12/04/2017
Comment: Assigned to Sarah M Brownlee
Comments:
Comment Date: 11/30/2017 User: TRETHEWEY_MB_1
Description: Have received no documents to resolve open violations.
Attachments:
Attachment Date: 01/09/2018 User: TRETHEWEY_MB_1
Description: Prop App Info
View Attachment
Attachments:
Attachment Date: 01/09/2018 User: TRETHEWEY_MB_1
Description: ER Memo 1-8-2018
View Attachment
Attachments:
Attachment Date: 01/09/2018 User: TRETHEWEY_MB_1
Description: 9813006 Site Map & Equipment Location
View Attachment
Attachments:
Attachment Date: 01/09/2018 User: TRETHEWEY_MB_1
Description: Corp info
View Attachment
11/30/2017 Phone Conversation Activity Trethewey, Mark B.
Call Type: Incoming Activity Status: Closed
Phone Number: (941) 742-5980 Activity Closed Date: 11/30/2017
Subject: Bryan returned call. Unaware of problems at Facility. Will address ASAP.
Events:
Event Type: Activity has been finished Date: 11/30/2017
Comment: Finished
11/30/2017 Electronic Communication Activity Trethewey, Mark B.
Activity Closed Date: 11/30/2017 Activity Status: Closed
Date: 11/30/2017
Recipient: Bryan Zinober
Sender: Mark Trethewey
Subject: Facility violations
Message: Good morning Bryan, We’ll need to address these violations. Thanks, Mark Trethewey Parks and Natural Resources Environmental Protection Division Senior Environmental Specialist (941)742-5980 ext. 1880 1112 Manatee Ave. W., 2nd Floor Bradenton, FL 34205
Events:
Event Type: Activity has been finished Date: 11/30/2017
Comment: Finished
11/30/2017 Electronic Communication Activity Trethewey, Mark B.
Activity Closed Date: 11/30/2017 Activity Status: Closed
Date: 11/30/2017
Recipient: Mark Trethewey
Sender: Bryan Zinober
Subject: Facility violations
Message: Mark – We should have everything to you by the end of next week. Sorry for the delay. Thanks, Bryan
Events:
Event Type: Activity has been finished Date: 11/30/2017
Comment: Finished
08/14/2017 Editable Letter Activity Trethewey, Mark B.
Activity Title: Compliance Assistance Offer Letter Activity Status: Closed
Events:
Event Type: Activity has been finished Date: 08/14/2017
Comment: Finished
Events:
Event Type: Document has been sent Date: 08/14/2017
Comment: Sent
Attachments:
Attachment Date: 08/14/2017 User: TRETHEWEY_MB_1
Description: CAO 2017-2018.006
View Attachment
08/11/2017 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 5140
Rule: 62-762.702(4)(b), 62-762.702(4)(b)1., 62-762.702(4)(b)2.
08/11/2017 Violation Closed Trethewey, Mark B.
Significance: SNC-B Status: Closed
Criteria ID: 5104
Rule: 62-762.602(1)(d), 62-762.602(1)(e)
08/11/2017 Violation Closed Trethewey, Mark B.
Significance: SNC-B Status: Closed
Criteria ID: 5097
Rule: 62-762.601(1)(g)
08/11/2017 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 5113
Rule: 62-762.602(7)
08/11/2017 Violation Closed Trethewey, Mark B.
Significance: SNC-B Status: Closed
Criteria ID: 5107
Rule: 62-762.602(1)(g)
08/03/2017 Site Inspection Activity Closed Trethewey, Mark B.
Activity Result: Major Out of Compliance Activity Status: Closed
On-Site Start Date: 08/03/2017
Activity Closed Date: 08/14/2017 Activity Closed By: TRETHEWEY_MB_1
Events:
Event Type: Activity has been finished Date: 08/14/2017
Comment: Finished
Comments:
Comment Date: 08/11/2017 User: TRETHEWEY_MB_1
Description: RECORDS: #9813006, 8/3/2017 Placard: Exempt per 62-762.401(2)(a)(1)(b) - Federally owned. Financial Responsibility: Government Agency- Exempt CoFR: N/A Release Detection: a. This Facility has the following release detection methods: 1. Veeder-Root TLS-350 console (EQ #197) with liquid level sensor in the interstice of the tank. A float sensor is located in the transition sump. Manual line leak detector for the primary piping and monthly visual inspections of the tank, fill and sump. b. Facility monthly release detection results: 1. The liquid status tapes from 8/2014 to present were not provided. This violation has not been resolved since last inspection. Immediately provide Manatee County PNRD with all required release detection records. Note: A liquid status and Alarm History Report tape collected during this inspection is in file. 2. The monthly visual inspection records from 8/2014 to present were not provided. This violation has not been resolved since last inspection. Immediately provide Manatee County PNRD with all required release detection records. Tests: 1. The annual operability test of the line leak detector was performed 9/9/2014 by Petroleum Maintenance & Services. Next tests were due by 9/9/2015 and 9/9/2016 results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. 2. The annual operability test of the monitor and sensors was performed 9/9/2014 by Petroleum Maintenance & Services. Next tests were due by 9/9/2015 and 9/9/2016 results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. PHYSICAL: Tank and piping: Tank, piping and equipment are in good condition. The overfill alarm is not operational, recommend battery replacement and visual monitoring during fill operations. Transition Sump: The sump contains water greater than one inch. Immediately remove all water.
Attachments:
Attachment Date: 08/11/2017 User: TRETHEWEY_MB_1
Description: TCI 8/3/2017 Transition water greater than an inch.
View Attachment
07/21/2017 Issue Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Bryan Zinober Activity Closed Date: 08/14/2017
Events:
Event Type: Activity has been finished Date: 08/14/2017
Comment: Finished
Attachments:
Attachment Date: 08/14/2017 User: TRETHEWEY_MB_1
Description: 7/21/2017 Notification Letter
View Attachment
10/16/2015 Editable Letter Activity Trethewey, Mark B.
Activity Title: 1st Non-Compliance Letter Activity Status: Closed
Events:
Event Type: Activity has been finished Date: 10/16/2015
Comment: Finished
Attachments:
Attachment Date: 10/16/2015 User: TRETHEWEY_MB_1
Description: NCL 2015-2016.007
View Attachment
10/09/2015 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 2132
Rule: 62-762.711(1)
10/09/2015 Site Inspection Activity Closed Trethewey, Mark B.
Activity Result: Minor Out of Compliance Activity Status: Closed
On-Site Start Date: 10/09/2015
Activity Closed Date: 10/16/2015 Activity Closed By: TRETHEWEY_MB_1
Events:
Event Type: Activity has been finished Date: 10/16/2015
Comment: Finished
Comments:
Comment Date: 10/16/2015 User: TRETHEWEY_MB_1
Description: RECORDS: #9813006, 10/9/2015 Placard: Exempt per 62-762.401(2)(a)(1)(b) - Federally owned. Financial Responsibility: Government Agency- Exempt CoFR: N/A RDRL: Not provided. Release Detection: a. This Facility has the following release detection methods: 1. Veeder-Root TLS-350 console (EQ #197) with liquid level sensor in the interstice of the tank. A float sensor is located in the transition sump. Manual line leak detector for the primary piping and monthly visual inspections of the tank, fill and sump. b. Facility monthly release detection results: 1. The liquid status tapes from 8/2014 to present were not provided. Note: A liquid status and Alarm History Report tape collected during this inspection is in file. 2. The monthly visual inspection records from 8/2014 to present were not provided. Tests: 1. The annual operability test of the line leak detector was performed 9/9/2014 by Petroleum Maintenance & Services. Next tests were due by 9/9/2015, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. 2. The annual operability test of the monitor and sensors was performed 9/9/2014 by Petroleum Maintenance & Services. Next tests were due by 9/9/2015, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. PHYSICAL: Tank and piping: Tank, piping and equipment are in good condition. The overfill alarm is currently operational. Transition Sump: The sump contains water under the piping, recommend removal and proper disposal at next inspection event.
10/09/2015 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 2122
Rule: 62-762.701(1)(c)3.
Comments: Facility must prove that all release detection devices, such as in line leak detectors, sump and liner sensors, etc. function properly. Sensing devices may be optical, vapor, float activated, discriminating, non discriminating, or tied into electrical circuits.
11/04/2014 Record Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Bryan Zenober Activity Closed Date: 11/04/2014
Events:
Event Type: Activity has been finished Date: 11/04/2014
Comment: Finished
08/28/2014 Editable Letter Activity Trethewey, Mark B.
Activity Title: 1st Non-Compliance Letter Activity Status: Closed
Description: AST testing doc
Events:
Event Type: Activity has been finished Date: 08/28/2014
Comment: Finished
Attachments:
Attachment Date: 08/28/2014 User: TRETHEWEY_MB_1
Description: NCL 2014-2015.004
View Attachment
08/26/2014 Site Inspection Activity Closed Trethewey, Mark B.
Activity Result: Minor Out of Compliance Activity Status: Closed
On-Site Start Date: 08/26/2014
Activity Closed Date: 08/28/2014 Activity Closed By: TRETHEWEY_MB_1
Events:
Event Type: Activity has been finished Date: 08/28/2014
Comment: Finished
Comments:
Comment Date: 08/28/2014 User: TRETHEWEY_MB_1
Description: RECORDS: #9813006, 8/26/2014 Placard: Exempt per 62-762.401(2)(a)(1)(b) - Federally owned. Financial Responsibility: Government Agency- Exempt Violations Cited at Compliance Inspection 4/8/2014: 1. Violation Text: Cannot detect a new release from any portion of the system. Rule: 62-762.601(1)(a)1. Significance Minor Explanation: Transition sump is full of PCW. Corrective Action: Immediately remove and properly dispose of all PCW. Corrective Action Taken: Yes. Re-inspection confirms that sump has been emptied, minor water from recent rain events remain. Recommend continued monitoring and removal of water at next maintenance event. 2. Violation Text: Not repaired component which has or could cause a discharge or release. Rule: 62-762.701(1)(a)1.d., 62-762.701(1)(a)1.c., 62-762.701(1)(a)1.b., 62-762.701(1)(a)1.a. Explanation: The transition sump cover has been removed. Sump is filled with PCW. Significance: Minor Corrective Action: Immediately replace the sump cover. Corrective Action Taken: Yes. Re-inspection confirms that the sump cover has been replaced. 3. Violation Text: Spill containment, dispenser liners and piping sumps not accessible; water and regulated substances not removed. Rule: 62-762.701(1)(c)1. Significance: Minor Explanation: Spill containment, dispenser liners and piping sumps accessible; water and regulated substances not removed. Transition sump is full of PCW. Corrective Action: Immediately remove and properly dispose of all PCW. Corrective Action Taken: Yes. Re-inspection confirms that sump has been emptied. 4. Violation Text: Release detection devices not tested annually. Rule: 62-762.701(1)(c)3. Significance Minor Explanation: The annual operability tests of the line leak detectors, monitor and sensors were due by1/18/2013 and 1/18/2014. Corrective Action: Immediately have the required tests performed and provide Manatee County PNRD with copies of the results Corrective Action Taken: NO. Test results have not been received by Manatee County PNRD. Review of Alarm History tape shows no changes or activity. Tape printout is the same as at inspection of 4/8/2014. Immediately have the required tests performed and provide Manatee County PNRD with copies of the results. NOTE: Previous release detection records violations have been resolved, one test violation remains open.
08/13/2014 Record Document Activity Trethewey, Mark B.
Activity Status: Closed
Contact Name: Bryan Zinober Activity Closed Date: 08/14/2014
Events:
Event Type: Activity has been finished Date: 08/14/2014
Comment: Finished
04/09/2014 Editable Letter Activity Trethewey, Mark B.
Activity Title: 1st Non-Compliance Letter Activity Status: Closed
Events:
Event Type: Activity has been finished Date: 04/09/2014
Comment: Finished
Attachments:
Attachment Date: 04/09/2014 User: TRETHEWEY_MB_1
Description: NCL 2013-2014.042
View Attachment
04/08/2014 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 2122
Rule: 62-762.701(1)(c)3.
Comments: Facility must prove that all release detection devices, such as in line leak detectors, sump and liner sensors, etc. function properly. Sensing devices may be optical, vapor, float activated, discriminating, non discriminating, or tied into electrical circuits.
04/08/2014 Site Inspection Activity Closed Trethewey, Mark B.
Activity Result: Major Out of Compliance Activity Status: Closed
On-Site Start Date: 04/08/2014
Activity Closed Date: 04/09/2014 Activity Closed By: TRETHEWEY_MB_1
Events:
Event Type: Activity has been finished Date: 04/09/2014
Comment: Finished
Comments:
Comment Date: 04/09/2014 User: TRETHEWEY_MB_1
Description: RECORDS: #9813006, 4/8/2014 Placard: Exempt per 62-762.401(2)(a)(1)(b) - Federally owned. Financial Responsibility: Government Agency- Exempt CoFR: N/A RDRL: Supplied at inspection. Release Detection: a. This Facility has the following release detection methods: 1. Veeder-Root TLS-350 console (EQ #197) with liquid level sensor in the interstice of the tank. A float sensor is located in the transition sump. Manual line leak detector for the primary piping and monthly visual inspections of the tank, fill and sump. b. Facility monthly release detection results: 1. The liquid status tapes from 1/18/2012 to present were not provided. Note: A liquid status and Alarm History Report tape collected during this inspection is in file. L2- Sump is in alarm. 2. The monthly visual inspection records from 1/18/2012 to present were not provided. Visual inspections are to include condition of tank, equipment, piping, transition sump and the interstitial status. Ensure that release detection is performed and documented at least once a month not exceeding 35 days apart. Generator unit is inspected along with the sub-base tank. Inspections do not include the remote 3000 gal. fuel tank. Provide Manatee County NRD with copies of the next three months release detection records and liquid status tapes for review. Tests: 1. The annual operability test of the line leak detector was due by 1/18/2013 and 1/18/2014, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. 2. The annual operability test of the monitor and sensors were due by 1/18/2013 and 1/18/2014, results were not provided. Immediately have the required test performed and provide Manatee County NRD with copies of the results. PHYSICAL: Tank and piping: Tank, piping and equipment are in good condition. The overfill alarm is not currently operational, battery needs to be replaced. Ensure that manual stick gauging is used until battery replacement. Transition Sump: The sump is full of rainwater. The sump cover has been removed. Immediately remove and properly dispose of PCW. Immediately replace the missing sump cover.
04/08/2014 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 2120
Rule: 62-762.701(1)(c)1.
Comments: Facility equipment shall be maintained to a degree to allow you access. Water in spill containment units, especially above the fill cap shall be removed. Water in any sumps and dispenser liners above the piping opening/penetration (invert) shall be removed. All regulated substance shall be removed from any of the specified system components. Regulated substances: sheen, free product, mixed product water. Petroleum contact water shall be disposed of in accordance with the Department Hazardous Waste Section's Ch. 62-740 F.A.C., "Petroleum Contact Water".
04/08/2014 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 2070
Rule: 62-762.601(1)(e)
Comments: The electronic monitoring unit is a system consisting of a sensor, wiring, and a panel. The sensor and the component that it monitors are exempt from the visual inspection process. However, the proper operation of the remainder of the electronic system must be verified on a monthly basis. One way to test is to activate the panel alarm switch. Depending on the system in place this test may check the alarm light, alarm horn, or the circuit continuity between the panel and the remote sensor. This test procedure must be documented by the facility, as required in rule 762.711(2). The remote verification feature meets this requirement, such as the Veeder-Root Simplicity system.
04/08/2014 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 2110
Rule: 62-762.701(1)(a)1.a., 62-762.701(1)(a)1.b., 62-762.701(1)(a)1.c., 62-762.701(1)(a)1.d.
04/08/2014 Violation Closed Trethewey, Mark B.
Significance: SNC-B Status: Closed
Criteria ID: 2069
Rule: 62-762.601(1)(d)
Comments: Mark this as out of compliance if any release detection method has not been monitored as required. Look for evidence that the release detection system is not being properly monitored. Examples include: blocked access to monitoring wells, buried or submerged sampling ports; corroded locks; or no dispenser keys. Be aware that manual tank gauging requires weekly sampling. Electronic line leak detectors may be wired into an ATG with a memory of test cycles. Facilities with static/periodic ATG systems are required to provide one passing test per product per month. This method has a minimum fuel capacity requirement. If there is a record keeping problem, see rule 62-762.711(2).
Comments:
Comment Date: 07/08/2014 User: CULBRETH_L
Description: Time extension until 8/8/2014 for Manatee County to work with the facility to resolve the violation.
04/08/2014 Violation Closed Trethewey, Mark B.
Significance: Minor Status: Closed
Criteria ID: 2065
Rule: 62-762.601(1)(a)1.
Comments: Mark this as out of compliance if the release detection method is not able to register or detect a new release. If you feel that the release detection system has lost its ability to detect a new release, document why in the inspection report. Examples include: a. An automatic tank gauge system already in alarm mode will not be able to detect a new release; b. sumps with water/product may impair detection abilities; c. monitoring wells at contaminated sites may also have impaired ability to detect new releases. See .641(2)(c)2. for further guidance on using contaminated monitoring wells for release detection.
01/20/2012 Attachment Trethewey, Mark B.
01/20/2012 Attachment Trethewey, Mark B.
01/20/2012 Site Inspection Activity Closed Trethewey, Mark B.
Activity Result: In Compliance Activity Status: Closed
On-Site Start Date: 01/18/2012
Activity Closed Date: 01/20/2012 Activity Closed By: TRETHEWEY_MB_1
Events:
Event Type: Activity has been finished Date: 01/20/2012
Comment: Finished
Comments:
Comment Date: 01/20/2012 User: TRETHEWEY_MB_1
Description: Facility Name: Homeland Security ICE Installation Inspection Field Notes SITE VISITS: 11/22/2011 ¿ Mark Trethewey on-site at 1:10 PM. Contractor: JMP Solutions Inc. 12065 Metro Parkway Ft. Myers, FL 33966 Jeff (813) 875-8997 OPW Flexworks underground pipe (EQ-649) has been installed; pressure introduced yesterday and currently holding primary and secondary as introduced. Hydro-test of transition sump to be performed at final inspection. 01/18/2012 ¿ Mark Trethewey on-site at 8:45 AM. One (1), 3,000 gallon Modern Welding-Fireguard (EQ-274) double-wall steel aboveground petroleum storage tank for generator diesel had been installed. The tank was set on a concrete pad and was equipped with a Morrison electric solenoid valve, Morrison #918 overfill gauge w/alarm (EQ-527), and Morrison overfill flow shut-off (EQ-356). The Fireguard tank has a Morison spill bucket #515 (EQ-535). Interstitial monitoring will be electronic via Veeder-Root TLS 350 (EQ-197) (L1 sensor). Piping is aboveground to a FlexWorks transition sump; piping runs through an underground chase and feeds a 150 gallon generator base tank. Fuel is supplied by a red jacket STP w/ LLD, transition sump is monitored electronically with the Veeder-Root monitor (L-2 sensor). All signage was properly applied. The transition sump was hydro-tested beginning yesterday afternoon and was holding water at time of inspection. A Storage Tank Registration Form was provided to FLDEP, placard not to be sent, Facility is exempt from fees per 62-762.401 (2)(b). A Release Detection Response Level Form and Monthly Visual Inspection Form were provided to the Facility with the inspection report. RELEASE DETECTION, as of 1/18/2012: a. Electronic interstitial and sump monitoring. b. Monthly visual inspections which includes visual monitoring of the double-walled tank, transition sump, fills and spill containments, piping condition and surrounding area. FINANCIAL RESPONSIBILITY: Government Agency- Exempt