SIC Code Gen Stat Total HW Disposal Data Type Date Org Contact Org Code
3443 - Manufacturing - Fabricated Plate Work (Boiler Shops)  3 - Very Small Quantity Generator 79  V - Verification By On-Site Visit  05-JUN-23  Cory Seay  37 - Leon 
Full-Time Employees Facility Updated Date
14  05-JUN-23 
Comments:
Comment Date Comment
20-APR-21  Annual Msgp Facility Inspection Conducted. There Is No Mechanical Work Perfomed At This Facility. Facility Works On Truck Tanks And Trailers. There Were Several Drums Of Diesel Ful That Were Not Labeled And Did Have Secondary Containment. Advised To Lbael Drums And Provide Secondary Containment. 
19-APR-22  Annual Msgp Facility Inspection Conducted. No Significant Issues Observed. Educational Brochures Reviewed. 
05-JUN-23  Annaul Msgp Facility Inspection Conducted With John Hubbs. Tanker Trailer Repair Is Conducted At Facility. There Are Three Other Businesses On Proiperty (Vause Mechanical, Ding King - Paint & Body, Westfall Framing). There Were Three Palstic Drums Outside That Didn'T Have Secondary Containment. One Of The Drums Was Starting To Develop Cracks. Cory Seay & Gerren Watson Spoke With Mr. Hubbs About The Drums. Mr. Hubbs Stated The Drums Belonged To Vause Mechanical And Hel Will Let Them Know To Provide Containment, Shelter And Label. Educational Brochures Distributed. 
23-MAR-16  Facility Inspection Conducted, Brochures Handed Out. Has Well And City Water. 
14-FEB-18  Reminded Manager To Continue To Label And Provide Secondary Containment For Waste Materials. I Reviewed And Distributed Educational Brochures. 
14-FEB-19  Annual Msgp Facility Inspection. Business Is No Longer Mckenzie Tank Lines, Now Its Terminal Service Company. 
02-MAR-20  Annual Msgp Facility Inspection. No Issues Observed. 
Waste Info
Waste Type Storage Method Disposal Method Mo. (Units) Max Mo. (Lbs) Lbs/
Year
Disposal Location Ques Storage Ques Disposal RCRA Hazardous
UKEH - Absorbents Contaminated W/Oil  C3 - 10-39 Gallon Container  EC - Commercial Laundry (Rags)  0 ( POUNDS )  Off-Site 
 Comments: Burned As Fuel For Heaters Or Picked Up. 
LDEB - Fluorescent Lamps/Devices  OG - Other Good  EE - Universal Waste  1.83 ( 4 FT FLUORESCENT TUBES )  12  Off-Site 
 Comments: Dispose 22('4) On 03/09/2023 
BDEB - Lead-Acid Batteries  OG - Other Good  ER - Exempt Recycle (Battery, Etc)  .83 ( UNITS )  32  378  Off-Site 
 Comments: Picks Up 5 To 10 Batteries/Year 
NPIA - Mineral Spirits-Parts Cleaner  OP - Parts Washer  HH - Shipped For Hw Rcra Treatment  9.33 ( GALLONS )  61  79  Off-Site 
 Comments: Burned As Fuel For Heaters 
UWNE - Oily Waste Water  TB - Tanks Below Ground  EW - Industrial Wastewater Treatment  6375 ( GALLONS )  53168  638010  Off-Site 
 Comments: Wash Water From Truck Wash And Oily Water. Facility Hauls Wash Water To Jackson To Be Disposed Of At Liquid Environmental Solutions. 
UREH - Rags With Oil  C1 - 0-9 Gallon Container  EC - Commercial Laundry (Rags)  400 ( UNITS )  44  528  Off-Site 
 Comments: Cintas Comes By Facility Once Per Week And Picks Up 100 Rags. 
MBHR - Sludges With Heavy Metals  C5 - 40 Or More Gallon Container  SL - Solid Waste Lined Landfill (Dump)  0 ( DRUMS (55 GALLONS) )  Off-Site 
 Comments: Picked Up With Oily Water & Wash Water 
UPEO - Used Oils & Other Lubricants  C5 - 40 Or More Gallon Container  BU - Used Oil Burner At This Facility  2 ( DRUMS (55 GALLONS) )  838  10058  On-Site 
 Comments: Facility Rcycles Used Oil As Fuel For Heaters In Shops. 
Activity Info
Activity Type Description Activity Date Return To Compliance Date
DX  Other materials(specify in comments)  04-AUG-09   
MH  DEP Summary of HW Regulations  04-AUG-09   
MM  Fluorescent lamps/Mercury Containing Devices  04-AUG-09   
MU  Summary of Used Oil / Used Oil Filter Regs  04-AUG-09   
 

Signature: ________________________________________
Date: ________________________________________