Facility Info | |||||||||
Facility ID | County | Status | EPA ID | Other ID | Old Fac. ID | Follow Up | |||
---|---|---|---|---|---|---|---|---|---|
83067 | Polk | A - Active - Waste Generator | FLD984176032 | UNINCORP | 5318050 | N - None Needed | |||
Facility Name | Mailing Address | Location Address | Contact | Title | Phone | E-mail Address | |||
Ssi Lubricants Llc | 5131 Recker Hwy Winter Haven, FL 33880 |
5131 Recker Hwy Winter Haven, 33880 |
Steve Ervin | Business Development Manager | (863) 287-1684 | ||||
SIC Code | Gen Stat | Total HW Disposal | Data Type | Date | Org Contact | Org Code | |||
5171 - Wholesale Trade - Petroleum Bulk Stations And Terminals | N - NOT A HAZARDOUS WASTE GENERATOR | 0 | V - Verification By On-Site Visit | 04-JUN-09 | A Stermer | 53 - Polk | |||
Full-Time Employees | Facility Updated Date | ||||||||
15 | 26-APR-13 | ||||||||
Comments: | |||||||||
Comment Date | Comment | ||||||||
26-FEB-02 | Petroleum Jobber-Was Robert Hart | ||||||||
04-JUN-09 | An Inspection Was Performed With Shannon Camp, Fdep After Investigating The Set Of Storage Facilities Directly Behind The Facility'S Tank Farm. It Appears They Have Had Some Type Of Used Oil Discharge Outside Their Secondary Containment Area For The Fuel Tanks. They Transport Fuel And Lubes After Packaging Containers Of Product From Bulk Drums (Oil, Gas & Diesel). Sometimes When They Get Drums Back From Customers, There Is Some Used Oil Left Behind. Richie'S Truck Repair Does The Maintenance Of Their Vehicles. The Ditch Was Recently Redone (Resodded And Added Rocks). There Are 21 Tanks Of Oil Inside That Are 4,000 Gallons Each. Fdep Is Handling All Follow-Up On This Facility--A Stermer |
Waste Info | |||||||||
Waste Type | Storage Method | Disposal Method | Mo. (Units) | Max Mo. (Lbs) | Lbs/ Year |
Disposal Location | Ques Storage | Ques Disposal | RCRA Hazardous |
---|---|---|---|---|---|---|---|---|---|
UKEH - Absorbents Contaminated W/Oil | C5 - 40 Or More Gallon Container | EU - Shipped For Used Oil Recycling | 1 ( DRUMS (55 GALLONS) ) | 350 | 2100 | Off-Site | N | Y | N |
Comments: 6/4/09--From Drivers--Amts Are Estimated--Als | |||||||||
LDEB - Fluorescent Lamps/Devices | OG - Other Good | AD - Awaiting Disposal - Planned | 2 ( 4 FT FLUORESCENT TUBES ) | 1 | 7 | On-Site | N | N | N |
UPEO - Used Oils & Other Lubricants | TA - Tanks Above Ground | EU - Shipped For Used Oil Recycling | 700 ( GALLONS ) | 5334 | 18288 | Off-Site | N | N | N |
Comments: 6/4/09--Some Oily Waste Comes From A Tank Clean-Out--Als |
Activity Info | |||||||||
Activity Type | Description | Activity Date | Return To Compliance Date | ||||||
---|---|---|---|---|---|---|---|---|---|
DX | Other materials(specify in comments) | 04-JUN-09 | |||||||
OC | FAILURE TO LABEL USED OIL CONTAINERS 279.22 | 04-JUN-09 | |||||||
OE | OILCONTAINER W/ NO 2ND CONTAINMENT 62-710.401(6) | 04-JUN-09 | |||||||
OR | FAILURE TO RESPOND TO OIL RELEASE 62-710.401(3)(A) | 04-JUN-09 | |||||||