Facility Detailed List Report

Number of Facilities = 1
Facility Info
Facility ID County Status EPA ID Other ID Old Fac. ID Follow Up
28030  Duval  A - Active - Waste Generator  FLD984228858  NHBOR  1603038  N - None Needed 
Facility Name Mailing Address Location Address Contact Title Phone E-mail Address
B & K Diesel Electric Service Inc  Po Box 28898
Jacksonville, FL  32226 
11640 Camden Rd, 1 
Jacksonville, 32218
Dianne Sowell  Estimator  (904) 751-3512  
SIC Code Gen Stat Total HW Disposal Data Type Date Org Contact Org Code
7538 - Services - General Automotive Repair Shops  N - NOT A HAZARDOUS WASTE GENERATOR V - Verification By On-Site Visit  05-OCT-15  M. Cain  16 - Duval 
Full-Time Employees Facility Updated Date
08-JAN-16 
Comments:
Comment Date Comment
05-OCT-15  B & K Diesel Electric Service, Inc. Specializes In Selling, Repairing, And Installing Generator Sets And Controls. They Have Been At This Address For 25 Years. The Facility Consists Of Offices, A Supply Storage Warehouse, And Two Bays. There Was No Floor Drain Noted. Used Oil, Used Oil Filters, Used Antifreeze, And Spent Lead Acid Batteries Are Generated Off-Site At The Customers' Address. Sometimes The Wastes Are Collected In Different Labeled Five-Gallon Containers And Transported Back To The Main Office By Truck. There Are Three Trucks At This Facility And They Are Serviced By Local Repair Shops. The Used Oil Is Stored In Two Labeled 500-Gallon Single-Walled Tanks. The Tanks Are Located Inside The Building And The Building Is Being Used As Secondary Containment. Used Oil Filters Were Uncrushed And Stored In Two Labeled 55-Gallon Drums Located In The Bay Area. Used Antifreeze Is Stored In A 500-Gallon Single-Walled Tank And The Tank Was Not Labeled. A Stencil Was Provided To The Estimator, Ms. Dianne Sowell, To Label The Used Antifreeze Tank Located In The Bay Area. Spent Lead-Acid Batteries Were Stored Inside The Bay On A Pallet. There Were Not Three Years Of Disposal Receipts For Used Oil, Used Oil Filters, Used Antifreeze, And Spent Lead-Acid Batteries Available. Ms. Sowell Was Advised That Waste Management Records For Regulated Wastes Must Be Kept On File For A Minimum Of Three Years. There Is A Sink Style Parts Washer At This Facility That Is Leased From Crystal Clean. The Parts Washer Is Used To Clean Tools. The Solvent Used In The Parts Washer Is A High Flash, Non-Hazardous Petroleum Naphtha That Is Being Managed By Crystal Clean As A Non-Dot/Rcra Regulated Parts Cleaning Solvent.Used Shop Rags Are Stored In An Unlabeled 55-Gallon Drum And Are Cleaned By Unifirst Uniform Company. Ms. Sowell Stated That Used Shop Rags Are Only Contaminated With Used Oil. No Aerosols Are Used And No Painting Is Conducted By The Business. 
05-OCT-15  (Continued 2) Spent Fluorescent Lamps Have Not Been Generated In Three Years. Ms. Sowell Was Provided With Information On Storage And Disposal Of Spent Fluorescents And Was Given The Managing Spent Fluorescent And High Intensity Discharge (Hid) Lamps Handout. The Jacksonville Emergency Management Plan Requirement Was Mailed To Ms. Sowell With A Handout Explaining The City Ordinance. Based On Information Or Documentation Provided By The Facility, On 10/5/2015 The Inspector Advised Ms. Dianne Sowell That B & K Diesel Electric Service, Inc. Was Classified As A Generator Of Non-Hazardous, But Otherwise Regulated, Waste In Accordance With City Ordinance Code Chapter 123. 
Waste Info
Waste Type Storage Method Disposal Method Mo. (Units) Max Mo. (Lbs) Lbs/
Year
Disposal Location Ques Storage Ques Disposal RCRA Hazardous
AMEO - Antifreeze (Hw Except When Recycled)  TA - Tanks Above Ground  ER - Exempt Recycle (Battery, Etc)  9 ( GALLONS )  75  834  Off-Site 
 Comments: Amounts Were Estimated By The Facility Contact. Only One Disposal Receipt Was Available. The Tank Was Not Labeled. 
BDEB - Lead-Acid Batteries  GF - Piled On The Floor Or Table  ER - Exempt Recycle (Battery, Etc)  15 ( UNITS )  570  6840  Off-Site 
 Comments: Amounts Were Estimated By The Facility Contact. Only One Disposal Receipt Was Available. 
NPIA - Mineral Spirits-Parts Cleaner  OP - Parts Washer  NH - Non-Haz Management (Tested/Confirmed)  20 ( GALLONS )  132  526  Off-Site 
 Comments: The Solvent Used In The Parts Washer Is Non-Hazardous Petroleum Naphtha. 
UREH - Rags With Oil  C5 - 40 Or More Gallon Container  EC - Commercial Laundry (Rags)  400 ( UNITS )  44  528  Off-Site 
 Comments: Amounts Were Estimated By The Facility Contact. 
UUNO - Uncrushed Oil Filters  C5 - 40 Or More Gallon Container  EU - Shipped For Used Oil Recycling  59 ( POUNDS )  59  700  Off-Site 
 Comments: Only One Disposal Receipt Was Available. 
UPEO - Used Oils & Other Lubricants  TA - Tanks Above Ground  EU - Shipped For Used Oil Recycling  140 ( GALLONS )  1067  11125  Off-Site 
 Comments: Only Nine Months Of Disposal Receipts Were Available. 
Activity Info
Activity Type Description Activity Date Return To Compliance Date
DX  Other materials(specify in comments)     
MF  Antifreeze for Recycling / Antifreeze Facts     
MM  Fluorescent lamps/Mercury Containing Devices     
MU  Summary of Used Oil / Used Oil Filter Regs     
 

Signature: ________________________________________
Date: ________________________________________