Florida Department of Environmental Protection

Hazardous Waste Facility Compliance History


Activity History Listing


Activity History for:

EPAID: FLD980847271, Safety-Kleen Systems Inc


Note: ETA links to Enforcement Tracking Activity
Date Done Activity Type Activity Comments ETA Link
10/18/1988 Compliance Evaluation Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
01/30/1989 Financial Record Review Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
07/06/1989 Legacy Site Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
08/14/1989 Financial Record Review Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
03/06/1990 Legacy Site Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
04/20/1990 Legacy Site Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
05/14/1990 Warning Letter Issued Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
05/30/1990 Financial Record Review Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
06/19/1990 Legacy Site Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
06/19/1990 Legacy Site Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
09/26/1990 Warning Letter Issued Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
10/10/1990 Other Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
10/23/1990 Compliance Schedule Evaluation Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
05/03/1991 Legacy Site Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
05/03/1991 Warning Letter Issued Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
06/12/1991 Financial Record Review Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
07/18/1991 Consent Order Executed Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
08/26/1991 Corrective Action Activities Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
10/28/1991 Compliance Evaluation Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
10/12/1992 Legacy Site Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
10/12/1992 Warning Letter Issued Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
11/10/1993 Legacy Site Inspection Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
11/11/1993 Compliance Evaluation Inspection
11/19/1993 Warning Letter Issued
12/01/1993 Enforcement Meeting Counter Offer Due On Penalties. Counter Offer Due On Penalties.
12/15/1993 Financial Record Review Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
01/06/1994 Draft Consent Order Issued Sfco Sent To Scott Fore. Response Due Jan 6. Sfco Sent To Scott Fore. Response Due Jan 6.
01/20/1994 Short Form Consent Order Executed $1,900 Penalty Collected. $1,900 Penalty Collected.
01/20/1994 Case Closed By District
09/12/1994 Financial Record Review Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
11/10/1994 Legacy Site Inspection
12/21/1994 Warning Letter Issued Warning Letter Due Warning Letter Due
01/18/1995 Enforcement Meeting Sk To Provide Documentation Of Return To Compliance | Documentation Provided February 1, 1995. Sk To Provide Documentation Of Return To Compliance | Documentation Provided February 1, 1995.
02/10/1995 Short Form Consent Order Issued
03/16/1995 Short Form Consent Order Executed Cash Penalty Received. Cash Penalty Received.
03/16/1995 Case Closed By District
05/24/1995 Financial Record Review Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
11/29/1995 Legacy Site Inspection
02/02/1996 Warning Letter Issued
03/21/1996 Return To Compliance Letter
03/21/1996 Compliance W/O Formal Enforcement Action Facility Had Documented Return To Compliance. Facility Had Documented Return To Compliance.
03/27/1996 Return To Compliance Letter Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
06/18/1996 Financial Record Review Downloaded From Rcris On 18-Oct-96 Downloaded From Rcris On 18-Oct-96
10/15/1996 Financial Record Review
10/31/1996 Legacy Site Inspection Conducted Compliance Inspection Conducted Compliance Inspection
11/19/1996 Compliance Monitoring Evaluation (Groundwater)
12/02/1996 Financial Record Review
12/13/1996 Warning Letter Issued Response To Wl Due Response To Wl Due
12/26/1996 Compliance W/O Formal Enforcement Action
02/06/1997 Project Closed Letter
06/25/1997 Financial Record Review
09/15/1997 Financial Record Review
01/22/1998 Financial Record Review
06/25/1998 Legacy Site Inspection
08/10/1998 Financial Record Review
12/30/1998 Warning Letter Issued
01/13/1999 Financial Record Review
01/22/1999 Enforcement Meeting Response Due 2 Feb 98. Response Due 2 Feb 98.
02/05/1999 Short Form Consent Order Issued Suspense For Response 20feb99. Suspense For Response 20feb99.
03/01/1999 Short Form Consent Order Executed
03/01/1999 Case Closed By District
03/01/1999 Return To Compliance Letter
06/17/1999 Legacy Site Inspection
08/27/1999 Warning Letter Issued
08/27/1999 Significant Non-Complier - Yes
09/28/1999 Enforcement Meeting Consent Order Being Drafted. Consent Order Being Drafted.
09/28/1999 Significant Non-Complier - No All Violations Corrected, Co Being Executed. All Violations Corrected, Co Being Executed.
10/15/1999 Short Form Consent Order Issued Awaiting Response From Sk. S:15days. Awaiting Response From Sk. S:15days.
11/23/1999 Permit Condition Or Consent Order/Response Due Signed Consent Order Received From Sk. Signed Consent Order Received From Sk.
11/29/1999 Permit Condition Or Consent Order/Response Due Settlement Check Received. Settlement Check Received.
12/01/1999 Short Form Consent Order Executed
12/01/1999 Return To Compliance From Formal Enforcement
12/01/1999 Project Closed Letter
12/01/1999 Case Closed By District
01/11/2000 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
01/11/2000 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
01/11/2000 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
04/20/2000 Legacy Site Inspection
04/20/2000 Informal Verbal Enforcement
04/24/2000 Compliance W/O Formal Enforcement Action
04/24/2000 Project Closed Letter
02/01/2001 Financial Record Review Certificate Of Insurance | Edgar Echevarria - Reviewer Certificate Of Insurance | Edgar Echevarria - Reviewer
02/01/2001 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria - Reviewer Certificate Of Liability Insurance | Edgar Echevarria - Reviewer
03/13/2001 Legacy Site Inspection
03/13/2001 Enforcement Project Initiated
05/01/2001 Warning Letter Issued
05/24/2001 Enforcement Meeting
08/23/2001 Enforcement Meeting
08/30/2001 Telephone Conversation Revised Penalty Revised Penalty
09/21/2001 Short Form Consent Order Issued
10/15/2001 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
11/02/2001 Short Form Consent Order Executed Penalty Paid. Case Closed. Penalty Paid. Case Closed.
11/02/2001 Return To Compliance From Formal Enforcement
11/05/2001 Return To Compliance Letter
11/05/2001 Project Closed Letter
11/05/2001 Case Closed By District
01/10/2002 Legacy Site Inspection
01/10/2002 Enforcement Project Initiated
01/25/2002 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
02/25/2002 Warning Letter Issued
03/21/2002 Enforcement Meeting
03/27/2002 File Review Resolved Or Provided Schedule To Resolve Noncompliance Issues Resolved Or Provided Schedule To Resolve Noncompliance Issues
05/28/2002 Return To Compliance Letter
06/18/2002 Short Form Consent Order Issued
08/28/2002 Short Form Consent Order Executed
08/30/2002 Project Closed Letter Signed Co And Check Rcvd. - - Dept. Executed Co Signed Co And Check Rcvd. - - Dept. Executed Co
08/30/2002 Case Closed By District Executed Co Sent Out Executed Co Sent Out
09/01/2002 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
09/01/2002 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
11/17/2002 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
01/25/2003 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
01/25/2003 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
05/29/2003 Legacy Site Inspection Facility Is To Do Annual Tank Inspection Per Subpart Cc Facility Is To Do Annual Tank Inspection Per Subpart Cc
05/29/2003 Informal Verbal Enforcement
07/14/2003 File Review
07/14/2003 Compliance W/O Formal Enforcement Action
08/12/2003 Project Closed Letter
08/12/2003 Case Closed By District
10/15/2003 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
10/15/2003 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
02/03/2004 Compliance Evaluation Inspection
02/04/2004 Legacy Site Inspection Inspection Report Being Drafted. Inspection Report Being Drafted.
02/04/2004 Informal Verbal Enforcement Violation Corrected And Returned To Compliance During Compliance Inspection Violation Corrected And Returned To Compliance During Compliance Inspection
03/01/2004 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
03/01/2004 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
03/29/2004 Return To Compliance Letter
03/29/2004 Compliance W/O Formal Enforcement Action
03/29/2004 Project Closed Letter
03/29/2004 Case Closed By District
05/28/2004 Warning Letter Issued Suspense 06/15/04. Suspense 06/15/04.
07/02/2004 Telephone Conversation Enforcement Meeting Scheduled For 08/02/04. Enforcement Meeting Scheduled For 08/02/04.
08/02/2004 Enforcement Meeting Sk Response Due Department Nlt August 23, 2004. Accept Department Offer Or Nov. Sk Response Due Department Nlt August 23, 2004. Accept Department Offer Or Nov.
08/21/2004 Submittal Received By Department Response To Sk Reply Being Drafted. No Change In Penalty. Response To Sk Reply Being Drafted. No Change In Penalty.
10/29/2004 Letter Final Offer Letter Sent To Sk. Response Due 11/10/04. Final Offer Letter Sent To Sk. Response Due 11/10/04.
11/15/2004 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
11/15/2004 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
11/16/2004 Submittal Received By Department Sk Did Not Accept Final Offer. Case Being Referred To Ogc For Resolution. Sk Did Not Accept Final Offer. Case Being Referred To Ogc For Resolution.
11/23/2004 Case Referred To Ogc Case Referred To Ogc For Resolution Of Halogen Screening Requirement. Case Referred To Ogc For Resolution Of Halogen Screening Requirement.
11/29/2004 File Review
11/29/2004 Case Closed By District
11/29/2004 File Review
11/29/2004 Case Closed By District
02/10/2005 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
02/10/2005 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
03/14/2005 Legacy Site Inspection Need To Return To Review Manifest And Transporter Records Need To Return To Review Manifest And Transporter Records
03/23/2005 Project Closed Letter Facility Corrected Violations And Returned To Compliance Facility Corrected Violations And Returned To Compliance
03/23/2005 Case Closed By District
09/01/2005 Financial Record Review Certificate Of Liability Insurance Certificate Of Liability Insurance
11/09/2005 Interdepartmental Memo Request Case Be Returned To District From Ogc For Final Disposition. Request Case Be Returned To District From Ogc For Final Disposition.
01/19/2006 Legacy Site Inspection A Second Site Visit Is Necessary To Check Records A Second Site Visit Is Necessary To Check Records
01/23/2006 File Review
01/25/2006 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
01/25/2006 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
02/02/2006 Compliance W/O Formal Enforcement Action
02/02/2006 Project Closed Letter
02/02/2006 Case Closed By District
02/15/2007 Meeting Met With Branch General Manager To Verify Halogen Screening On All Pickups. In Compliance With Screening Requiements. Met With Branch General Manager To Verify Halogen Screening On All Pickups. In Compliance With Screening Requiements.
02/15/2007 Case Closed By District Facility In Compliance With Screening Requirement. No Formal Enforcement Will Be Pursued. Facility In Compliance With Screening Requirement. No Formal Enforcement Will Be Pursued.
02/15/2007 Compliance W/O Formal Enforcement Action
07/20/2007 Legacy Site Inspection Report Drafted; Awaiting Approval Report Drafted; Awaiting Approval
07/20/2007 Informal Verbal Enforcement
07/20/2007 Compliance W/O Formal Enforcement Action
11/01/2007 Return To Compliance Letter
11/01/2007 Project Closed Letter
11/01/2007 Case Closed By District
01/25/2008 Financial Record Review Certificate Of Insurance | Edgar Echevarria-Reviewer Certificate Of Insurance | Edgar Echevarria-Reviewer
01/25/2008 Financial Record Review Certificate Of Liability Insurance | Edgar Echevarria-Reviewer Certificate Of Liability Insurance | Edgar Echevarria-Reviewer
08/28/2008 Site Inspection Permitting; TSD Facility Safety-Kleen Systems, Inc., (Sk) Was Inspected To Determine Its Compliance With State And Federal Hazardous Waste Regulations. Sk Is A Permitted Hazardous Waste Storage And Recycling Facility And Also Leases Out Various Parts Cleaning Machines To Its Customers. Core Business Lines Include Parts Cleaners, Immersion Cleaners And Paint Gun Cleaners, As Well As Aqueous Cleaners (Brake And Parts Cleaners). In Addition, Sk Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps And Spent Antifreeze (Ethylene Glycol). The Company Is Also A Hazardous Waste Transfer Facility That Receives Wastes From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Wastes Received Or Generated At The Facility Are Stored In Containers Or Tanks. | The Facility Has Not Changed Since The Previous Inspection. Other Than Materials Handling, The Major Process Ongoing At The Facility Is Drum Cleaning, Which Utilizes An Enclosed, Automated Spritzer System. Used Solvent Is Brought Back To The Facility From Designated Customers And Used To Clean Drums. After Cleaning, The Spent Solvent Is Pumped To The Facility'S Hazardous Waste Storage Tank. The Cleaning Process, As Well As The Process Of Emptying Drums Of Customers' Spent Solvent, Generates Hazardous Waste Solids/Debris And Sludge, Which Are Accumulated In 55-Gallon Drums Located At The Facility'S Wet Dumpsters. When Full, The Drums Are Moved Into Storage And Managed With The Rest Of The Stored Wastes. Except For Qa Samples, Which Are Stored In Flammables Cabinets And Retained For Only 90 Days, Used Oil Transported By Sk Is Not Brought Back To The Facility, But Is Taken To The Trans-Flo Tampa Transfer Facility And Loaded Onto A Rail Car For Shipment To Another Sk Facility. Ethylene Glycol Is Stored On Site And Shipped For Recycling To Georgia Petroleum. Additional Details About The Facility May Be Found In Permit #34744-Ho-005 And The Associated Permit Application. | Based On The Observations Made During The Inspections, Sk Was Found To Have Two Paperwork Violations. There Were Also Two Permit Condition Deficiencies Noted. These Violations Have Been Corrected. | Submitting For Approval | Submitted For Approval By Honey, Kelly | Submitted For Approval By Honey, Kelly
11/21/2008 Informal Verbal Enforcement Finished-11/21/2008
03/20/2009 Financial Record Reviewed for FINANCIAL RECORD-01/01/2009 ; Finished-03/20/2009
03/20/2009 Financial Record Reviewed for FINANCIAL RECORD-01/01/2009 ; Finished-03/20/2009
09/30/2009 Site Inspection Routine; Used Oil-Other - Routine; LQG (>1000 kg/month) - Routine; TSD Facility - Routine; Hazardous Waste Transfer Facility Safety-Kleen Systems, Inc., (Sk) Was Inspected To Determine Its Compliance With State And Federal Hazardous Waste Regulations. Sk Is A Permitted Hazardous Waste Storage And Recycling Facility And Also Sells And Leases Out Various Parts Cleaning Machines To Its Customers. Core Business Lines Include Parts Cleaners, Immersion Cleaners And Paint Gun Cleaners, As Well As Aqueous Cleaners (Brake And Parts Cleaners). In Addition, Sk Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps And Spent Antifreeze (Ethylene Glycol). The Company Is Also A Hazardous Waste Transfer Facility That Receives Wastes From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Wastes Received Or Generated At The Facility Are Stored In Containers Or Tanks. The Inspectors Were Accompanied By Mr. John Walters, Branch General Manager, Who Is Also The Designated Emergency Coordinator. | The Facility Has Not Changed Since The Previous Inspection. Other Than Materials Handling, The Major Process Ongoing At The Facility Is Drum Cleaning, Which Utilizes An Enclosed, Automated Spritzer System. Used Solvent Is Brought Back To The Facility From Designated Customers And Used To Clean Drums. After Cleaning, The Spent Solvent Is Pumped To The Facility'S Hazardous Waste Storage Tank. The Cleaning Process, As Well As The Process Of Emptying Drums Of Customers' Spent Solvent, Generates Hazardous Waste Solids/Debris And Sludge, Which Are Accumulated In A 55-Gallon Drum Located At The Facility'S Wet Dumpster. When Full, The Drum Is Moved Into Storage And Managed With The Rest Of The Stored Wastes. Additional Details About The Facility May Be Found In Permit #34744-Ho-005 And The Associated Permit Application. The Current Permit Expires On November 23, 2011. Note That A Complete Application For The Renewal Of The Permit Must Be Submitted To The Department No Later Than May 27, 2011. Except For Qa Samples And The Occasional Drum, Used Oil Transported By Sk Is Not Brought Back To The Facility, But Is Taken To The Trans-Flo Tampa Transfer Facility And Loaded Onto A Rail Car For Shipment To Another Sk Facility In Illinois. At The Time Of The Inspection, There Was A 22,000-Gallon Frac-Tank In The Yard. The Tank Was Not In Use, But Mr. Walters Indicated That Sk Was Considering Using It To Store Used Oil Brought Back To The Facility. Mr. Walters Was Directed To Contact Mr. Anthony Tripp At (850) 245-8766 Prior To Using The Tank, Since Storing Customers' Used Oil In This Tank Is Not Addressed In The Facility'S Existing Permit. Used Oil Filters Are Stored In Large Containers On The East Side Of The Return/Fill Area Where There Is No Secondary Containment. At The Time Of The Inspection, There Were No Used Oil Filters On Site, However, Examination Of The Contents Of Some Of Twelve 'Empty' Containers Showed That At Least Three Of Them Had Measurable Used Oil In The Bottoms. Not All Of The Containers Could Be Opened Due To Their Arrangement, However. This Was Discussed During The Inspection, And Staff Were Directed To Begin Checking The Rest Of The Containers And Move Those With Used Oil Into The Contained Area, Or Get Them Pumped Out. After The Inspection, Mr. Walters Stated That Half The Containers Were Immediately Pumped Out, And The Other Half Were Moved Into The Containment Area Until They Could Be Pumped Out. Used Ethylene Glycol Is Stored On Site And Was Being Shipped For Recycling To Georgia Petroleum. Since The Inspection, However, Sk Is Considering Shipping The Material For Processing With Used Oils At A Facility In Ocala That Was Recently Acquired By Safety-Kleen. Section 7.1.7 Of The Permit Application Specifies That This Material Will Be Recycled. This Proposed Practice Is Therefore Not Allowed Under The Existing Permit. Sk Has Obtained A Sample Of The Used Anti-Freeze To Determine If It Is Hazardous Or Not. The Department Has Requested A Copy Of The Analytical Report For Review And Evaluation Befo
11/10/2009 Warning Letter Sent for WARNING LETTER-11/10/2009 ; Finished-11/19/2009 19758
12/09/2009 Phone Conversation Finished-12/09/2009 19758
01/11/2010 Short Form Consent Order Issued for SHORT FORM CONSENT ORDER-12/04/2009 ; Response Due for SHORT FORM CONSENT ORDER-01/03/2010 ; Executed for SHORT FORM CONSENT ORDER-01/11/2010 ; Finished-01/11/2010 19758
01/11/2010 Penalty Received for PENALTY-01/08/2010 ; Finished-01/11/2010 19758
01/13/2010 Letter Sent for LETTER-01/13/2010 ; Finished-01/22/2010 19758
01/22/2010 Enforcement Tracking Finished-01/22/2010
03/30/2010 Financial Record Reviewed for FINANCIAL RECORD-11/17/2009 ; Finished-03/30/2010
03/30/2010 Financial Record Reviewed for FINANCIAL RECORD-09/01/2009 ; Finished-03/30/2010
08/20/2010 Site Inspection Routine; TSD Facility - Routine; Used Oil Transporter - Routine; Universal Waste Transporter - Routine; Hazardous Waste Transfer Facility Safety-Kleen Systems, Inc., (Safety Kleen) Was Inspected To Determine Its Compliance With State And Federal Hazardous Waste Regulations. Sk Is A Permitted Hazardous Waste Storage And Recycling Facility And Also Sells And Leases Out Various Parts Cleaning Machines To Its Customers. Core Business Lines Include Parts Cleaners, Immersion Cleaners And Paint Gun Cleaners, As Well As Aqueous Cleaners (Brake And Parts Cleaners). In Addition, Safety Kleen Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps And Spent Antifreeze (Ethylene Glycol). The Company Is Also A Hazardous Waste Transfer Facility That Receives Wastes From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Wastes Received Or Generated At The Facility Are Stored In Containers Or Tanks. The Inspectors Were Accompanied By Mr. John Walters, Branch General Manager, Who Is Also The Designated Emergency Coordinator. | The Facility Has Not Changed Since The Previous Inspection. Other Than Materials Handling, The Major Process Ongoing At The Facility Is Drum Cleaning, Which Utilizes An Enclosed, Automated Spritzer System. Used Solvent Is Brought Back To The Facility From Designated Customers And Used To Clean Drums. After Cleaning, The Spent Solvent Is Pumped To The Facility'S Hazardous Waste Storage Tank. The Cleaning Process, As Well As The Process Of Emptying Drums Of Customers' Spent Solvent, Generates Hazardous Waste Solids/Debris And Sludge, Which Are Accumulated In A 55-Gallon Drum Located At The Facility'S Wet Dumpster. When Full, The Drum Is Moved Into Storage And Managed With The Rest Of The Stored Wastes. Additional Details About The Facility May Be Found In Permit #34744-Ho-005 And The Associated Permit Application. The Current Permit Expires On November 23, 2011. A Complete Application For The Renewal Of The Permit Must Be Submitted To The Department No Later Than May 27, 2011. Except For Qa Samples And The Occasional Drum, Used Oil Transported By Sk Is Not Brought Back To The Facility, But Is Taken To The Trans-Flo Tampa Transfer Facility And Loaded Onto A Rail Car For Shipment To Another Sk Facility In Illinois. Used Oil Filters May Be Stored In Large Containers On The East Side, North Of The Return/Fill Area Where There Is No Secondary Containment. At The Time Of The Inspection, There Were No Used Oil Filters On Site, However, Examination Of The Contents Of Some Of Containers Showed That At Least Four Of Them Had Measurable Used Oil Of At Least 2-Inches Inside. Staff Were Directed To Move Those With Used Oil Into The Contained Area, Or Get Them Pumped Out. This Was Noted In The Previous Inspection Report. Also In The Return/Fill Area, The Coating Of The Containment Floor Was Observed To Be Peeling Up And Was In Need Of Recoating. One Of The Loading Dock Sumps On The East Side Of The Facility Was Also In Need Of Recoating. This Has Been Scheduled. Two Small Spills Of Used Oil Were Observed On The Ground Outside The Return/Fill Area On The West Side. Since The Previous Inspection, Safety Kleen Has Gotten Rid Of Its Tanker Of Used Ethylene Glycol, Which Is No Longer Stored On Site. According To Documentation Received After The Inspection, Safety Kleen Picks Up Used Only Ethylene Glycol That Has Been Comingled With Used Oil. The Used Oil Is Processed At Safety Kleen'S East Chicago, Illinois, Facility By Heating And Then Condensing The Light Ends Which Are Collected And Shipped For Further Ethylene Glycol Recovery By Unnamed Third Parties. Inspection Of The Storage Areas Of The Facility Indicates That The Facility Was Within The Allowable Volume Storage Limits, As Well As The Allowable Time Limits. All The Waste Containers Observed Were Labeled And Dated, Although There Were Inconsistencies Regarding Where The Dates On Some Of The Wastes Were Marked. The Department Is Concerned That The Inconsistencies Could Lead To Transfer Wastes Being Stored For More Than 10 Days. Additionally,
10/04/2010 Warning Letter Sent for WARNING LETTER-10/04/2010 ; Finished-10/05/2010 27533
11/09/2010 Meeting Finished-11/09/2010 27533
12/10/2010 Short Form Consent Order Drafted for SHORT FORM CONSENT ORDER-11/18/2010 ; Sent for SHORT FORM CONSENT ORDER-11/22/2010 ; Approved for SHORT FORM CONSENT ORDER-11/22/2010 ; Finished-12/10/2010 ; Executed for SHORT FORM CONSENT ORDER-12/10/2010 27533
12/10/2010 Letter Sent for LETTER-12/10/2010 ; Finished-12/14/2010 27533
12/14/2010 Enforcement Tracking Finished-12/14/2010
03/03/2011 Financial Record Reviewed for FINANCIAL RECORD-11/17/2010 ; Finished-03/03/2011
03/03/2011 Financial Record Reviewed for FINANCIAL RECORD-11/17/2010 ; Finished-03/03/2011 This One Needs To Be Deleted Entered It Twice.
03/03/2011 Financial Record Reviewed for FINANCIAL RECORD-09/01/2010 ; Finished-03/03/2011
08/09/2011 Site Inspection Routine; TSD Facility Safety Kleen Systems Was Inspected For Compliance With The Conditions Of Its Operating Permit, 34744-Ho-005, Issued July 3, 2007. The Facility Has Submitted An Application To Renew The Permit, Which Is Currently Under Review. Jon Walters Explained Operations During The Inspection, Along With Jeff Curtis And Other Staff. The Permit Authorizes Safety Kleen To Store Hazardous Waste In Containers And A Tank System, And The Facility Also Acts As A Hazardous Waste Transfer Facility. The Facility Has A Septic System For Sanitary Wastes And Utility Sinks, And Also Has A Potable Water Well Operated Under A Department Of Health Permit, Although The Well Is Not Typically Used For Drinking Water. The Information On The Septic System Was Not Included In The Facility'S Renewal Application. | Safety Kleen'S Core Business Has Been To Service Parts Washers For Small Quantity Hazardous Waste Generators In The Automotive And Printing Industries. As Part Of That Service, The Company Accepts Other Used Automotive Fluids And Oily Wastes. The Company Has Also Serviced Dry Cleaners, And Accepts Dry Cleaning Solvents For Storage. The Company Manages Most Other Hazardous Wastes As Transfer Waste, But Branch Employees Provides Brokerage Services To Customers Within Branch Territories. The Local Customer Service Representatives Work With Staff At The Permitted Disposal Facilities To Profile Waste Streams For Both Hazardous Waste Program And Usdot Hazardous Materials Compliance. According To Mr. Walters, The Company Has Almost Completely Phased Out Their Low Flash Point 105 Solvent, And Use High Flash Point Solvent Almost Exclusively. Now, All Parts Washing Solvent Is Combined Into A Single Tank Prior To Shipment To A Recycling Center. This Includes Any 105 Solvent That Might Be Encountered From Washers That Have Not Been Serviced For A While. The Combined Solvent Is Shipped By Tank Trailer As D001, D018, D039, D040 Waste To Safety Kleen In Lexington, Sc. The Shipping Records And Land Disposal Restriction Notices For This Material Were In Compliance. The Branch Has Changed The Tanks Program Registration For Its Out-Of-Service Hazardous Waste Storage Tank To Used Oil, But It Is Currently Empty. Used Oil Is Still Being Off Loaded Directly Into A Rail Car At The Trans Flo Terminal. Outgoing Used Oil Records Confirm That Oil Is Not Stored More Than 35 Days At The Terminal; Several Shipments Occur Per Month. Used Oil Filters Are Shipped To Safety Kleen In Ocala For Further Management. Outgoing Manifests And Shipping Papers Were Reviewed And Found To Be In Order. The Containment Around The Tank System Was Clean, And The Tanks Were In Good Condition. However One Strap Supporting The Piping From The Collection Sump To The Tank Had Come Loose From The Concrete Wall Of The Building. The Tank Inspection Records Did Not List The Piping As A Separate Item Needing Inspection For Structural Integrity In Addition To Signs Of Leakage. Tank System Inspection Procedures Were Discussed With Responsible Staff, And Corrective Action Is Being Taken. Tank System Components Subject To Regulation Under 40 Cfr 264 Subparts Bb And Cc Were Inspected If Accessible. Gratings Covering Some Equipment Were Pulled To Confirm That The Components Were Tagged In Accordance With The Permit. It Was Noted That The Flanged Manway Into The Hazardous Waste Tank Was Not Included In The List Of Subpart Bb Regulated Components In The Permit. Mr. Curtis Said That This Had Been Noted And Was Being Corrected In The Renewal Application. The Facility'S Subpart Bb/Cc Inspection Logs Include A Note That "Valves 1, 2, 4, 24, 25 And 32 Are No Longer In Service Effective 4/10/95." However The Inspection Records Indicated Valves 2, 4 And 24 Were Being Inspected And Were In Good Condition. The Department Requested That The Inspection Forms Being Used Be Updated To Reflect The Current Equipment List. Other Inspection Records Were Being Kept, But Not All Of Them Included A Spa
09/14/2011 Warning Letter Drafted for WARNING LETTER-09/06/2011 ; Finished-09/14/2011 ; Sent for WARNING LETTER-09/14/2011 154528
10/13/2011 Meeting Finished-10/13/2011 154528
11/01/2011 Short Form Consent Order Drafted for SHORT FORM CONSENT ORDER-10/19/2011 ; Issued for SHORT FORM CONSENT ORDER-10/21/2011 ; Finished-11/01/2011 ; Executed for SHORT FORM CONSENT ORDER-11/01/2011 154528
11/08/2011 Penalty Received for PENALTY-11/07/2011 ; Finished-11/08/2011 154528
11/10/2011 Enforcement Tracking Finished-11/10/2011
11/10/2011 Project Closed Letter Finished-11/10/2011 ; Sent for PROJECT CLOSED LETTER-11/10/2011 154528
12/01/2011 Groundwater Record Reviewed for GROUNDWATER RECORD-11/09/2011 ; Finished-12/01/2011
01/31/2012 Groundwater Record Reviewed for GROUNDWATER RECORD-01/04/2012 ; Finished-01/31/2012
03/02/2012 Financial Record Reviewed for FINANCIAL RECORD-11/17/2011 ; Finished-03/02/2012
03/02/2012 Financial Record Reviewed for FINANCIAL RECORD-09/01/2011 ; Finished-03/02/2012
07/17/2012 Site Inspection Routine; TSD Facility Safety Kleen'S Hazardous Waste Storage Facility Was Inspected July 17, 2012 In Conjunction With A Monitoring Well Installation Event. A Follow Up Record Review Was Conducted July 25, 2012. William "Tony" Hill And Jeff Curtis Represented The Facility During The Inspection. The Facility'S Operating Permit Was Renewed On February 21, 2012. Facility Operations Are Essentially The Same As During Previous Inspections, Except That A Tank Trailer Is Being Used For Transfer Of Oily Waste Water Collected Under The Company'S Vacuum Truck Service. The Tanker Is Provided With A Pop Up Secondary Containment. Use Of The Tank Trailer Is Discussed Further Below. | At The Time Of The Inspection, The Container Storage Areas Were Almost At Capacity Due To Several Large Shipments Of Material That Had Been Accepted For Transfer. All The Containers Were Closed, Properly Labeled And Provided With Adequate Aisle Space. Facility Employees Have Improved Their Waste Acceptance Procedures And Are Ensuring That Containers Are Free From Residue On The Exterior. The Hazardous Waste And Used Oil Storage Tanks And Piping Were In Good Condition. No Issues With The Supports Or With Equipment Tags Required Under 40 Cfr Subparts Aa, Bb And Cc Were Observed. The Dumpster Areas Were All Clean And Free From Residue. Spill Response Equipment Was Adequate And In Place. The Facility Has Removed The Shop Sink That Was Previously An Area Of Concern, And Is In The Process Of Ensuring That Discharges To The Facility Septic System Are Not A Source Of Contamination Requiring Remedial Action. Inspections Are Logged Daily In Accordance With The Facility'S Permit, Except For Non Operating Days Like Weekends. Waste Acceptance And Disposal Records Were On Site And Available For Inspection. Files Had Been Moved Because The Facility Was In The Process Of Updating Its Record Storage Room, But The Moved Files Were Well Organized. Records Were Also Avaiblable Electronically. The Facility Contingency Plan Was Posted And Up To Date. Training Records, Including Job Titles And Position Descriptions Were Available And Up To Date. Safety Kleen Waste Acceptance Procedures Were Discussed With Particular Regard To The Facility'S Vacuum Service For Non Hazardous Waste Waters. The Facility'S Waste Analysis Plan Requires Different Pre-Qualification Checks For Higher Risk Customers And Industrial Users Than For Routine Automotive Shops. Industrial Users Are Supposed To Provide Specific Information On The Process Generating The Waste Water, Along With A Sample For Analysis Before Safety Kleen Will Accept The Waste. The Wastes Collected By This Service Center Are Not Treated At A Safety Kleen Facility. Aqua Clean Environmental Services In Lakeland Accepted Most Of These Wastes For Treatment Until A Recent Temporary Facility Closure. Typically, Safety Kleen Would Off Load Their Vehicles At Aqua Clean. Currently, The Wastes Are Being Consolidated Into The Tank Trailer Discussed In The Introduction. The Trailer Is Owned By Liquid Environmental Solutions, Fld981928484, And Is Transferred To The Company'S Jacksonville Facility Every Few Days. An Empty Trailer Is Left In Its Place. Mr. Curtis Has Said That They Are Working On A Better Solution For This Material, As He Is Concerned That The Pop Up Containment May Become Worn Or Damaged With Continued Use. Waste Profiles For Specific Customers In This Program Were Reviewed With Mr. Curtis. In Most Cases, The Process Information Indicated The Material Was Used Coolant From Machine Shop Operations. However In Some Cases The Process Information Section Did Not Actually Describe The Process Generating The Waste. Waste From Elite Cnc Machining Was Described As "Dip Tank Rinse Water" Without A Process Description That Would Enable A Centralized Waste Water Treatment Facility To Determine If The Water Water Was Subcategory A, B Or C Waste. Profile #40445919 For Dart Container Indicated That The Waste Was "Waste Water" From
07/30/2012 Electronic Communication Finished-07/30/2012
03/04/2013 Groundwater Record Reviewed for GROUNDWATER RECORD-02/12/2013 ; Finished-03/04/2013
04/01/2013 Financial Record Reviewed for FINANCIAL RECORD-11/17/2012 ; Finished-04/01/2013
04/01/2013 Financial Record Reviewed for FINANCIAL RECORD-09/01/2012 ; Finished-04/01/2013
04/09/2013 Site Inspection Routine; Transporter - Routine; Used Oil-Other - Routine; LQG (>1000 kg/month) - Routine; TSD Facility Safety Kleen'S Hazardous Waste Storage Facility Was Inspected On April 9, 2013 To Determine The Facility'S Compliance With State And Federal Hazardous Waste Rules And Regulations, As Well As Compliance With The Facility'S Permit. Mr. William "Tony" Hill Assisted The Inspectors During The Inspection, And Mr. Jeff Curtis Provided Additional Assistance With Paperwork Following The On Site Inspection. The Facility Operations Have Not Changed Since The Previous Inspection, With The Exception That Oily Water Is Now Stored In The Tank Farm And The Pop Up Containment Has Been Removed. Safety Kleen Has Approved The Expense For Connecting To The Sanitary Sewer, However Was Still On A Septic Tank At The Time Of The Inspection. | At The Time Of The Inspection The Waste Storage Areas Were Well Organized And Housekeeping Was Being Maintained. The Hazardous Waste And Used Oil Storage Tanks And Piping Were In Good Condition. No Issues Were Noted With The Supports Or With Equipment Tags Required Under 40 Cfr 264 Subparts Aa, Bb And Cc. The Dumpster Areas Were All Clean And Free From Residue. There Were No Residues Observed On Drums Or Leaking Containers. Daily Inspections Are Being Conducted And Recorded As Required In The Facility'S Permit. Waste Has Been Moving Trough The Facility With In Appropriate Time Frames And There Was No Waste That Had Exceeded Holding Times Noted During The Inspection. Spill Response Equipment Was Adequate And Available. Waste That Is Generated On Site Is Collected And Managed In The Return And Fill Area. All Branch Generated Wastes Were Properly Closed, Labeled, And Inspected.The Property Is Fenced And Access Is Secured From Unauthorized Entry. Waste Acceptance And Disposal Records Were On Site And Available For Inspection. The Facility Contingency Plan Was Last Updated On January 9, 2013. Employee Position Descriptions And Training Records Are Up To Date. Safety Kleen'S Waste Minimization Plan Submitted For Review And The Most Recent Annual Waste Minimization Certification Was Done On February 27, 2013. Safety Kleen'S Renewed The Financial Assurance On November 17, 2012 And A Detail Cost Closure Estimate Plan Was Submitted For Review. | Safety Kleen Appeared To Be In Compliance With The Facility'S Permit, And State And Federal Hazardous Waste Regulations Applicable To Treatment Storage And Disposal Facilities At The Time Of The Inspection. | Safety Kleen Corrections Made | Safety Kleen | Safety Kleen Corrections Made
06/05/2013 Groundwater Record Reviewed for GROUNDWATER RECORD-05/15/2013 ; Finished-06/05/2013
10/02/2013 Groundwater Record Reviewed for GROUNDWATER RECORD-09/23/2013 ; Finished-10/02/2013
12/04/2013 Groundwater Record Reviewed for GROUNDWATER RECORD-11/20/2013 ; Finished-12/04/2013
04/01/2014 Financial Record Reviewed for FINANCIAL RECORD-11/13/2013 ; Finished-04/01/2014
04/01/2014 Financial Record Reviewed for FINANCIAL RECORD-09/01/2013 ; Finished-04/01/2014
05/01/2014 Groundwater Record Reviewed for GROUNDWATER RECORD-04/07/2014 ; Finished-05/01/2014
07/31/2014 Groundwater Record Reviewed for GROUNDWATER RECORD-07/02/2014 ; Finished-07/31/2014
10/01/2014 Groundwater Record Reviewed for GROUNDWATER RECORD-09/03/2014 ; Finished-10/01/2014
10/01/2014 Groundwater Record Reviewed for GROUNDWATER RECORD-09/12/2014 ; Finished-10/01/2014
04/01/2015 Financial Record Reviewed for FINANCIAL RECORD-11/17/2014 ; Finished-04/01/2015
04/01/2015 Financial Record Reviewed for FINANCIAL RECORD-11/01/2014 ; Finished-04/01/2015
08/25/2015 Site Inspection Routine; TSD Facility Safety-Kleen Systems, Inc., (Sk) Was Inspected On August 25, 2015, To Determine The Facility’S Compliance With State And Federal Hazardous Waste Regulations. The Department Most Recently Conducted A Hazardous Waste Inspection At This Facility In April 2013, And Has Inspected The Facility Many Times In The Past. The Inspectors Were Accompanied During The Inspection By Steve Gugino, Branch General Manager, And Chris Abel, Lead Material Handler. | Sk Is A Permitted Hazardous Waste Storage And Recycling Facility. The Facility Also Sells And Leases Out Various Parts Cleaning Machines To Its Customers. Core Business Lines Include Parts Cleaners, Immersion Cleaners And Paint Gun Cleaners, As Well As Aqueous Cleaners (Brake And Parts Cleaners). In Addition, Sk Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps And Spent Antifreeze (Ethylene Glycol). The Company Is Also A Hazardous Waste Transfer Facility That Receives Wastes From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Wastes Received Or Generated At The Facility Are Stored In Containers Or Tanks. The Facility Has Not Changed Operations Since The Previous Inspection. However, The Facility’S On-Site Septic System Was Taken Off-Line On 4/22/14, And The Wastewater Is Now Discharged To The City Of Tampa Publicly Owned Treatment Works (Potw). Other Than Material Handling, The Major Process Taking Place At The Facility Is Drum Cleaning. The Return And Fill Area, Located Between The North And South Buildings, Is Where Drivers Pick Up The Clean Solvents In The Morning For Customer Delivery And, In The Evening, Drop Off Spent Solvent Picked Up From The Customers That Day. Parts Washer Solvent From Customers Participating In Sk’S Continued Use Program (Cup) Is Used To Clean Returned Drums At The Sk Facility, And As Such, Is Still A Viable “Product” When Picked Up From The Customer. Cup Solvent Is Placed Into A Dedicated 200-Gallon “Continuous Use” Vat Which Is Piped To One Of Two Drum Washers/Wet Dumpsters Where It Is Spritzed Onto Brushes During The Drum Cleaning Process. Debris Generated From The Dumping And Washing Of Drums In The Dumpsters Is Placed In 55-Gallon Satellite Containers. At The Time Of The Inspection, There Was One Satellite Container Which Was Closed And Labeled As Hazardous Waste. The Secondary Containment In This Area Appeared To Be Clean, Dry And Intact. After Cleaning Of The Drums, The Spent Solvent Is Pumped To The Facility’S Hazardous Waste Storage Tank, Which Is Located In A Tank Farm Within Secondary Containment. There Are Three Tanks Located Within The Tank Farm Area: A Clean 150 Mineral Spirits Tank, A Used Oil Tank, And A Dirty Parts Washer Solvent (Hazardous Waste) Tank. All Three Tanks Appear To Be In Good Working Condition And All Were Properly Labeled. The Tank Farm Is Covered To Minimize Rain Water In The Secondary Containment Area. No Liquid Was Observed Within The Secondary Containment Area At The Time Of The Inspection. Examination Of The North And South Storage Areas Indicates The Waste At The Facility Was Within The Allowable Volume Storage Limits, And All Transfer Wastes Were Stored Within The 10 Day Limit. A Leaking Drum Was Observed In The South Storage Building (Non-Flammable Room) Within The 10 Day Transfer Waste Area. Standing Liquid Was Observed Within The Trench Area, Located Next To The Overhead Door On The West Side. According To Chris Abel The Liquid Was Rain Water Getting Into The Trench. Facility Personnel Over Packed The Leaking Drum During The Inspection, And Removed The Rain Water From The Trench The Same Day. A Leaking Drum Was Observed In The South Storage Building (Flammable Room) Within The 10 Day Transfer Waste Area. The Leaking Drum Was Over Packed During The Inspection. Additionally, The Inspectors Observed Four Drums (Labeled Ecopower 15w40) Located On A Secondary Containment Pallet And A 5-Gallon Container Of Unknown Liquid St
12/02/2015 Issue Non-Compliance Letter Compliance Assistance Offer Written for Issue Non-Compliance Letter-11/02/2015 ; Finished-12/02/2015
02/29/2016 Financial Record Reviewed for FINANCIAL RECORD-11/17/2015 ; Finished-02/29/2016
02/29/2016 Financial Record Reviewed for FINANCIAL RECORD-11/01/2015 ; Finished-02/29/2016
03/07/2017 Financial Record Reviewed-11/17/2016 ; Finished-03/07/2017
03/07/2017 Financial Record Reviewed-11/01/2016 ; Finished-03/07/2017
04/19/2017 Site Inspection Routine; TSD Facility Safety-Kleen Systems, Inc., (Sk) Was Inspected On April 19, 2017, To Determine The Facility’S Compliance With State And Federal Hazardous Waste Regulations. The Department Last Conducted A Hazardous Waste Inspection Of This Facility In August 2015, And Has Inspected The Facility Many Times In The Past. The Inspectors Were Accompanied During The Inspection By Steve Gugino, Branch General Manager, And Chris Abel, Lead Material Handler. | Sk Is A Permitted Hazardous Waste Storage And Recycling Facility. The Facility Also Sells And Leases Out Various Parts Cleaning Machines To Its Customers And Provides Servicing Of These Machines. Core Business Lines Include Parts Cleaners, Immersion Cleaners And Paint Gun Cleaners, As Well As Aqueous Cleaners (Brake And Parts Cleaners). In Addition, Sk Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps And Spent Antifreeze (Ethylene Glycol) From Its Customers. The Company Operates A Hazardous Waste Transfer Facility That Receives Wastes From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Wastes Received Or Generated At The Facility Are Stored In Containers Or Tanks. Water And Sewer Services Are Provided By The City Of Tampa. The Facility Has Not Changed Operations Since The Previous Inspection. Other Than Material Handling, The Major Process Taking Place At The Facility Is Drum Cleaning. Return/Fill Station Area The Return And Fill Area, Located Between The North And South Buildings, Is Where Drivers Pick Up The Clean Solvents In The Morning For Delivery To Customers And, In The Evening, Drop Off Spent Solvent Picked Up From The Customers That Day. Parts Washer Solvent From Customers Participating In Sk’S Continued Use Program (Cup) Is Used To Clean Returned Drums At The Sk Facility, And As Such, Is Still A Viable “Product” When Picked Up From The Customer. Cup Solvent Is Placed Into A Dedicated 200-Gallon “Continuous Use” Vat Which Is Piped To One Of Two Drum Washers/Wet Dumpsters Where It Is Spritzed Onto Brushes During The Drum Cleaning Process. Waste Generated From The Dumping And Washing Of Drums In These Dumpsters Is Placed In 55-Gallon Satellite Containers. According To Mr. Gugino The Company Is Planning On Discontinuing The Cup For Their Customers, However Waste Parts Solvent Will Continue To Be Used By Sk To Clean Drums. At The Time Of The Inspection, There Was A Satellite Drum Accumulating Facility Derived Debris (Solids). The Drum Was Closed And Labeled As A Hazardous Waste. The Secondary Containment In This Area Appeared To Be Clean, Dry And Intact. Two 6-Yard Containers Containing Aqueous Parts Washer Waste (From The Soap And Water Machines) Were Observed At The Loading Dock. The Containers Were Almost Full. Mr. Gugino Indicated This Waste Will Be Pumped Into Their Vacuum Truck And Taken To Clarke Environmental For Processing. Tank Farm After Cleaning Of The Drums, The Spent Solvent Is Pumped To The Facility’S Hazardous Waste Storage Tank, Which Is Located At The Facility’S Secondary Tank Farm. There Are Three Tanks Located Within The Tank Farm Area: A Clean 150 Mineral Spirits Tank, A Used Oil Tank, And A Dirty Parts Washer Solvent (Hazardous Waste) Tank. All Three Tanks Appear To Be In Good Working Condition And All Were Properly Labeled. The Tank Farm Is Enclosed To Minimize Rain Water In The Secondary Containment Area. At The Time Of The Inspection It Was Observed That The Fabric Cover Was Torn At Two Areas (The Top Of The North And South Sections). Mr. Gugino Indicated This Had Been Reported To Corporate And A Replacement Cover Should Be Installed In The Next Three To Four Months. The Secondary Containment Area Was Void Of Any Liquid Except For A Small Amount Of Liquid Observed In The Sump Located At The Northwest Corner. There Is An Alarm Sensor Monitor Within The Secondary Containment Area For Alerting Personnel If Liquid Is Accumulating In The Tank Farm Containment. Used Oil Is Typically Trans
05/18/2017 Informal Verbal Enforcement Compliance Assistance Offer Verbalfor InformalVerbalEnforcement-04/19/2017 ; Compliance Assistance Correspondencefor InformalVerbalEnforcement-04/20/2017 ; Finished-05/18/2017
02/20/2018 Site Inspection Routine; TSD Facility Safety-Kleen Systems, Inc., (Sk) Was Inspected On February 20, 2017, And February 23, 2018, To Determine The Facility’S Compliance With State And Federal Hazardous Waste Regulations. The Department Has Conducted Hazardous Waste Inspections At This Facility For Many Years, Most Recently On April 19, 2016. The Inspectors Were Accompanied During The Inspection By Steve Gugino, Branch General Manager, And Gerry Suarez, Material Handler. | General Facility Information: Sk Is A Permitted Hazardous Waste Storage And Recycling Facility. The Company Operates A Hazardous Waste Transfer Facility That Receives Wastes From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Wastes Received Or Generated At The Facility Are Stored In Containers Or Tanks. The Facility Has Not Changed Operations Since The Previous Inspection Except That They No Longer Offer The Continued Use Program (Cup) For Spent Parts Washer Solvent. The Facility Also Sells And Leases Out Various Parts Cleaning Machines To Its Customers And Provides Servicing Of These Machines. Core Business Lines Include Parts Cleaners, Immersion Cleaners And Paint Gun Cleaners, As Well As Aqueous Cleaners (Brake And Parts Cleaners). In Addition, Sk Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps And Spent Antifreeze (Ethylene Glycol) From Its Customers. According To Mr. Gugino, A Halogen Meter Is Used By The Drivers To Test Used Oil Collected From Their Customers Prior To Pick-Up. Seventy-Five To Eighty Percent Of Sk’S Used Oil Customers Are Automotive Repair Facilities, The Remained Are Manufacturing Accounts. Other Than Material Handling, The Major Process Taking Place At The Facility Is Drum Cleaning. Water And Sewer Services Are Provided By The City Of Tampa. Spill Response Equipment Throughout The Facility. Eyewash And Shower Stations Were Operational. Fire Extinguishers Were Charged And Are Pressure Tested Annually. Additionally, The Facility Staff Visually Checks The Fire Extinguishers And Safety Equipment Monthly. The Facility Utilizes Two Forklifts Which Are Powered By Propane. A Third Party, Florida Lift, Maintains The Forklifts. North Storage Building (Non-Flammable Storage Area): The Non-Flammable Storage Area, Located On The West Wall, Is Being Used For Empty Drum Inventory. On The East Wall Of The Building In A Caged Area For The Storage Of Re-Refined Motor And Hydraulic Oil Which Sk Began Selling In October Of 2016. This Oil Is Sold In Quart Size Containers, 5-Gallon Buckets, And 55-Gallon Drums. Samples From Each Truck Load Of Used Oil Are Retained For 90-Days In Several Closed Cabinets In This Area. At The End Of The 90-Days, These Samples Are Sent For Recycling With The Regular Used Oil. Return/Fill Station Area: Located Between The North And South Buildings, The Return And Fill Area Is Where The Drivers Of The Service Trucks Pick Up The Clean Solvents In The Morning For Delivery To Customers And Drop Off Spent Solvent Picked Up From The Customers At The End Of The Day. Sk No Longer Offers The Continued Use Program (Cup) And The Cup Vat Is No Longer In Use. Spent Parts Solvent From Drums Is Added To The Spent Parts Washer Vat. Waste Generated From The Dumping And Washing Of Spent Parts Washer Solvent Drums Is Placed In 55-Gallon Satellite Containers. At The Time Of The Inspection, There Was A Satellite Drum Accumulating Facility Derived Debris (Solids). The Drum Was Closed And Labeled As A Hazardous Waste. Two 6-Yard Containers Containing Aqueous Parts Washer Waste (From The Soap And Water Machines) Are Located On The West Side Of The Loading Dock. Containers Of Aqueous Parts Washer Waste Are Transferred To The 6-Yard Containers And Aqueous Parts Washer Waste Is Pumped Into One Of Sk’S Two Vacuum Trucks As Needed And Transported To Clarke Environmental For Processing. The Secondary Containment On Both Sides Of The Return/Fill Station Loading Dock Appeared To Be Clean, Dry And Intact. S
03/02/2018 Financial Record Reviewed-11/17/2017 ; Finished-03/02/2018
03/02/2018 Financial Record Reviewed-11/01/2017 ; Finished-03/02/2018
04/19/2018 Issue Non-Compliance Letter Compliance Assistance Offer Written-03/16/2018 ; Response Received-03/29/2018 ; Compliance Assistance Correspondence-04/18/2018 ; Finished-04/19/2018 The Compliance Assistance Offer Letter Issued On 3/16/2018 Has Been Attached In Oculus. The Response Received On 3/29/2018 Has Been Attached In Oculus. The Compliance Assistance Offer Closure/Return To Compliance Letter Was Issued On 4/18/2018 And Has Been Attached In Oculus.
03/04/2019 Financial Record Reviewed-11/17/2018 ; Finished-03/04/2019
03/04/2019 Financial Record Reviewed-11/01/2018 ; Finished-03/04/2019
02/25/2020 Site Inspection Routine; TSD Facility Safety-Kleen Systems, Inc., (Sk) Was Inspected On February 25, 2020, To Determine The Facility’S Compliance With State And Federal Hazardous Waste Regulations. The Department Has Conducted Hazardous Waste Inspections At This Facility For Many Years, Most Recently On February 23, 2018. The Inspectors Were Accompanied During The Inspection By Steve Gugino, Branch General Manager. | General Facility Information: Sk Is A Permitted Hazardous Waste Storage And Recycling Facility (Permit Number 34744-009-Ho, Issued June 12, 2017, Expires November 23, 2021). The Company Operates A Hazardous Waste Transfer Facility At This Location That Receives Wastes From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Wastes Received Or Generated At The Facility Are Stored In Containers Or Tanks. The Facility Has Not Changed Operations Since The Previous Inspection. The Facility Also Sells And Leases Out Various Parts Cleaning Machines To Its Customers And Provides Servicing Of These Machines. Core Business Lines Include Parts Cleaners, Immersion Cleaners And Paint Gun Cleaners, As Well As Aqueous Cleaners (Brake And Parts Cleaners). In Addition, Sk Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps And Spent Antifreeze (Ethylene Glycol) From Its Customers. According To Mr. Gugino, A Halogen Meter Is Used By The Drivers To Test Used Oil Collected From Their Customers Prior To Pick-Up. Seventy-Five To Eighty Percent Of Sk’S Used Oil Customers Are Automotive Repair Facilities, The Remainder Are Manufacturing Accounts. Other Than Material Handling, The Major Process Taking Place At The Facility Is Drum Cleaning. The Facility Operates From 7:00 A.M. To 5:00 P.M., Monday Through Friday. Water And Sewer Services Are Provided By The City Of Tampa. Five Used Oil Pump Trucks, One Vacuum Truck And Six Box Trucks Work Out Of This Location. The Facility Currently Employs Twenty-One People Including Two That Manage The Warehouse And Tank Farm Operations And Thirteen Drivers Which Operate The Facilities Vehicles And Handle Used Oil, Non-Hazardous And Hazardous Waste Transfers And Transportation. A Fourteenth Driver Is Scheduled To Start Within The Next Few Weeks. Used Oil Picked Up In Sk’S Used Oil Pump Trucks Is Typically Transported Directly To The Csx Yard In Tampa Where The Used Oil Is Loaded On To Railcars For Shipment To An Out-Of-State Sk Facility For Re-Refining. If Needed, Used Oil Can Be Off-Loaded Into The Used Oil Aboveground Storage Tank (Ast) At The Facility. In Addition To This Location, The Facility Has An Annex Located In Port Charlotte, Charlotte County, Florida, For The Past Twenty Years. One Box Truck And One Used Oil Pump Truck, Along With Two Of The Facility’S Drivers, Operate Out Of The Port Charlette Facility. Waste Is Not Stored At This Location, Only The Empty Trucks Following Delivery Of The Waste To Either The Tampa Facility (Typically Just The Box Truck) Or Directly To The Csx Tampa Rail Yard (Used Pump Oil Truck). Spill Response Equipment Is Staged Throughout The Facility. Eyewash And Shower Stations Were Operational. Fire Extinguishers Were Charged And Are Pressure Tested Annually. Additionally, The Facility Staff Visually Checks The Fire Extinguishers And Safety Equipment Monthly. The Facility Utilizes Two Forklifts Which Are Powered By Propane. A Third Party, Florida Lift, Maintains The Forklifts. North Storage Building (Non-Flammable Storage Area): The Non-Flammable Storage Area, Located On The West Wall, Is Being Used For Empty Drum Inventory (Both Metal And Polypropylene). A Caged Area For The Storage Of Re-Refined Motor And Hydraulic Oil Is Located On The East Wall Of The Building. This Oil Is Sold In Quart Size Containers, 5-Gallon Buckets, And 55-Gallon Drums. Samples From Each Truck Load Of Used Oil Are Retained For 90-Days In Several Closed Cabinets In This Area. At The End Of The 90-Days, These Samples Are Sent For Recycling With The Reg
03/09/2020 Financial Record Reviewed-11/17/2019 ; Finished-03/09/2020
03/09/2020 Financial Record Reviewed-11/01/2019 ; Finished-03/09/2020
05/14/2020 Electronic Communication Finished-05/14/2020
10/04/2021 Financial Record Reviewed-11/01/2020 ; Finished-10/04/2021
10/04/2021 Financial Record Reviewed-11/17/2020 ; Finished-10/04/2021
03/08/2022 Site Inspection Routine; Transporter - Routine; Transfer Facility - Routine; LQG (>1000 kg/month) - Routine; TSD Facility - Routine; Used Oil Transporter An Inspection Was Conducted At Safety-Kleen Systems Inc ("Safety-Kleen") On March 8, 2022, By The Florida Department Of Environmental Protection ("Department") To Determine The Facility'S Compliance With State And Federal Regulations For Large Quantity Generators ("Lqg") Of Hazardous Waste, Hazardous Waste And Used Oil Transporters, And Transfer Facilities. The Facility Last Notified On January 28, 2022, With Their Biennial Report. Safety-Kleen Has Been Inspected Numerous Times, Most Recently On February 25, 2020. Inspectors Were Assisted By Jamie Stanley, Branch General Manager, During The Inspection. | At The Time Of The Inspection, Safety-Kleen Systems Inc Was Operating In Compliance With State And Federal Regulations For Large Quantity Generators Of Hazardous Waste, Hazardous Waste And Used Oil Transporters, And Transfer Facilities. | Safety-Kleen Is A Permitted Hazardous Waste Storage And Recycling Facility (Permit Number 34744-010-Ho, Issued August 18, 2021, Expires November 23, 2026). The Company Operates A Hazardous Waste Transfer Facility At This Location That Receives Wastes From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Wastes Received Or Generated At The Facility Are Stored In Containers Or Tanks. The Facility Has Not Changed Operations Since The Previous Inspection. The Facility Is On City Of Tampa Water And Sewer. Incoming The Incoming Storage Area, Located On The West Wall, Is Being Used For Empty Drum Inventory (Both Metal And Polypropylene). A Caged Area For The Storage Of Re-Refined Motor And Hydraulic Oil Is Located On The East Wall Of The Building. This Oil Is Sold In Quart Size Containers, 5-Gallon Buckets, And 55-Gallon Drums. Samples From Each Truck Load Of Used Oil Are Retained For 90-Days In Several Closed Cabinets In This Area. At The End Of The 90-Days, These Samples Are Sent For Recycling With The Regular Used Oil. At The Time Of The Inspection, There Was One 55-Gallon Metal Drum For Oil Samples Past Retention Time Labeled "Used Oil". The Facility Also Sells And Leases Out Various Parts Washer Machines To Its Customers And Provides Servicing Of These Machines. Core Business Lines Include Parts Washers, Immersion Cleaners And Paint Gun Cleaners, As Well As Aqueous Cleaners (Brake And Parts Cleaners). These Products Are All Stored Within The Incoming Storage Area. Dump + Fill Located Between The North And South Buildings, The Dump And Fill Area Is Where The Drivers Of The Service (Box) Trucks Pick Up The Clean Solvents In The Morning For Delivery To Customers And Drop Off Spent Solvent Picked Up From The Customers At The End Of The Day. Warehouse Staff Off-Load The Box Trucks And Move Waste Containers (Other Than Spent Parts Washer Fluids) Into The Warehouse For Storage. Spent Parts Washer Solvent From Drums Is Deposited Into One Of The Two Metal Spent Parts Washer Vats. A Third Vat Is Present But Unusable. The Spent Parts Washer Vats Are Approximately 540 Gallons In Size (6 Foot By 3 Foot By 4 Foot) And Are Plumbed With Fixed Metal Piping To The Dirty Parts Washer Solvent Ast. Solid Waste Generated From The Dumping And Washing Of Spent Parts Washer Solvent Drums Is Placed Into A Satellite Container; Liquid Waste Is Routed Through The Spent Parts Washer Vats To The Dirty Parts Washer Solvent Ast. At The Time Of The Inspection, Located In This Area Were: • One 35-Gallon Drum Of Flammable Solids • One 55-Gallon Drum Of Flammable Liquids • Ten 275-Gallon Totes Of Used Antifreeze • Ten Containers Of Used Oil Filters. All Containers Were Properly Labeled As Required. No Container Leaks Or Spills Were Observed. Tank Farm There Are Three 14,250-Gallon Aboveground Storage Tanks (Asts) Located Within The Tank Farm Area: A Clean 150 Mineral Spirits Ast, A Used Oil Ast, And A Dirty Parts Washer Solvent (Hazardous Waste) Ast. The Contents Of The Spent Vat In The Dump + Fill Station Area Is Pumped To The Facility’S Dirty Parts Washer Solvent Ast. If Needed The On-Site
01/09/2023 Financial Record Reviewed-11/01/2021 ; Finished-01/09/2023
03/01/2023 Financial Record Reviewed-02/15/2023 ; Finished-03/01/2023
05/26/2023 Site Inspection Routine; LQG (>1000 kg/month) - Routine; TSD Facility - Routine; Hazardous Waste Transporter - Routine; Used Oil Transporter - Routine; Hazardous Waste Transfer Facility - Routine; Used Oil Transfer Facility Safety-Kleen Systems, Inc. (Safety-Kleen Tampa), Was Inspected By The Florida Department Of Environmental Protection (Department) On May 31, 2023, To Determine The Facility'S Compliance With State And Federal Regulations For Large Quantity Generators ("Lqg") Of Hazardous Waste; Hazardous Waste And Used Oil Transporters, And Hazardous Waste Transfer Facilities. The Facility Most Recently Updated Their Notification On March 1, 2023. Safety-Kleen Tampa Has Been Inspected Numerous Times, Most Recently On March 8, 2022. Inspectors Were Assisted By Jose Reyes, Service Delivery Manager; Michelle Musgrave, Lead Branch Administrator; And Jamie Stanley, Branch Manager, During The Inspection. Permits And Registrations • Hazardous Waste Storage And Recycling Facility Permit: Permit Number 34744-010-Ho, Which Was Issued On August 18, 2021, And Expires On November 23, 2026. • Hazardous Waste Transporter Registration: The Current Registration Was Issued On March 4, 2022, And Expires On June 30, 2023. The Next Year’S Annual Registration Was Issued On March 13, 2023, And Expires On June 30, 2024. • Used Oil Transporter Registration: The Current Registration Was Issued On February 8, 2022, And Expires On June 30, 2023. The Next Year’S Annual Registration Was Issued On March 9, 2023, And Expires On June 30, 2024. | Safety-Kleen Tampa Is A Hazardous Waste And Used Oil Transporter, And Hazardous Waste Transfer Facility. The Facility Operates From 7:00 A.M. To 5:00 P.M., Monday Through Friday. The Facility Currently Employs Twenty-One People Including Two That Manage The Warehouse And Tank Farm Operations And Thirteen Drivers Which Operate The Facilities Vehicles And Handle Used Oil, Non-Hazardous And Hazardous Waste Transfers, And Transportation. The Facility Is On City Of Tampa Water And Sewer. Safety-Kleen Operates A Hazardous Waste Transfer Facility At This Location That Receives Waste From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Waste Received Or Generated At The Facility Is Stored In Containers Or Tanks. In Addition, Safety-Kleen Tampa Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps, And Spent Antifreeze (Ethylene Glycol) From Its Customers. According To Jose Reyes, A Halogen Meter Is Used By The Drivers To Test Used Oil Collected From Their Customers Prior To Pick-Up. Seventy-Five To Eighty Percent Of Safety-Kleen Tampa’S Used Oil Customers Are Automotive Repair Facilities, The Remainder Are Manufacturing Accounts. Five Used Oil Pump Trucks, One Vacuum Truck And Six Box Trucks Work Out Of This Location. Used Oil Picked Up In Safety-Kleen Tampa’S Used Oil Pump Trucks Is Typically Transported Directly To The Csx Yard In Tampa Where The Used Oil Is Loaded On To Railcars For Shipment To An Out-Of-State Safety-Kleen Facility For Re-Refining. If Needed, Used Oil Can Be Off-Loaded Into The Used Oil Aboveground Storage Tank (Ast) At The Facility. In Addition To This Location, The Facility Has An Annex Located In Port Charlotte, Charlotte County, Florida, For The Past Twenty Years. One Box Truck And One Used Oil Pump Truck, Along With Two Of The Facility’S Drivers, Operate Out Of The Port Charlette Facility. Waste Is Not Stored At The Port Charlette Location, Only The Empty Trucks Following Delivery Of The Waste To Either The Tampa Facility (Typically Just The Box Truck) Or Directly To The Csx Tampa Rail Yard (Used Pump Oil Truck). Spill Response Equipment Is Staged Throughout The Facility. Eyewash And Shower Stations Were Operational. Fire Extinguishers Were Charged And Are Pressure Tested Annually. Additionally, The Facility Staff Visually Checks The Fire Extinguishers And Safety Equipment Monthly. The Facility Utilizes Two Forklifts Which Are Powered By Propane. A Third Party, Toyota Forklift, Maintains The Forklifts. Other Than Material Handling, The Major Process Taking Place At The Facility Is Drum Cleaning. The Facility Has Not Changed Operations Since
02/22/2024 Site Inspection Routine; Transporter - Routine; Transfer Facility - Routine; Used Oil-Other - Routine; LQG (>1000 kg/month) - Routine; TSD Facility Safety-Kleen Systems, Inc. (Safety-Kleen Tampa), Was Inspected By The Florida Department Of Environmental Protection (Department) On February 22, 2024, To Determine The Facility'S Compliance With State And Federal Regulations For Large Quantity Generators ("Lqg") Of Hazardous Waste; Hazardous Waste And Used Oil Transporters, And Hazardous Waste Transfer Facilities. The Facility Most Recently Updated Their Notification On March 1, 2023. Safety-Kleen Tampa Has Been Inspected Numerous Times, Most Recently On May 31, 2023. Inspectors Were Assisted By Jose Reyes, Service Delivery Manager And Jamie Stanley, Branch Manager, During The Inspection. Permits And Registrations • Hazardous Waste Storage And Recycling Facility Permit: Permit Number 34744-010-Ho, Which Was Issued On August 18, 2021, And Expires On November 23, 2026. • Hazardous Waste Transporter Registration: The Current Registration Was Issued On March 13, 2023, And Expires On June 30, 2024. • Used Oil Transporter Registration: The Current Registration Was Issued On March 9, 2023, And Expires On June 30, 2024. | Safety-Kleen Tampa Is A Hazardous Waste And Used Oil Transporter, And Hazardous Waste Transfer Facility. The Facility Operates From 7:00 A.M. To 5:00 P.M., Monday Through Friday. The Facility Currently Employs Twenty-One People Including Two That Manage The Warehouse And Tank Farm Operations And Thirteen Drivers Which Operate The Facilities Vehicles And Handle Used Oil, Non-Hazardous And Hazardous Waste Transfers, And Transportation. The Facility Is On City Of Tampa Water And Sewer. Safety-Kleen Operates A Hazardous Waste Transfer Facility At This Location That Receives Waste From Its Customers For Consolidation And Shipment To Other Facilities. All Hazardous Waste Received Or Generated At The Facility Is Stored In Containers Or Tanks. In Addition, Safety-Kleen Tampa Collects Used Oil And Used Oil Filters, Spent Mercury-Containing Lamps, And Spent Antifreeze (Ethylene Glycol) From Its Customers. According To Jose Reyes, A Halogen Meter Is Used By The Drivers To Test Used Oil Collected From Their Customers Prior To Pick-Up. Seventy-Five To Eighty Percent Of Safety-Kleen Tampa’S Used Oil Customers Are Automotive Repair Facilities, The Remainder Are Manufacturing Accounts. Five Used Oil Pump Trucks, One Vacuum Truck And Six Box Trucks Work Out Of This Location. Used Oil Picked Up In Safety-Kleen Tampa’S Used Oil Pump Trucks Is Typically Transported Directly To The Csx Yard In Tampa Where The Used Oil Is Loaded On To Railcars For Shipment To An Out-Of-State Safety-Kleen Facility For Re-Refining. If Needed, Used Oil Can Be Off-Loaded Into The Used Oil Aboveground Storage Tank (Ast) At The Facility. In Addition To This Location, The Facility Has An Annex Located In Port Charlotte, Charlotte County, Florida, For The Past Twenty Years. One Box Truck And One Used Oil Pump Truck, Along With Two Of The Facility’S Drivers, Operate Out Of The Port Charlette Facility. Waste Is Not Stored At The Port Charlette Location, Only The Empty Trucks Following Delivery Of The Waste To Either The Tampa Facility (Typically Just The Box Truck) Or Directly To The Csx Tampa Rail Yard (Used Pump Oil Truck). Spill Response Equipment Is Staged Throughout The Facility. Eyewash And Shower Stations Were Operational. Fire Extinguishers Were Charged And Are Pressure Tested Annually. Additionally, The Facility Staff Visually Checks The Fire Extinguishers And Safety Equipment Monthly. The Facility Utilizes Two Forklifts Which Are Powered By Propane. A Third Party, Toyota Forklift, Maintains The Forklifts. Other Than Material Handling, The Major Process Taking Place At The Facility Is Drum Cleaning. The Facility Has Not Changed Operations Since The Previous Inspection. North Storage Building (Non-Flammable Storage Area): The Non-Flammable Storage Area, Located On The West Wall, Is Being Used For Empty Drum Inventory (Both Metal And Polypropylene). A Caged Area For The Storage
02/27/2024 Informal Verbal Enforcement Finished-05/26/2023 ; Finished-02/27/2024
03/18/2024 Financial Record Reviewed-01/15/2024 ; Finished-03/18/2024
03/19/2024 Informal Verbal Enforcement Return to Compliance Letter Sent (RCL)-03/19/2024 ; Finished-03/19/2024

Violation History:

Vio# Area Regulation Opened By Date Determined Completed ETA Act Act Date Regulation Text Excerpt
(mouse over for full text)
1 264.H 264.140(a) Raney_M 07/06/1989 03/27/1996 4643 07/06/1989 The requirements of 264.142, 264.143, and 264.147 through 264.151 apply to owners and operators of all hazardous waste facilities, except as provided otherwise in this section or in 264.1.
2 268.A 268.1(a) Gilyard_D 03/06/1990 04/20/1990 4642 03/06/1990 This part identifies hazardous wastes that are restricted from land disposal and defines those limited circumstances under which an otherwise prohibited waste may continue to be land disposed.
3 268.A 268.1(b) Gilyard_D 03/06/1990 04/20/1990 4642 03/06/1990 Except as specifically provided otherwise in this part or part 261 of this chapter, the requirements of this part apply to persons who generate or transport hazardous waste and owners and operators of hazardous waste treatment, storage, and disposal
4 264.H 264.140(a) Chaz_Load 04/20/1990 05/30/1990 4641 04/20/1990 The requirements of 264.142, 264.143, and 264.147 through 264.151 apply to owners and operators of all hazardous waste facilities, except as provided otherwise in this section or in 264.1.
5 264.1 Raney_M 06/19/1990 03/27/1996 4620 06/19/1990 Purpose, scope and applicability.
6 264.1 Raney_M 06/19/1990 03/27/1996 4620 06/19/1990 Purpose, scope and applicability.
8 268.A 268.1(b) Crawford_W 06/19/1990 07/14/1991 4621 06/19/1990 Except as specifically provided otherwise in this part or part 261 of this chapter, the requirements of this part apply to persons who generate or transport hazardous waste and owners and operators of hazardous waste treatment, storage, and disposal
9 264.1 Crawford_W 06/19/1990 07/14/1991 4621 06/19/1990 Purpose, scope and applicability.
11 264.I 264.170 Chaz_Load 08/03/1990 07/18/1991 4620 06/19/1990 Applicability. The regulations in this subpart apply to owners and operators of all hazardous waste facilities that store containers of hazardous waste, except as 264.1 provides otherwise. [ Comment: Under 261.7 and 261.33(c), if a hazardous waste i
12 264.I 264.190 Chaz_Load 08/03/1990 07/18/1991 4620 06/19/1990 Applicability. The requirements of this subpart apply to owners and operators of facilities that use tank systems for storing or treating hazardous waste except as otherwise provided in paragraphs (a), (b), and (c) of this section or in 264.1 of this
13 264.I 264.170 Chaz_Load 08/03/1990 07/18/1991 4620 06/19/1990 Applicability. The regulations in this subpart apply to owners and operators of all hazardous waste facilities that store containers of hazardous waste, except as 264.1 provides otherwise. [ Comment: Under 261.7 and 261.33(c), if a hazardous waste i
14 264.1 Chaz_Load 08/03/1990 07/18/1991 4620 06/19/1990 Purpose, scope and applicability.
10 264.H 264.140(a) Chaz_Load 05/03/1991 06/12/1991 4619 05/03/1991 The requirements of 264.142, 264.143, and 264.147 through 264.151 apply to owners and operators of all hazardous waste facilities, except as provided otherwise in this section or in 264.1.
15 264.H 264.140(a) Chaz_Load 10/12/1992 10/26/1992 4618 10/12/1992 The requirements of 264.142, 264.143, and 264.147 through 264.151 apply to owners and operators of all hazardous waste facilities, except as provided otherwise in this section or in 264.1.
16 XXS 62-730.171(2) Chaz_Load 11/17/1993 11/17/1993 4617 11/10/1993 A transfer facility used for storage of hazardous waste for more than 24 hours but 10 days or less shall comply with the following requirements all as adopted by reference in subsection 62-730.180(2), F.A.C., except where otherwise noted:
19 268.A 268.7 Chaz_Load 12/21/1994 02/01/1995 1558 11/10/1994 Testing, tracking, and recordkeeping requirements for generators, treaters, and disposal facilities.
20 264.E 264.73(b)(1) Chaz_Load 12/21/1994 02/01/1995 1558 11/10/1994 A description and the quantity of each hazardous waste received, and the method(s) and date(s) of its treatment, storage, or disposal at the facility as required by appendix I of this part. This information must be maintained in the operating record
21 XXS 62-730.171 Chaz_Load 12/21/1994 02/01/1995 1558 11/10/1994 Transfer Facilities.
22 268 Chaz_Load 01/04/1996 03/06/1996 2079 11/29/1995 PART 268-LAND DISPOSAL RESTRICTIONS
23 PCR 403.727(1)(c) Chaz_Load 01/04/1996 03/06/1996 2079 11/29/1995 Fail to comply with a permit;
24 264.73 Chaz_Load 01/04/1996 03/06/1996 2079 11/29/1995 Operating record.
25 264.D 264.53 Chaz_Load 01/04/1996 03/06/1996 2079 11/29/1995 Copies of contingency plan. A copy of the contingency plan and all revisions to the plan must be:
26 268.A 268.7 Chaz_Load 01/04/1996 03/06/1996 2079 11/29/1995 Testing, tracking, and recordkeeping requirements for generators, treaters, and disposal facilities.
27 262.B 262.20 Chaz_Load 01/04/1996 03/06/1996 2079 11/29/1995 General requirements.
28 XXS 62-730.171(2)(e) Chaz_Load 01/04/1996 03/06/1996 2079 11/29/1995 The owner or operator of a transfer facility shall maintain a written record of when all hazardous waste enters and leaves the facility. This record shall include the generator's name, the generator's EPA/DEP identification number, and the manifest n
29 UNKNOWN Knauss_B 10/31/1996 10/31/1996 5745 10/31/1996 Unknown - insufficient data from import to identify rule.
30 268.E 268.50(a)(2)(i) Knauss_B 10/31/1996 10/31/1996 5745 10/31/1996 Each container is clearly marked to identify its contents and the date each period of accumulation begins;
31 262.D 262.40(a) Knauss_B 10/31/1996 10/31/1996 5745 10/31/1996 A generator must keep a copy of each manifest signed in accordance with 262.23(a) for three years or until he receives a signed copy from the designated facility which received the waste. This signed copy must be retained as a record for at least thr
32 268.A 268.7(a)(1) Knauss_B 10/31/1996 10/31/1996 5745 10/31/1996 A generator of hazardous waste must determine if the waste has to be treated before it can be land disposed. This is done by determining if the hazardous waste meets the treatment standards in 268.40, 268.45, or 268.49. This determination can be made
33 268.A 268.7(a)(1) Knauss_B 10/31/1996 10/31/1996 5745 10/31/1996 A generator of hazardous waste must determine if the waste has to be treated before it can be land disposed. This is done by determining if the hazardous waste meets the treatment standards in 268.40, 268.45, or 268.49. This determination can be made
34 268.A 268.7(a)(1) Knauss_B 10/31/1996 12/26/1996 5745 10/31/1996 A generator of hazardous waste must determine if the waste has to be treated before it can be land disposed. This is done by determining if the hazardous waste meets the treatment standards in 268.40, 268.45, or 268.49. This determination can be made
35 264.B 264.15(d) Knauss_B 10/31/1996 10/31/1996 5745 10/31/1996 The owner or operator must record inspections in an inspection log or summary. He must keep these records for at least three years from the date of inspection. At a minimum, these records must include the date and time of the inspection, the name of
36 264.B 264.15(b)(1) Knauss_B 10/31/1996 10/31/1996 5745 10/31/1996 The owner or operator must develop and follow a written schedule for inspecting monitoring equipment, safety and emergency equipment, security devices, and operating and structural equipment (such as dikes and sump pumps) that are important to preven
37 XXS 62-730.171(2)(e) Dregne_J 06/25/1998 06/25/1998 7017 06/25/1998 The owner or operator of a transfer facility shall maintain a written record of when all hazardous waste enters and leaves the facility. This record shall include the generator's name, the generator's EPA/DEP identification number, and the manifest n
38 264.E 264.73(b)(1) Dregne_J 06/25/1998 09/30/1998 7017 06/25/1998 A description and the quantity of each hazardous waste received, and the method(s) and date(s) of its treatment, storage, or disposal at the facility as required by appendix I of this part. This information must be maintained in the operating record
39 264.16 Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 Personnel training.
40 264.C 264.31 Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 Design and operation of facility. Facilities must be designed, constructed, maintained, and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to
41 264.C 264.33 Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 Testing and maintenance of equipment. All facility communications or alarm systems, fire protection equipment, spill control equipment, and decontamination equipment, where required, must be tested and maintained as necessary to assure its proper ope
42 264.E 264.73(b)(1) Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 A description and the quantity of each hazardous waste received, and the method(s) and date(s) of its treatment, storage, or disposal at the facility as required by appendix I of this part. This information must be maintained in the operating record
43 264.I 264.171 Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 Condition of containers. If a container holding hazardous waste is not in good condition (e.g., severe rusting, apparent structural defects) or if it begins to leak, the owner or operator must transfer the hazardous waste from this container to a co
44 264.I 264.175(b)(1) Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 A base must underlie the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation until the collected material is detected and removed;
45 268.5 Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 Procedures for case-by-case extensions to an effective date.
46 XXS 62-730.171(2)(e) Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 The owner or operator of a transfer facility shall maintain a written record of when all hazardous waste enters and leaves the facility. This record shall include the generator's name, the generator's EPA/DEP identification number, and the manifest n
47 XXS 62-701.300(1) Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 General prohibition.
48 XXS 62-701.300(1) Dregne_J 06/17/1999 09/28/1999 7238 06/17/1999 General prohibition.
49 264.B 264.16(c) Knauss_B 04/20/2000 05/24/2000 7654 04/20/2000 Facility personnel must take part in an annual review of the initial training required in paragraph (a) of this section.
50 264.C 264.31 Knauss_B 04/20/2000 04/20/2000 7654 04/20/2000 Design and operation of facility. Facilities must be designed, constructed, maintained, and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to
51 279.E 279.45(g) Knauss_B 04/20/2000 05/24/2000 7654 04/20/2000 Labels.
52 XXS 62-710 Knauss_B 04/20/2000 05/24/2000 7654 04/20/2000 CHAPTER 62-710 USED OIL MANAGEMENT
53 262.B 262.20(a) Dregne_J 03/13/2001 05/24/2001 8165 03/13/2001 Rule Description not available
54 264.15 Dregne_J 03/13/2001 05/24/2001 8165 03/13/2001 General inspection requirements. [ Comment: Part 270 of this chapter requires the inspection schedule to be submitted with part B of the permit application. EPA will evaluate the schedule along with the rest of the application to ensure that it adeq
55 264.C 264.31 Dregne_J 03/13/2001 05/24/2001 8165 03/13/2001 Design and operation of facility. Facilities must be designed, constructed, maintained, and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to
56 264.E 264.73(b)(1) Dregne_J 03/13/2001 05/24/2001 8165 03/13/2001 A description and the quantity of each hazardous waste received, and the method(s) and date(s) of its treatment, storage, or disposal at the facility as required by appendix I of this part. This information must be maintained in the operating record
57 XXS 62-730.171(2)(e) Dregne_J 03/13/2001 05/24/2001 8165 03/13/2001 The owner or operator of a transfer facility shall maintain a written record of when all hazardous waste enters and leaves the facility. This record shall include the generator's name, the generator's EPA/DEP identification number, and the manifest n
58 XXS 62-701.300(1) Dregne_J 03/13/2001 05/24/2001 8165 03/13/2001 General prohibition.
59 XXS 62-701.300(1) Dregne_J 03/13/2001 08/20/2001 8165 03/13/2001 General prohibition.
60 XXS 62-701.300(1) Dregne_J 03/13/2001 08/20/2001 8165 03/13/2001 General prohibition.
61 XXS 62-701.300(1) Dregne_J 03/13/2001 08/20/2001 8165 03/13/2001 General prohibition.
62 264.B 264.15(b)(1) Knauss_B 01/10/2002 03/15/2002 8612 01/10/2002 The owner or operator must develop and follow a written schedule for inspecting monitoring equipment, safety and emergency equipment, security devices, and operating and structural equipment (such as dikes and sump pumps) that are important to preven
63 264.B 264.15(c) Knauss_B 01/10/2002 04/30/2002 8612 01/10/2002 The owner or operator must remedy any deterioration or malfunction of equipment or structures which the inspection reveals on a schedule which ensures that the problem does not lead to an environmental or human health hazard. Where a hazard is immine
64 264.B 264.15(d) Knauss_B 01/10/2002 03/15/2002 8612 01/10/2002 The owner or operator must record inspections in an inspection log or summary. He must keep these records for at least three years from the date of inspection. At a minimum, these records must include the date and time of the inspection, the name of
65 264.C 264.31 Knauss_B 01/10/2002 03/15/2002 8612 01/10/2002 Design and operation of facility. Facilities must be designed, constructed, maintained, and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to
66 264.I 264.175(b)(1) Knauss_B 01/10/2002 05/30/2002 8612 01/10/2002 A base must underlie the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation until the collected material is detected and removed;
67 264.E 264.73(b)(1) Gephart_A 05/29/2003 07/14/2003 9450 05/29/2003 A description and the quantity of each hazardous waste received, and the method(s) and date(s) of its treatment, storage, or disposal at the facility as required by appendix I of this part. This information must be maintained in the operating record
68 264.CC 264.1084(c)(4)(ii) Gephart_A 05/29/2003 05/30/2003 9450 05/29/2003 The owner or operator shall perform an initial inspection of the fixed roof and its closure devices on or before the date that the tank becomes subject to this section. Thereafter, the owner or operator shall perform the inspections at least once eve
69 279.E 279.45(d) Gephart_A 05/29/2003 07/14/2003 9450 05/29/2003 Secondary containment for containers. Containers used to store used oil at transfer facilities must be equipped with a secondary containment system.
70 279.E 279.44(a) Dregne_J 02/04/2004 10/03/2005 9868 02/04/2004 To ensure that used oil is not a hazardous waste under the rebuttable presumption of 279.10(b)(1)(ii), the used oil transporter must determine whether the total halogen content of used oil being transported or stored at a transfer facility is above o
71 279.E 279.44(d) Dregne_J 02/04/2004 10/03/2005 9868 02/04/2004 Record retention. Records of analyses conducted or information used to comply with paragraphs (a), (b), and (c) of this section must be maintained by the transporter for at least 3 years.
72 XXS 62-710.600(2)(b) Dregne_J 02/04/2004 08/02/2004 9868 02/04/2004 Show evidence of familiarity with applicable state laws and rules governing used oil transportation by submitting a training program for approval to the Department which includes provisions for at least the following:
73 XXS 62-770.250 Gephart_A 03/14/2005 03/14/2005 10524 03/14/2005 Contamination Reporting. Upon discovery of contamination (unless the contamination is the result of a previously reported discharge for which site rehabilitation completion has not been achieved or the contamination is known to be from a non-petroleu
74 XXS 62-737 Gephart_A 03/14/2005 03/14/2005 10524 03/14/2005 CHAPTER 62-737 THE MANAGEMENT OF SPENT MERCURY-CONTAINING LAMPS AND DEVICES DESTINED FOR RECYCLING
75 XXS 62-737 Gephart_A 03/14/2005 03/14/2005 10524 03/14/2005 CHAPTER 62-737 THE MANAGEMENT OF SPENT MERCURY-CONTAINING LAMPS AND DEVICES DESTINED FOR RECYCLING
76 XXS 62-770.250 Gephart_A 01/19/2006 01/19/2006 11091 01/19/2006 Contamination Reporting. Upon discovery of contamination (unless the contamination is the result of a previously reported discharge for which site rehabilitation completion has not been achieved or the contamination is known to be from a non-petroleu
77 XXS 62-737.400(5)(a) Honey_K 07/20/2007 07/20/2007 12026 07/20/2007 Fragile universal waste devices, universal waste lamps crushed per paragraph (6)(b) below, and lamps or devices showing evidence of leakage, spillage, or damage that could cause leakage, shall be placed in closed containers that are structurally soun
78 XXS 62-737.400(5)(b)1 Honey_K 07/20/2007 07/20/2007 12026 07/20/2007 For universal waste lamps, the words "Spent Mercury-Containing Lamps for Recycling", "Universal Waste Mercury Lamps", "Waste Mercury Lamps" or "Used Mercury Lamps"; except for those crushed per paragraph (6)(b) below which shall be labeled "Crushed M
79 62-710.510(1)(g) Honey_K 07/20/2007 07/20/2007 12026 07/20/2007 Documentation of halogen screening in accordance with the requirements of Rule 62-710.600, F.A.C.
80 264.I 264.171 Honey_K 08/28/2008 08/28/2008 12854 08/28/2008 Condition of containers. If a container holding hazardous waste is not in good condition (e.g., severe rusting, apparent structural defects) or if it begins to leak, the owner or operator must transfer the hazardous waste from this container to a co
81 264.B 264.16(d) Honey_K 08/28/2008 08/28/2008 12854 08/28/2008 The owner or operator must maintain the following documents and records at the facility:
82 264.D 264.51(a) Honey_K 08/28/2008 08/28/2008 12854 08/28/2008 Each owner or operator must have a contingency plan for his facility. The contingency plan must be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous wast
83 264.D 264.52(e) Honey_K 09/30/2009 11/03/2009 19758 140000000100021 09/30/2009 The plan must include a list of all emergency equipment at the facility (such as fire extinguishing systems, spill control equipment, communications and alarm systems (internal and external), and decontamination equipment), where this equipment is re
98 XXS 62-710.401(6) Honey_K 09/30/2009 11/03/2009 140000000100021 09/30/2009 No person may store used oil in tanks or containers unless they are clearly labeled with the words "used oil" and are in good condition (no severe rusting, apparent structural defects or deterioration) with no visible oil leakage. If tanks or contain
84 PCR 403.727(1)(c) Honey_K 08/20/2010 11/09/2010 27533 140000000100256 08/20/2010 Fail to comply with a permit;
85 XXS 62-710.401(6) Honey_K 08/20/2010 11/09/2010 27533 140000000100256 08/20/2010 No person may store used oil in tanks or containers unless they are clearly labeled with the words "used oil" and are in good condition (no severe rusting, apparent structural defects or deterioration) with no visible oil leakage. If tanks or contain
86 279.C 279.22(d)(3) Honey_K 08/20/2010 11/09/2010 27533 140000000100256 08/20/2010 Clean up and manage properly the released used oil and other materials; and
99 268.E 268.50(a)(2)(i) Honey_K 08/20/2010 11/09/2010 140000000100256 08/20/2010 Each container is clearly marked to identify its contents and the date each period of accumulation begins;
100 263.A 263.12 Honey_K 08/20/2010 11/09/2010 140000000100256 08/20/2010 Transfer facility requirements. A transporter who stores manifested shipments of hazardous waste in containers meeting the requirements of 262.30 at a transfer facility for a period of ten days or less is not subject to regulation under parts 270, 26
101 264.C 264.35 Honey_K 08/20/2010 11/09/2010 140000000100256 08/20/2010 Required aisle space. The owner or operator must maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, spill control equipment, and decontamination equipment to any area of facility operation in an emergency
87 263.B 263.20 Knauss_E 08/09/2011 10/13/2011 154528 55000000100760 08/09/2011 The manifest system.
88 264.B, XXS 264.16(a)(1), 403.727(1)(a) Knauss_E 08/09/2011 10/13/2011 154528 55000000100760 08/09/2011 Facility personnel must successfully complete a program of classroom instruction or on-the-job training that teaches them to perform their duties in a way that ensures the facility's compliance with the requirements of this part. The owner or operato
89 264.J 264.192(e) Knauss_E 08/09/2011 10/13/2011 154528 55000000100760 08/09/2011 Ancillary equipment must be supported and protected against physical damage and excessive stress due to settlement, vibration, expansion, or contraction. [Note: The piping system installation procedures described in American Petroleum Institute (API
90 264.C 264.31 Knauss_E 08/09/2011 09/13/2011 154528 55000000100760 08/09/2011 Design and operation of facility. Facilities must be designed, constructed, maintained, and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to
91 264.B 264.15(d) Knauss_E 08/09/2011 10/13/2011 154528 55000000100760 08/09/2011 The owner or operator must record inspections in an inspection log or summary. He must keep these records for at least three years from the date of inspection. At a minimum, these records must include the date and time of the inspection, the name of
102 264.BB 264.1050(d) Knauss_E 08/09/2011 10/13/2011 55000000100760 08/09/2011 Each piece of equipment to which this subpart applies shall be marked in such a manner that it can be distinguished readily from other pieces of equipment.
103 264.C 264.33 Knauss_E 08/09/2011 10/13/2011 55000000100760 08/09/2011 Testing and maintenance of equipment. All facility communications or alarm systems, fire protection equipment, spill control equipment, and decontamination equipment, where required, must be tested and maintained as necessary to assure its proper ope
104 270.B 270.14(d)(1) Knauss_E 08/09/2011 10/13/2011 55000000100760 08/09/2011 The following information is required for each solid waste management unit at a facility seeking a permit:
105 PCR 403.727(1)(c) Knauss_E 07/17/2012 07/17/2012 161078 07/17/2012 Fail to comply with a permit;
92 XXS 403.727(1)(a) Evans_R 08/25/2015 12/02/2015 175962 08/25/2015 Fail to comply with the provisions of this act or departmental rules or orders;
93 XXS 403.727(1)(a) Evans_R 08/25/2015 12/02/2015 175962 08/25/2015 Fail to comply with the provisions of this act or departmental rules or orders;
94 264.C 264.35 Evans_R 08/25/2015 12/02/2015 175962 08/25/2015 Required aisle space. The owner or operator must maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, spill control equipment, and decontamination equipment to any area of facility operation in an emergency
95 279.E 279.43(b) Evans_R 08/25/2015 12/02/2015 175962 08/25/2015 DOT Requirements. Used oil transporters must comply with all applicable requirements under the U.S. Department of Transportation regulations in 49 CFR parts 171 through 180. Persons transporting used oil that meets the definition of a hazardous mater
96 XXS 62-710.401(6) Evans_R 08/25/2015 12/02/2015 175962 08/25/2015 No person may store used oil in tanks or containers unless they are clearly labeled with the words "used oil" are in good condition (no severe rusting, apparent structural defects or deterioration), and not leaking (no visible leaks). If tanks or con
97 PCR 403.727(1)(c) Evans_R 04/19/2017 04/20/2017 180145 04/19/2017 Fail to comply with a permit;
106 279.E 279.46(b)(5)(i) Pedigo_L 02/20/2018 03/29/2018 182122 02/20/2018 Except as provided in paragraph (b)(5)(ii) of this section, the signature, dated upon receipt of the used oil, of a representative of the receiving facility or transporter.
107 264.E 264.76(a) Pedigo_L 02/20/2018 03/29/2018 182122 02/20/2018 If a facility accepts for treatment, storage, or disposal any hazardous waste from an off-site source without an accompanying manifest, or without an accompanying shipping paper as described by 263.20(e) of this chapter, and if the waste is not exclu
108 262.A 262.15(a)(5)(ii) Pedigo_L 05/26/2023 05/26/2023 195360 05/26/2023 A generator must mark or label its SAA containers with an indication of the hazards of the contents (examples include, but are not limited to, the applicable hazardous waste characteristic(s) (i.e., ignitable, corrosive, reactive, toxic); hazard comm
109 262.A 262.17(a)(5)(i)(B) Enck_M 02/22/2024 02/22/2024 197038 02/22/2024 Label or mark each LQG container with an indication of the hazards of the contents